Defect No | Defect Type | Regulation | Defect Description | Defect Category |
641231
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.4.5.2.4
|
Wiring systems - Wiring enclosures for the wiring system - Wiring system between non-adjacent groups of PV modules
|
Technical
|
821065
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
2.6.2
|
Switchboards - Accessibility
|
Technical
|
631088
|
AS/NZS 4777.2:2020 +A1 Grid connection of energy systems via inverters Inverter requirements
|
4.5.3.2.2
|
Response to a decrease in frequency - Response to a decrease in frequency for mulltiple mode inverters with energy stora ge
|
Technical
|
821102
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
3.5.2.2.3
|
Event wiring systems - Keyed single pole connectors construction
|
Technical
|
821135
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
3.7.4.4.2
|
Electrical accessories for events - Outlet boxes - Overcurrent protection - Rating
|
Technical
|
631084
|
AS/NZS 4777.2:2020 +A1 Grid connection of energy systems via inverters Inverter requirements
|
4.5.1
|
Limits for sustained operation - General
|
Technical
|
641276
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
5.6.1
|
Recording of solar system layout - General
|
Technical
|
641196
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.3.5.3.1
|
load break disconnection device - General
|
Technical
|
211920
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.6.3.2.5
|
Additional protection by residual current devices - Alterations to installations and replacement of switchboards
|
Technical
|
821131
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
3.7.4.1
|
Electrical accessories for events - Outlet boxes - General
|
Technical
|
641199
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.3.6.1
|
Selection of overcurrent protection - General
|
Technical
|
641067
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
2.1.4.2
|
Use of PCE with multiple d.c. inputs - PCEs with separate maximum power point tracking (MPPT) inputs
|
Technical
|
821063
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
2.6.1
|
Switchboards - General
|
Technical
|
641081
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
4.3.5.1
|
Disconnecting devices - General
|
Technical
|
821106
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
3.5.6.1
|
Event wiring systems - Cables supported by a catenary - Types of cables
|
Technical
|
641266
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
5.1
|
Marking - Equipment marking
|
Technical
|
821066
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
2.6.3
|
Switchboards - Mounting height
|
Technical
|
821103
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
3.5.3
|
Event wiring systems - Cables installed on ground, floor or platform
|
Technical
|
211935
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
8.3.2.2
|
TESTING - Test methods - Recording of results
|
Technical
|
631103
|
AS/NZS 4777.2:2020 +A1 Grid connection of energy systems via inverters Inverter requirements
|
5.5.2
|
Testing combinations - Single phase inverters used in three-phase combinations
|
Technical
|
821094
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
3.4.1
|
Event switchboards - Enclosure
|
Technical
|
641228
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.4.5.2.1
|
Wiring systems - Wiring enclosures for the wiring system - General
|
Technical
|
641250
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.6.2
|
Earthing arrangements - Earthing of PV array exposed conductive parts
|
Technical
|
641249
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.6.1
|
Earthing arrangements - General
|
Technical
|
641226
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.4.4.1
|
Wiring systems - Selection of wiring enclosures - Australia only
|
Technical
|
821143
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
3.7.5.2
|
Electrical accessories for events - Electrical portable outlet devices - Connection to low voltage electrical power supp ly
|
Technical
|
641192
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.3.4.2.5
|
Load break disconnectors - Current and voltage rating for circuit breakers
|
Technical
|
641152
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
2.1.6
|
Configuration -Series-parallel configuration
|
Technical
|
641235
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.4.7.2.1
|
Wiring systems - Entries/exits of enclosures containing conductor terminations - General
|
Technical
|
821083
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
2.7.5.4.3
|
Wiring systems - Aerial wiring system - Distance between supports (spans)
|
Technical
|
821098
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
3.4.4
|
Event switchboards - Socket-outlets
|
Technical
|
641084
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
4.3.5.4
|
Disconnecting devices - Circuit breakers used as a disconnecting device
|
Technical
|
631070
|
AS/NZS 4777.2:2020 +A1 Grid connection of energy systems via inverters Inverter requirements
|
3.3.4.3.1
|
Power rate limit modes - General
|
Technical
|
623059
|
AS/NZS 4777.1:2016 Grid connection of energy systems via inverters Installation requirements
|
3.4.4.1
|
Requirements for central protection and inverter integrated protection - General
|
Technical
|
641171
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.2.1.3.3
|
Selection and installation of electrical equipment - Systems containing DCUs on all modules
|
Technical
|
821077
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
2.7.4
|
Wiring systems - Underground wiring
|
Technical
|
631061
|
AS/NZS 4777.2:2020 +A1 Grid connection of energy systems via inverters Inverter requirements
|
3.2.2
|
Inverter demand response modes - Interaction with dmeand response enabling device (DRED)
|
Technical
|
631101
|
AS/NZS 4777.2:2020 +A1 Grid connection of energy systems via inverters Inverter requirements
|
5.4
|
Grid connection and reconnection
|
Technical
|
631091
|
AS/NZS 4777.2:2020 +A1 Grid connection of energy systems via inverters Inverter requirements
|
4.5.4.1
|
Voltage disturbance withstand - General
|
Technical
|
641232
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.4.6.1
|
Wiring systems - Selection of enclosures containing conductor terminations - General
|
Technical
|
631105
|
AS/NZS 4777.2:2020 +A1 Grid connection of energy systems via inverters Inverter requirements
|
5.5.4
|
Testing combinations - Multiple inverters with one automatic disconnection device
|
Technical
|
641095
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
4.4.1.5
|
Disconnecting means - PV disconnector (Australia only)
|
Technical
|
641186
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.3.3.2.3
|
PV module(s) not installed within 1.5m of the PCE
|
Technical
|
641161
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
3.3.4.3
|
Safety issues - Requirements for overcurrent protection - Array
|
Technical
|
641211
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.3.10.3
|
Selection of other PV equipment - d.c conditioning units
|
Technical
|
821104
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
3.5.4
|
Event wiring systems - Underground wiring
|
Technical
|
631072
|
AS/NZS 4777.2:2020 +A1 Grid connection of energy systems via inverters Inverter requirements
|
3.3.4.3.3
|
Power rate limit modes - Changes in a.c. operation and control
|
Technical
|
821092
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
3.2.2.4
|
Event wiring - Supply by generating system - Inverters
|
Technical
|
821088
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
3.2.1.2
|
Event wiring - Supply from electrical installation - Additional protection of event wiring
|
Technical
|
641166
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
3.5.3
|
Safety issues - Protection against earth faults - Earth fault alarm
|
Technical
|
631110
|
AS/NZS 4777.2:2020 +A1 Grid connection of energy systems via inverters Inverter requirements
|
6.3.1
|
Export limit control - General
|
Technical
|
641255
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.6.7.1
|
Earthing arrangements - Direct/resistive functional earthing of arrays - General
|
Technical
|
641229
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.4.5.2.2
|
Wiring systems - Wiring enclosures for the wiring system - Additional mechanical protection requirements
|
Technical
|
641252
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.6.4
|
Earthing arrangements - Connection to installation earthing
|
Technical
|
641070
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
3.3.5.1
|
Overcurrent protection sizing - PV string overcurrent protection
|
Technical
|
631125
|
AS/NZS 4777.2:2020 +A1 Grid connection of energy systems via inverters Inverter requirements
|
7.3.6
|
Documentation - Multiple mode inverters
|
Technical
|
631093
|
AS/NZS 4777.2:2020 +A1 Grid connection of energy systems via inverters Inverter requirements
|
4.5.5
|
Voltage phase angle shift withstand
|
Technical
|
643262
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.7.3.2
|
Verification - Testing - Contiinuity of the earthing system
|
Testing
|
821101
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
3.5.2.2.2
|
Event wiring systems - Keyed single pole Connectors (couplers) - Description of the connection system
|
Technical
|
641200
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.3.6.2
|
Selection of overcurrent protection - Circuit breakers
|
Technical
|
631080
|
AS/NZS 4777.2:2020 +A1 Grid connection of energy systems via inverters Inverter requirements
|
4.1
|
Protective functions for connection to electrical installations and the grid - General
|
Technical
|
641068
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
2.1.4.3
|
Use of PCE with multiple d.c. inputs - PCEs with multiple inputs internally connected together in the PCE
|
Technical
|
821069
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
2.6.6.1
|
Switchboards - Isolation devices - Control
|
Technical
|
641222
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.4.2.5
|
Wiring systems - Selection of cables - Underground cables
|
Technical
|
821089
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
3.2.2.1
|
Event wiring - Supply by generating system - General
|
Technical
|
641260
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.7.2.2
|
Verification - Visual inspection requirements for a PV system - Checklist
|
Technical
|
641074
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
3.4.2.2
|
Systems with direct functional earthing of the PV array - Additional PCE detection required for functionally earthed PV arrays (see Appendix H)
|
Technical
|
631041
|
AS/NZS 4777.2:2020 +A1 Grid connection of energy systems via inverters Inverter requirements
|
2.3.3.1
|
Pluggable type B equipment - General
|
Technical
|
821155
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
3.8.4.1
|
Electrical equipment for events - Prohibited zones around gas cylinders General
|
Technical
|
821096
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
3.4.2
|
Event switchboards - Accessibility
|
Technical
|
641214
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.3.11.2
|
Installation of other PV equipment - Blocking diode
|
Technical
|
641097
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
4.4.2.2
|
Earthing and bonding arrangements - Earth connection of PV array exposed conductive part
|
Technical
|
641243
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.5.2.2
|
Power Conversion equipment - Installation of power conversion equipment - Grid connected inverters
|
Technical
|
821114
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
3.6.1.6
|
Event wiring systems - Flexible cords and cord extension sets - Maximum length
|
Technical
|
213936
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
8.3.7.1
|
TESTING - Polarity and correct circuit connections - General
|
Testing
|
641224
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.4.3.2
|
Wiring systems - Installation of cables - Segregation
|
Technical
|
641181
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.3.2.3.1
|
Selection and installation of electrical equipment - Electrical - General
|
Technical
|
631127
|
AS/NZS 4777.2:2020 +A1 Grid connection of energy systems via inverters Inverter requirements
|
7.3.8
|
Documentation - Firmware
|
Technical
|
821085
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
2.7.6.2
|
Wiring systems - Electrical connections - Enclosure
|
Technical
|
821133
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
3.7.4.3
|
Electrical accessories for events - Outlet boxes - Termination of supply lead
|
Technical
|
821111
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
3.6.1.3
|
Event wiring systems - Flexible cords and cord extension sets - Type of flexible cord and cable
|
Technical
|
641285
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
Appendix I
|
Fire tests, spread of flame and burning brands test
|
Technical
|
631040
|
AS/NZS 4777.2:2020 +A1 Grid connection of energy systems via inverters Inverter requirements
|
2.3.2
|
Permanently connected equipment
|
Technical
|
641072
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
3.3.5.3
|
Overcurrent protection sizing - PV array overcurrent protection
|
Technical
|
631104
|
AS/NZS 4777.2:2020 +A1 Grid connection of energy systems via inverters Inverter requirements
|
5.5.3
|
Testing combinations - required tests for multiple inverter combinations
|
Technical
|
641280
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
6.1
|
System documentation and commissioning - General
|
Technical
|
631075
|
AS/NZS 4777.2:2020 +A1 Grid connection of energy systems via inverters Inverter requirements
|
3.4.1
|
Multiple mode inverter operation - General
|
Technical
|
641101
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
4.4.3.2
|
Functional earthing of PV arrays - Functional earthing terminal of PV system
|
Technical
|
631090
|
AS/NZS 4777.2:2020 +A1 Grid connection of energy systems via inverters Inverter requirements
|
4.5.3.3.2
|
Response to a decrease in frequency - Response to an increase in frequency for multiple mode inverters with energy stora ge
|
Technical
|
631042
|
AS/NZS 4777.2:2020 +A1 Grid connection of energy systems via inverters Inverter requirements
|
2.3.3.2
|
Pluggable type B equipment - Electric vehicle connections
|
Technical
|
641197
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.3.5.3.2
|
load break disconnection device - Load break disconnection devices on systems with string fusing
|
Technical
|
641153
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
2.2.1
|
Other considerations - Considerations due to fault conditions within a PV array
|
Technical
|
821090
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
3.2.2.2
|
Event wiring - Supply by generating system - Residual Current Devices for generator sets and inverters
|
Technical
|
821105
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
3.5.5
|
Event wiring systems - Aerial Wiring
|
Technical
|
821110
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
3.6.1.2
|
Event wiring systems - Flexible cords and cord extension sets - Minimum conductor size and core configuration
|
Technical
|
641103
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
4.4.4.1
|
Wiring system - General
|
Technical
|
641168
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.1
|
Selection and installation of electrical equipment - General
|
Technical
|
821073
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
2.7.3.1
|
Wiring systems - Connection of cables - Direct connections facilities
|
Technical
|
641066
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
2.1.4.1
|
Use of PCE with multiple d.c. inputs - General
|
Technical
|
821062
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
2.5.2
|
Additional proetction by residual current devices (RCDs) - Location of RCD protection
|
Technical
|
641157
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
3.3.1
|
Safety issues - Protection against overcurrent - General
|
Technical
|
631062
|
AS/NZS 4777.2:2020 +A1 Grid connection of energy systems via inverters Inverter requirements
|
3.3.1
|
Inverter power quality response modes - General
|
Technical
|
821071
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
2.7.1
|
Wiring systems - General
|
Technical
|
821097
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
3.4.3
|
Event switchboards - Mounting height
|
Technical
|
631076
|
AS/NZS 4777.2:2020 +A1 Grid connection of energy systems via inverters Inverter requirements
|
3.4.2
|
Multiple mode inverter operation - Sinusoidal output in stand alone mode
|
Technical
|
641287
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
Appendix K
|
Protection against weather and water for dedicated individual enlcosures containing switch disconnectors
|
Technical
|
821100
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
3.5.2.1
|
Event wiring systems - Connection of cables - Direct connections
|
Technical
|
821124
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
3.6.2.7
|
Event wiring systems - Electrical portable outlet devices
|
Technical
|
641233
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.4.6.2
|
Wiring systems - Selection of enclosures containing conductor terminations - Selection of enclosures containing disconne ction device
|
Technical
|
631074
|
AS/NZS 4777.2:2020 +A1 Grid connection of energy systems via inverters Inverter requirements
|
3.3.4.4
|
Power rate limit - Non linearity of power rate limit changes
|
Technical
|
641104
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
4.4.4.2
|
Wiring system - Compliance with wiring Standards
|
Technical
|
641080
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
4.3.3.2
|
PV array and PV equipment - Location of PV array and PV string combiner boxes
|
Technical
|
641180
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.3.2.2.8
|
Selection and installation of electrical equipment - Corrosion
|
Technical
|
821057
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
2.4.2.1
|
General arrangement, control and protection - Connection facility overcurrent protection
|
Technical
|
631043
|
AS/NZS 4777.2:2020 +A1 Grid connection of energy systems via inverters Inverter requirements
|
2.4.1
|
Earth fault/earth leakage detection - Photovoltaic (PV) array earth fault/earth leakage detection
|
Technical
|
211919
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.6.3.2.2
|
Additional protection by residual current devices - Domestic and residential installations
|
Technical
|
211407
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.4.4.1
|
SOCKET-OUTLETS - Switching device - General
|
Technical
|
641190
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.3.4.2.3
|
Load break disconnectors - Current and voltage ratings for switch disconnectors
|
Technical
|
643284
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
6.3.3
|
System documentation and commissioning - Commissioning - Short circuit currents measurement in PV array
|
Testing
|
631086
|
AS/NZS 4777.2:2020 +A1 Grid connection of energy systems via inverters Inverter requirements
|
4.5.3.1
|
Sustained operation for frequency variations - General
|
Technical
|
631057
|
AS/NZS 4777.2:2020 +A1 Grid connection of energy systems via inverters Inverter requirements
|
2.13
|
Measurement accuracy
|
Technical
|
821086
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
3.2
|
Event wiring - Electrical supply
|
Technical
|
641078
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
4.3.2.2
|
PV modules - Operational conditions and external influences
|
Technical
|
213937
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
8.3.7.2
|
TESTING - Polarity and correct circuit connections - Results
|
Testing
|
211924
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.10.2.2.3
|
SWITCHBOARDS - Accessibility and emergency exit facilities - Switchboard doors and switchboard cupboard doors
|
Technical
|
641220
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.4.2.3
|
Wiring systems - Selection of cables - Conductor size
|
Technical
|
211921
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.6.3.2.6
|
Additional protection by residual current devices - Repairs
|
Technical
|
641259
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.7.2.1
|
Verification - Visual inspection requirements for a PV system - General
|
Technical
|
641165
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
3.5.2.2
|
Safety issues - Protection against earth faults - Additional PCE detection required for functionally earthed PV arrays
|
Technical
|
641183
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.3.3.1
|
PV isolation methods for systems exceeding 120V
|
Technical
|
623060
|
AS/NZS 4777.1:2016 Grid connection of energy systems via inverters Installation requirements
|
3.4.4.2
|
Requirements for central protection and inverter integrated protection - Phase balance protection
|
Technical
|
631122
|
AS/NZS 4777.2:2020 +A1 Grid connection of energy systems via inverters Inverter requirements
|
7.3.3
|
Documentation - Ports
|
Technical
|
641096
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
4.4.2.1
|
Earthing and bonding arrangements - General
|
Technical
|
821056
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
2.4.1
|
General arrangement, control and protection - Control and isolation
|
Technical
|
211930
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.9.4
|
PROTECTION AGAINST FIRE HAZARD DUE TO ARCING FAULTS - Arrangement
|
Technical
|
821157
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
3.9
|
Riding devices
|
Technical
|
641077
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
4.3.2.1
|
COMPONENT REQUIREMENTS - PV modules - General
|
Technical
|
821122
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
3.6.2.5
|
Event wiring systems - Auxiliary socket-outlet panels
|
Technical
|
821153
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
3.8.3.4
|
Event Lighting - Loading of lighting systems
|
Technical
|
641251
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.6.3
|
Earthing arrangements - Earthing or bonding connections requirements
|
Technical
|
821068
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
2.6.5
|
Switchboards - Strain relief
|
Technical
|
631114
|
AS/NZS 4777.2:2020 +A1 Grid connection of energy systems via inverters Inverter requirements
|
7.2.1
|
Marking - General
|
Technical
|
641204
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.3.7.1
|
Installation of overcurrent protection - General
|
Technical
|
641209
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.3.10.1
|
Selection of other PV equipment - Bypass diode
|
Technical
|
631119
|
AS/NZS 4777.2:2020 +A1 Grid connection of energy systems via inverters Inverter requirements
|
7.2.6
|
Export limit control - Demand response modes
|
Technical
|
821128
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
3.7.2.4
|
Electrical accessories for events - ACS for event sites - Socket-outlets
|
Technical
|
821108
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
3.5.6.3
|
Event wiring systems - Cables supported by a catenary- Clearances
|
Technical
|
641247
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.5.4.1
|
Power Conversion equipment - Installation of load break disconenction devices - Adjacent and physically separate load br eak disconnection devices
|
Technical
|
821141
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
3.7.4.9
|
Electrical accessories for events - Outlet boxes - Earthing
|
Technical
|
641215
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.3.11.3
|
Installation of other PV equipment - d.c conditioning unit
|
Technical
|
821139
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
3.7.4.7
|
Electrical accessories for events - Outlet boxes - Marking
|
Technical
|
822074
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
2.7.3.1
|
Wiring systems - Connection of cables - Direct connections facilities
|
Unsafe
|
821123
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
3.6.2.6
|
Event wiring systems - Outlet boxes
|
Technical
|
631079
|
AS/NZS 4777.2:2020 +A1 Grid connection of energy systems via inverters Inverter requirements
|
3.5
|
Security of operational settings
|
Technical
|
641217
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.4.1
|
Wiring systems - General
|
Technical
|
821152
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
3.8.3.3.2
|
Event Lighting - Location of lighting - Clearances
|
Technical
|
641082
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
4.3.5.2
|
Disconnecting devices - Switch disconnectors
|
Technical
|
821078
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
2.7.5.1
|
Wiring systems - Aerial wiring system - General
|
Technical
|
641150
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
2.1.2
|
Configuration - PV system architecture
|
Technical
|
641269
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
5.3.1.1
|
Labelling/signs for PV cables and enclosures - Wiring system - General
|
Technical
|
821070
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
2.6.6.2
|
Switchboards - Isolation devices - Marking of isolating switches
|
Technical
|
821081
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
2.7.5.4.1
|
Wiring systems - Aerial wiring system - Clearances - General
|
Technical
|
821109
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
3.6.1.1
|
Event wiring systems - Flexible cords and cord extension sets - Application
|
Technical
|
631085
|
AS/NZS 4777.2:2020 +A1 Grid connection of energy systems via inverters Inverter requirements
|
4.5.2
|
Limits for sustained operation - Sustained operation for voltage variations
|
Technical
|
641256
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.6.7.2
|
Earthing arrangements - Direct/resistive functional earthing of arrays - Functional earthing terminal of PV system
|
Technical
|
643264
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.7.3.4
|
Verification - Testing - Polarity
|
Testing
|
631121
|
AS/NZS 4777.2:2020 +A1 Grid connection of energy systems via inverters Inverter requirements
|
7.3.2
|
Documentation - Equipment ratings
|
Technical
|
641071
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
3.3.5.2.3
|
PV sub-array overcurrent protection - Other arrays
|
Technical
|
631097
|
AS/NZS 4777.2:2020 +A1 Grid connection of energy systems via inverters Inverter requirements
|
4.8
|
Security of protection settings
|
Technical
|
211891
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
8.3.3
|
TESTING - Mandatory tests
|
Technical
|
641278
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
5.7
|
Shutdown procedure
|
Technical
|
821076
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
2.7.3.3
|
Wiring systems - Connection of cables - Socket-outlets for connection facilities
|
Technical
|
631092
|
AS/NZS 4777.2:2020 +A1 Grid connection of energy systems via inverters Inverter requirements
|
4.5.4.2
|
Voltage disturbance withstand - Multiple voltage disturbances
|
Technical
|
211928
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.9.2
|
PROTECTION AGAINST FIRE HAZARD DUE TO ARCING FAULTS - Type
|
Technical
|
631055
|
AS/NZS 4777.2:2020 +A1 Grid connection of energy systems via inverters Inverter requirements
|
2.12.4
|
Isolation of energy sources - PV array ports
|
Technical
|
821151
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
3.8.3.3.1
|
Event Lighting - Location of lighting - Environmental considerations
|
Technical
|
821126
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
3.7.2.2
|
Electrical accessories for events - ACS for event sites - Enclosure
|
Technical
|
641162
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
3.3.5
|
Safety issues - Nominal overcurrent protection rating calculations
|
Technical
|
623068
|
AS/NZS 4777.1:2016 Grid connection of energy systems via inverters Installation requirements
|
5.5.3.3
|
Inverters on the same switchboard - IES connected to switchboards without loads
|
Technical
|
641253
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.6.5
|
Earthing arrangements - Earthing or bonding conductor size
|
Technical
|
631067
|
AS/NZS 4777.2:2020 +A1 Grid connection of energy systems via inverters Inverter requirements
|
3.3.3
|
Fixed power factor mode and reactive power mode
|
Technical
|
631073
|
AS/NZS 4777.2:2020 +A1 Grid connection of energy systems via inverters Inverter requirements
|
3.3.4.3.4
|
Power rate limit modes - Changes in energy source operation
|
Technical
|
821136
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
3.7.4.4.3
|
Electrical accessories for events - Outlet boxes - Overcurrent protection - Operation
|
Technical
|
641242
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.5.2.1
|
Power Conversion equipment - Installation of power conversion equipment - General
|
Technical
|
821087
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
3.2.1.1
|
Event wiring - Supply from electrical installation - Confirmation of overcurrent and RCD protection
|
Technical
|
821137
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
3.7.4.5
|
Electrical accessories for events - Outlet boxes - Protection against earth leakage current
|
Technical
|
641244
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.5.2.3
|
Power Conversion equipment - Installation of power conversion equipment - Power conversion equipment not connected to th e grid
|
Technical
|
631098
|
AS/NZS 4777.2:2020 +A1 Grid connection of energy systems via inverters Inverter requirements
|
4.9
|
Activation of protection settings
|
Technical
|
641155
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
3.1
|
Safety issues - Maximum voltage limits
|
Technical
|
821162
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
4.2.3.2
|
Verification - In Australia - Periodic verification - Event wiring
|
Technical
|
821099
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
3.5.1
|
Event wiring systems - Cable selection
|
Technical
|
641191
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.3.4.2.4
|
Load break disconnectors - Circuit breakers
|
Technical
|
211917
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.6.2.2.1
|
ADDITIONAL PROTECTION BY RESIDUAL CURRENT DEVICES - Types of RCD - General
|
Technical
|
641108
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
4.4.4.6
|
Wiring system - Wiring installation in junction and combiner boxes, and isolator/disconnector boxes
|
Technical
|
631044
|
AS/NZS 4777.2:2020 +A1 Grid connection of energy systems via inverters Inverter requirements
|
2.4.2
|
Earth fault/earth leakage detection - Battery Energy Storage System (BESS) earth fault/earth leakage detection
|
Technical
|
631046
|
AS/NZS 4777.2:2020 +A1 Grid connection of energy systems via inverters Inverter requirements
|
2.6
|
Reactive power capability
|
Technical
|
623067
|
AS/NZS 4777.1:2016 Grid connection of energy systems via inverters Installation requirements
|
5.5.3.2
|
Inverters on the same switchboard - IES connected to switchboards with loads
|
Technical
|
821138
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
3.7.4.6
|
Electrical accessories for events - Outlet boxes - Control switches
|
Technical
|
641087
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
4.3.6.3.1
|
Cables - Installation method - General
|
Technical
|
212938
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
8.3.7.2
|
TESTING - Polarity and correct circuit connections - Results
|
Unsafe
|
641194
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.3.5.2.1
|
Non load break disconnection device - Disconnection point
|
Technical
|
641198
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.3.5.3.3
|
load break disconnection device - Load break disconnection devices on systems without string fusing
|
Technical
|
641195
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.3.5.2.2
|
Non load break disconnection device - Non-load break switch disconnectors and circuit breakers
|
Technical
|
821120
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
3.6.2.3
|
Event wiring systems - detachable connections - Cord extension sockets
|
Technical
|
641206
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.3.7.3
|
Installation of overcurrent protection - Overcurrent protection for PV systems connected to BESS
|
Technical
|
631048
|
AS/NZS 4777.2:2020 +A1 Grid connection of energy systems via inverters Inverter requirements
|
2.8
|
Voltage fluctuations and flicker
|
Technical
|
641207
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.3.8
|
Selection of plugs, sockets and connectors
|
Technical
|
641239
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.5.1.1
|
Power Conversion equipment - Selection of power conversion equipments - General
|
Technical
|
211922
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.10.2.2.1
|
SWITCHBOARDS - Accessibility and emergency exit facilities - Switchboards
|
Technical
|
641099
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
4.4.2.4
|
Earthing and bonding arrangements - PV array protective bonding installation
|
Technical
|
631051
|
AS/NZS 4777.2:2020 +A1 Grid connection of energy systems via inverters Inverter requirements
|
2.11
|
Current balance for three-phase inverters
|
Technical
|
641107
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
4.4.4.5
|
Wiring system - String wiring
|
Technical
|
821067
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
2.6.4
|
Switchboards - Identification
|
Technical
|
641272
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
5.4
|
Fire and emergency information
|
Technical
|
631094
|
AS/NZS 4777.2:2020 +A1 Grid connection of energy systems via inverters Inverter requirements
|
4.5.6
|
Rate of change of frequency
|
Technical
|
631071
|
AS/NZS 4777.2:2020 +A1 Grid connection of energy systems via inverters Inverter requirements
|
3.3.4.3.2
|
Power rate limit modes - Soft ramp up after connect, reconnect or soft ramp up/down following a response to a frequency disturbance
|
Technical
|
641279
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
5.8
|
Labelling of fuse holders
|
Technical
|
623061
|
AS/NZS 4777.1:2016 Grid connection of energy systems via inverters Installation requirements
|
3.4.4.3
|
Requirements for central protection and inverter integrated protection - Central voltage and frequency protection requir ements
|
Technical
|
211932
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
6.2.4.1
|
BATHS, SHOWERS AND OTHER FIXED WATER CONTAINERS - Selection and installation of electrical equipment - Degree of protect ion required
|
Technical
|
631056
|
AS/NZS 4777.2:2020 +A1 Grid connection of energy systems via inverters Inverter requirements
|
2.12.5
|
Isolation of energy sources - Battery system ports
|
Technical
|
631113
|
AS/NZS 4777.2:2020 +A1 Grid connection of energy systems via inverters Inverter requirements
|
7.1
|
Inverter marking and documentation - General
|
Technical
|
211927
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.6.2
|
VOLTAGE DROP - Value
|
Technical
|
641085
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
4.3.6.1
|
Cables - Size
|
Technical
|
821144
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
3.7.5.3
|
Electrical accessories for events - Electrical portable outlet devices - Location
|
Technical
|
821061
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
2.5.1
|
Additional proetction by residual current devices (RCDs) - Requirements for additional RCD protection
|
Technical
|
641175
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.3.2.2.1
|
Selection and installation of electrical equipment - Mechanical - General
|
Technical
|
631065
|
AS/NZS 4777.2:2020 +A1 Grid connection of energy systems via inverters Inverter requirements
|
3.3.2.3
|
Voltage response modes - Volt-var response mode
|
Technical
|
641234
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.4.7.1
|
Wiring systems - Installation of enclosures containing conductor terminations - General
|
Technical
|
821149
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
3.8.3.2.2
|
Event Lighting - Types of Lighting - Rope-light chains
|
Technical
|
641160
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
3.3.4.2
|
Safety issues - Requirements for overcurrent protection - Sub array
|
Technical
|
821119
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
3.6.2.2
|
Event wiring systems - detachable connections - Plugs
|
Technical
|
821054
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
2.2.5
|
Method of supply -Supplementary supply
|
Technical
|
821147
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
3.8.3.1
|
Electrical equipment for events - Event Lighting - General
|
Technical
|
641202
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.3.6.4
|
Selection of overcurrent protection - Fuse holders
|
Technical
|
821142
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
3.7.5.1
|
Electrical accessories for events - Electrical portable outlet devices - General
|
Technical
|
641213
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.3.11.1
|
Installation of other PV equipment - Bypass diode
|
Technical
|
641238
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.4.7.3
|
Wiring systems - Protection against weather and water for dedicated individual enclosures containing switch disconnector s
|
Technical
|
631059
|
AS/NZS 4777.2:2020 +A1 Grid connection of energy systems via inverters Inverter requirements
|
2.15
|
Firmware
|
Technical
|
641102
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
4.4.3.3
|
Functional earthing of PV arrays - PV system functional earthing conductor
|
Technical
|
641093
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
4.4.1.3
|
Disconnecting means - Installation
|
Technical
|
631066
|
AS/NZS 4777.2:2020 +A1 Grid connection of energy systems via inverters Inverter requirements
|
3.3.2.4
|
Voltage response modes - Voltage balance modes
|
Technical
|
821156
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
3.8.4.2
|
Electrical equipment for events - Electrical equipment near gas cylinders
|
Technical
|
641241
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.5.1.3
|
Power Conversion equipment - Power conversion equipment not connected to the grid
|
Technical
|
821132
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
3.7.4.2
|
Electrical accessories for events - Outlet boxes - Construction
|
Technical
|
631106
|
AS/NZS 4777.2:2020 +A1 Grid connection of energy systems via inverters Inverter requirements
|
6.1
|
General control function - General
|
Technical
|
641075
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
3.5.3.2
|
Surge protection devices (SPDs) - Surge protection devices (SPDs) d.c.
|
Technical
|
631112
|
AS/NZS 4777.2:2020 +A1 Grid connection of energy systems via inverters Inverter requirements
|
6.3.3
|
Export limit control - Hard limit
|
Technical
|
821107
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
3.5.6.2
|
Event wiring systems - Cables supported by a catenary - Catenary supports
|
Technical
|
641193
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.3.5
|
Installation of disconnection devices - General
|
Technical
|
641271
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
5.3.2
|
Labelling/signs for PV cables and enclosures - Signs for Junction boxes containing PV d.c cable terminations
|
Technical
|
821134
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
3.7.4.4.1
|
Electrical accessories for events - Outlet boxes - Overcurrent protection - General
|
Technical
|
641270
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
5.3.1.1
|
Labelling/signs for PV cables and enclosures - Wiring system - In a ceiling space or accessible floor space
|
Technical
|
641076
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
3.5.3.3
|
Surge protection devices (SPDs) - Surge protection devices (SPDs) information technology equipment
|
Technical
|
641236
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.4.7.2.2
|
Wiring systems - Entries/exits of enclosures containing conductor terminations - Cable glands in outdoor locations
|
Technical
|
623063
|
AS/NZS 4777.1:2016 Grid connection of energy systems via inverters Installation requirements
|
3.4.8.1
|
CONTROL AND PROTECTION - Export control of an IES - General
|
Technical
|
821160
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
4.2.2
|
Verification - In Australia - Initial verification of event wiring
|
Technical
|
641177
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.3.2.2.5
|
Selection and installation of electrical equipment - Wind
|
Technical
|
631108
|
AS/NZS 4777.2:2020 +A1 Grid connection of energy systems via inverters Inverter requirements
|
6.2.2
|
Generation limit control - soft limit
|
Technical
|
641227
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.4.5.1
|
Wiring systems - Installation of wiring enclosures - General
|
Technical
|
641273
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
5.5.1
|
Labelling/signs for disconnection device - General
|
Technical
|
631111
|
AS/NZS 4777.2:2020 +A1 Grid connection of energy systems via inverters Inverter requirements
|
6.3.2
|
Export limit control - Soft limit
|
Technical
|
641261
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.7.3.1
|
Verification - Testing - General
|
Technical
|
631050
|
AS/NZS 4777.2:2020 +A1 Grid connection of energy systems via inverters Inverter requirements
|
2.1
|
DC Current injection
|
Technical
|
641098
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
4.4.2.3
|
Earthing and bonding arrangements - Protective equipotential bonding
|
Technical
|
641258
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.7.1
|
Verification - General
|
Technical
|
821052
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
2.2.3
|
Method of supply - Alternative supply
|
Technical
|
641179
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.3.2.2.7
|
Selection and installation of electrical equipment -Snow/ice accumulation
|
Technical
|
643263
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.7.3.3
|
Verification - Testing - Insulation resistance
|
Testing
|
641176
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.3.2.2.3
|
Selection and installation of electrical equipment - Mechanical loads on PV structures
|
Technical
|
821158
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
4.1
|
Verification - General
|
Technical
|
631100
|
AS/NZS 4777.2:2020 +A1 Grid connection of energy systems via inverters Inverter requirements
|
5.3
|
Grid disconnection
|
Technical
|
821127
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
3.7.2.3
|
Electrical accessories for events - ACS for event sites - Location
|
Technical
|
821150
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
3.8.3.2.3
|
Event Lighting - Types of Lighting - General lighting
|
Technical
|
641257
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.6.7.3
|
Earthing arrangements - Direct/resistive functional earthing of arrays - PV system functional earthing conductor
|
Technical
|
641267
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
5.2.1
|
Marking - Requirements for labels and signs - General
|
Technical
|
641178
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.3.2.2.6
|
Selection and installation of electrical equipment - Attaching PV modules to the array structure
|
Technical
|
821118
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
3.6.1.8.2
|
Event wiring systems - Flexible cords and cord extension sets - Installed on event fencing
|
Technical
|
641188
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.3.4.2.1
|
Load break disconnectors - General
|
Technical
|
641163
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
3.5.1
|
Safety issues - Protection against earth faults - General
|
Technical
|
821115
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
3.6.1.7
|
Event wiring systems - Flexible cords and cord extension sets - Protection of flexible cords or cables
|
Technical
|
641225
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.4.3.3
|
Wiring systems - Installation of cables - Termination
|
Technical
|
641282
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
6.3.1
|
System documentation and commissioning - Commissioning - General
|
Technical
|
631063
|
AS/NZS 4777.2:2020 +A1 Grid connection of energy systems via inverters Inverter requirements
|
3.3.2.1
|
Voltage response modes - General
|
Technical
|
821117
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
3.6.1.8.1
|
Event wiring systems - Flexible cords and cord extension sets - Installation of flexible cords or cables - Location
|
Technical
|
631078
|
AS/NZS 4777.2:2020 +A1 Grid connection of energy systems via inverters Inverter requirements
|
3.4.4
|
Multiple mode inverter operation - Stand alone inverters
|
Technical
|
641184
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.3.3.2.1
|
PV isolation methods for systems not exceeding 120V - General
|
Technical
|
631045
|
AS/NZS 4777.2:2020 +A1 Grid connection of energy systems via inverters Inverter requirements
|
2.5
|
Compatibility with electrical installation
|
Technical
|
821159
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
4.2.1
|
Verification - In Australia - Initial verification of installation wiring
|
Technical
|
641277
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
5.6.1.1
|
Recording of solar system layout - Additional information for PV d.c. systems
|
Technical
|
641094
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
4.4.1.4
|
Disconnecting means - Requirements for multiple disconnection devices
|
Technical
|
821154
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
3.8.3.5
|
Event Lighting - Protection against earth leakage current
|
Technical
|
623066
|
AS/NZS 4777.1:2016 Grid connection of energy systems via inverters Installation requirements
|
5.5.3.1
|
Inverters on the same switchboard - General
|
Technical
|
821053
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
2.2.4
|
Method of supply - Standalone supply
|
Technical
|
631053
|
AS/NZS 4777.2:2020 +A1 Grid connection of energy systems via inverters Inverter requirements
|
2.12.2
|
Isolation of energy sources - Switch disconnector
|
Technical
|
821146
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
3.8.2
|
Electrical equipment for events - Electrical accessories
|
Technical
|
821079
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
2.7.5.2
|
Wiring systems - Aerial wiring system - Types of conductor
|
Technical
|
641286
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
Appendix J
|
Determination of safety factor (SF) multiplier and Ki for Isc mod for bifacial installations
|
Technical
|
631126
|
AS/NZS 4777.2:2020 +A1 Grid connection of energy systems via inverters Inverter requirements
|
7.3.7
|
Documentation - multiple inverter combinations
|
Technical
|
822064
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
2.6.1
|
Switchboards - General
|
Unsafe
|
631099
|
AS/NZS 4777.2:2020 +A1 Grid connection of energy systems via inverters Inverter requirements
|
5.2
|
Inverter current balance across multiple phases
|
Technical
|
631058
|
AS/NZS 4777.2:2020 +A1 Grid connection of energy systems via inverters Inverter requirements
|
2.14
|
Prioritisation of protection and operational modes
|
Technical
|
641274
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
5.5.2.1
|
Labelling/signs for disconnection device - PV disconnecting device - Load break disconnection device
|
Technical
|
631124
|
AS/NZS 4777.2:2020 +A1 Grid connection of energy systems via inverters Inverter requirements
|
7.3.5
|
Documentation - Residual current devices
|
Technical
|
641169
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.2.1.2
|
Selection and installation of electrical equipment - PV module maximum voltage calculation
|
Technical
|
641187
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.3.4.1
|
Selection of load break disconnection devices - General
|
Technical
|
821060
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
2.4.2.4
|
General arrangement, control and protection - Overcurrent protection marking requirements
|
Technical
|
641210
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.3.10.2
|
Selection of other PV equipment - Blocking diode
|
Technical
|
631081
|
AS/NZS 4777.2:2020 +A1 Grid connection of energy systems via inverters Inverter requirements
|
4.2
|
Automatic disconnection device
|
Technical
|
641221
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.4.2.4
|
Wiring systems - Selection of cables - Voltage drop
|
Technical
|
643265
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.7.3.5
|
Verification - Testing - Open circuit voltage (Voc)
|
Testing
|
641223
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.4.3.1
|
Wiring systems - Installation of cables - General
|
Technical
|
821148
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
3.8.3.2.1
|
Event Lighting - Types of Lighting - Lighting chains
|
Technical
|
211925
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.10.3.2
|
SWITCHBOARDS - Suitability
|
Technical
|
641205
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.3.7.2
|
Installation of overcurrent protection - Overcurrent protection integrated into plugs, sockets and connectors
|
Technical
|
641281
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
6.2
|
System documentation and commissioning - System manual
|
Technical
|
821084
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
2.7.6.1
|
Wiring systems - Electrical connections - General
|
Technical
|
631039
|
AS/NZS 4777.2:2020 +A1 Grid connection of energy systems via inverters Inverter requirements
|
2.3.1
|
Provision for external connections - General
|
Technical
|
821161
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
4.2.3.1
|
Verification - In Australia - Periodic verification - Installation wiring
|
Technical
|
821059
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
2.4.2.3
|
General arrangement, control and protection - Final subcircuit overcurrent protection
|
Technical
|
641201
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.3.6.3
|
Selection of overcurrent protection - Fuses
|
Technical
|
631054
|
AS/NZS 4777.2:2020 +A1 Grid connection of energy systems via inverters Inverter requirements
|
2.12.3
|
Isolation of energy sources - Circuit breaker
|
Technical
|
211933
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.3.4.1
|
ELECTRICITY GENERATION SYSTEMS - Isolation - General
|
Technical
|
641158
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
3.3.2
|
Safety issues - Protection against overcurrent - Potential fault currents not originating at PV modules
|
Technical
|
822095
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
3.4.1
|
Event switchboards - Enclosure
|
Unsafe
|
641100
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
4.4.3.1
|
Functional earthing of PV arrays - General
|
Technical
|
631116
|
AS/NZS 4777.2:2020 +A1 Grid connection of energy systems via inverters Inverter requirements
|
7.2.3
|
Export limit control - Ports
|
Technical
|
631118
|
AS/NZS 4777.2:2020 +A1 Grid connection of energy systems via inverters Inverter requirements
|
7.2.5
|
Export limit control - Residual current devices (RCDs)
|
Technical
|
641245
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.5.3.1
|
Power Conversion equipment - Selection of load break disconnection devices for PCE - General
|
Technical
|
631049
|
AS/NZS 4777.2:2020 +A1 Grid connection of energy systems via inverters Inverter requirements
|
2.9
|
Transient voltage limits
|
Technical
|
641109
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
D4
|
INSULATION RESISTANCE MEASUREMENT
|
Testing
|
821121
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
3.6.2.4
|
Event wiring systems - Assembly for construction sites
|
Technical
|
641167
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
3.6
|
Safety issues - Protection against effects of lighting
|
Technical
|
641156
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
3.2
|
Safety issues - Protection against electric shock
|
Technical
|
211929
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.9.3
|
PROTECTION AGAINST FIRE HAZARD DUE TO ARCING FAULTS - Rating
|
Technical
|
821140
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
3.7.4.8
|
Electrical accessories for events - Outlet boxes - Socket-outlets
|
Technical
|
631047
|
AS/NZS 4777.2:2020 +A1 Grid connection of energy systems via inverters Inverter requirements
|
2.7
|
Harmonic currents
|
Technical
|
821093
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
3.3
|
Event wiring - Maximum demand
|
Technical
|
211926
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.4.3
|
CURRENT-CARRYING CAPACITY - Conductors in parallel
|
Technical
|
641079
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
4.3.3.1
|
PV array and PV equipment - Environmental effects
|
Technical
|
641268
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
5.2.2
|
Marking - Requirements for labels and signs - UV resistance
|
Technical
|
643283
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
6.3.2
|
System documentation and commissioning - Commissioning - Commissioning tests
|
Testing
|
641174
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.3.2.1
|
Selection and installation of electrical equipment - Installation of PV modules - General
|
Technical
|
631077
|
AS/NZS 4777.2:2020 +A1 Grid connection of energy systems via inverters Inverter requirements
|
3.4.3
|
Multiple mode inverter operation - Volt-watt response mode for inverters with energy storage when charging
|
Technical
|
631120
|
AS/NZS 4777.2:2020 +A1 Grid connection of energy systems via inverters Inverter requirements
|
7.3.1
|
Documentation - General
|
Technical
|
641212
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.3.10.4
|
Selection of other PV equipment - Electronic devices in combinations with PV elements
|
Technical
|
821129
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
3.7.3.1
|
Electrical accessories for events - Auxiliary socket-outlet panels - Construction
|
Technical
|
641246
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.5.3.2
|
Power Conversion equipment - Load break disconnection devices integrated into the PCE
|
Technical
|
641073
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
3.4.2.1
|
Systems with direct functional earthing of the PV array - General
|
Technical
|
631038
|
AS/NZS 4777.2:2020 +A1 Grid connection of energy systems via inverters Inverter requirements
|
2.2
|
Electrical Safety
|
Technical
|
641083
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
4.3.5.3
|
Disconnecting devices - Earth fault interrupters
|
Technical
|
211923
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.10.2.2.2
|
SWITCHBOARDS - Accessibility and emergency exit facilities - Switchboard rooms
|
Technical
|
623062
|
AS/NZS 4777.1:2016 Grid connection of energy systems via inverters Installation requirements
|
3.4.4.4
|
Requirements for central protection and inverter integrated protection - Connection and reconnection procedure
|
Technical
|
211930
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.3.1
|
CONNECTION OF ELECTRICAL EQUIPMENT - General
|
Technical
|
821080
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
2.7.5.3
|
Wiring systems - Aerial wiring system - Minimum size
|
Technical
|
641275
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
5.5.2.2
|
Labelling/signs for disconnection device - PV disconnecting device - Disconnection point
|
Technical
|
821051
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
2.2.2
|
Method of supply - Normal supply
|
Technical
|
641219
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.4.2.2
|
Wiring systems - Selection of cables - Current carrying capacity
|
Technical
|
841082
|
AS/NZS 3012:2019 +A1 Electrical installations - Construction and demolition sites
|
3.5.1
|
OTHER ELECTRICAL EQUIPMENT ON SITE -General
|
Technical
|
641173
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.3.1.1
|
Selection and installation of electrical equipment - Selection of PV modules - General
|
Technical
|
641172
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.2.2.1
|
Selection and installation of electrical equipment - PV d.c circuit current calculation - General
|
Technical
|
821050
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
2.2.1
|
Method of supply - General
|
Technical
|
211929
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.1.2
|
Electrical equipment - Selection and installation
|
Technical
|
641105
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
4.4.4.3
|
Wiring system - Segregation of circuits
|
Technical
|
641106
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
4.4.4.4
|
Wiring system - Wiring loops
|
Technical
|
641182
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.3.2.3.2
|
Selection and installation of electrical equipment - Restricted access for PV modules
|
Technical
|
641092
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
4.4.1.2
|
Disconnecting means - Disconnector for power conversion equipment (PCE) maintenance
|
Technical
|
641086
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
4.3.6.2
|
Cables - Type
|
Technical
|
641159
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
3.3.4.1
|
Safety issues - Requirements for overcurrent protection - Strings
|
Technical
|
641154
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
2.2.2
|
Other considerations - Considerations due to operating temperature
|
Technical
|
631102
|
AS/NZS 4777.2:2020 +A1 Grid connection of energy systems via inverters Inverter requirements
|
5.5.1
|
Testing combinations - single phase combinations
|
Technical
|
821116
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
3.6.1.8
|
Event wiring systems - Flexible cords and cord extension sets - Installation of flexible cords or cables
|
Technical
|
623064
|
AS/NZS 4777.1:2016 Grid connection of energy systems via inverters Installation requirements
|
3.4.8.2
|
CONTROL AND PROTECTION - Export control of an IES - Hard limit
|
Technical
|
623065
|
AS/NZS 4777.1:2016 Grid connection of energy systems via inverters Installation requirements
|
3.4.8.3
|
CONTROL AND PROTECTION - Export control of an IES - Soft limit
|
Technical
|
641254
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.6.6
|
Earthing arrangements - PV array earth conductor installation
|
Technical
|
631060
|
AS/NZS 4777.2:2020 +A1 Grid connection of energy systems via inverters Inverter requirements
|
3.2.1
|
Inverter demand response modes - General
|
Technical
|
641237
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.4.7.2.3
|
Wiring systems - Entries/exits of enclosures containing conductor terminations - conduits terminating into enclosures co ntaining disconnection devices
|
Technical
|
821058
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
2.4.2.2
|
General arrangement, control and protection - In Australia
|
Technical
|
641164
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
3.5.2.1
|
Safety issues - Protection against earth faults - General
|
Technical
|
821082
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
2.7.5.4.2
|
Wiring systems - Aerial wiring system - Safety warnings
|
Technical
|
213939
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
8.3.10
|
TESTING - Operation of RCDs
|
Testing
|
821130
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
3.7.3.2
|
Electrical accessories for events - Auxiliary socket-outlet panels - Supply
|
Technical
|
641240
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.5.1.2
|
Power Conversion equipment - Grid connected inverters
|
Technical
|
211918
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.6.2.2.2
|
ADDITIONAL PROTECTION BY RESIDUAL CURRENT DEVICES - Types of RCD - Australia Only
|
Technical
|
821091
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
3.2.2.3
|
Event wiring - Supply by generating system - Generating sets
|
Technical
|
821075
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
2.7.3.2
|
Wiring systems - Connection of cables - Keyed single pole connectors
|
Technical
|
641218
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.4.2.1
|
Wiring systems - Selection of cables - General
|
Technical
|
641230
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.4.5.2.3
|
Wiring systems - Wiring enclosures for the wiring system - Wiring systems between disconnection point and load break dis connection device or an application circuit
|
Technical
|
821113
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
3.6.1.5
|
Event wiring systems - Flexible cords and cord extension sets - Accessories for connection
|
Technical
|
631087
|
AS/NZS 4777.2:2020 +A1 Grid connection of energy systems via inverters Inverter requirements
|
4.5.3.2.1
|
Response to a decrease in frequency - General response to a decrease in frequency
|
Technical
|
631083
|
AS/NZS 4777.2:2020 +A1 Grid connection of energy systems via inverters Inverter requirements
|
4.4
|
Voltage and frequency limits (passive ani-islanding protection)
|
Technical
|
631109
|
AS/NZS 4777.2:2020 +A1 Grid connection of energy systems via inverters Inverter requirements
|
6.2.3
|
Generation limit control - hard limit
|
Technical
|
631082
|
AS/NZS 4777.2:2020 +A1 Grid connection of energy systems via inverters Inverter requirements
|
4.3
|
Active anti-islanding protection
|
Technical
|
821145
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
3.8.1
|
Electrical equipment for events - General
|
Technical
|
821112
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
3.6.1.4
|
Event wiring systems - Flexible cords and cord extension sets - Colour
|
Technical
|
631117
|
AS/NZS 4777.2:2020 +A1 Grid connection of energy systems via inverters Inverter requirements
|
7.2.4
|
Export limit control - External and ancillary equipment
|
Technical
|
641090
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
4.3.8.2
|
Fuses - Fuse holders
|
Technical
|
641216
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.3.11.4
|
Installation of other PV equipment - Electronic devices in combinations with PV elements
|
Technical
|
631107
|
AS/NZS 4777.2:2020 +A1 Grid connection of energy systems via inverters Inverter requirements
|
6.2.1
|
Generation limit control - General
|
Technical
|
641089
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
4.3.8.1
|
Fuses - General
|
Technical
|
631064
|
AS/NZS 4777.2:2020 +A1 Grid connection of energy systems via inverters Inverter requirements
|
3.3.2.2
|
Voltage response modes - Volt-watt response mode
|
Technical
|
641091
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
4.4.1.1
|
Disconnecting means - General
|
Technical
|
631123
|
AS/NZS 4777.2:2020 +A1 Grid connection of energy systems via inverters Inverter requirements
|
7.3.4
|
Documentation - External and ancillary equipment
|
Technical
|
641151
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
2.1.4.3
|
Configuration -PCEs with multiple inputs internally connected in the PCE
|
Technical
|
841082
|
AS/NZS 3012:2019 +A1 Electrical installations - Construction and demolition sites
|
3.5.1
|
VERIFICATION - OTHER ELECTRICAL EQUIPMENT ON SITE - General
|
Technical
|
641189
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.3.4.2.2
|
Load break disconnectors - Switch disconnectors
|
Technical
|
631069
|
AS/NZS 4777.2:2020 +A1 Grid connection of energy systems via inverters Inverter requirements
|
3.3.4.2
|
Power rate limit - Gradient of power rate limit
|
Technical
|
821055
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
2.3
|
Maximum demand
|
Technical
|
641088
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
4.3.6.3.2
|
Cables - Installation method - PV d.c. cables within buildings
|
Technical
|
641248
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.5.4.2
|
Power Conversion equipment - Installation of load break disconenction devices - Requirements for multiple disconnection devices
|
Technical
|
631089
|
AS/NZS 4777.2:2020 +A1 Grid connection of energy systems via inverters Inverter requirements
|
4.5.3.3.1
|
Response to an increase in frequency - General response to an increase in frequency
|
Technical
|
631095
|
AS/NZS 4777.2:2020 +A1 Grid connection of energy systems via inverters Inverter requirements
|
4.6
|
Disconnection on external signal
|
Technical
|
641203
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.3.6.5
|
Selection of overcurrent protection - Overcurrent protection for PV systems connected to a battery energy storage system (BESS)
|
Technical
|
821072
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
2.7.2
|
Wiring systems - Cable selection
|
Technical
|
211931
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.18.4
|
GAS APPLIANCES AND EQUIPMENT - Gas relief vent terminal-Natural gas, LP Gas or Biogas
|
Technical
|
211934
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
8.3.2.1
|
TESTING - Test methods - General
|
Technical
|
631096
|
AS/NZS 4777.2:2020 +A1 Grid connection of energy systems via inverters Inverter requirements
|
4.7
|
Connection and reconnection procedure
|
Technical
|
631115
|
AS/NZS 4777.2:2020 +A1 Grid connection of energy systems via inverters Inverter requirements
|
7.2.2
|
Marking - Equipment ratings
|
Technical
|
821125
|
AS/NZS 3002:2021 Electrical Installations - Shows, carnivals and events
|
3.7.2.1
|
Electrical accessories for events - ACS for event sites - General
|
Technical
|
641185
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.3.3.2.2
|
PV module(s) installed within 1.5m of the inverter
|
Technical
|
641069
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
2.1.9
|
Considerations due to operating temperature
|
Technical
|
641170
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.2.1.3.2
|
Selection and installation of electrical equipment - Systems containing partial DCUs
|
Technical
|
631052
|
AS/NZS 4777.2:2020 +A1 Grid connection of energy systems via inverters Inverter requirements
|
2.12.1
|
Isolation of energy sources - General
|
Technical
|
211411
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.4.5
|
SOCKET-OUTLETS - Polarization and phase sequence
|
Technical
|
631068
|
AS/NZS 4777.2:2020 +A1 Grid connection of energy systems via inverters Inverter requirements
|
3.3.4.1
|
Power rate limit - General
|
Technical
|
641208
|
AS/NZS 5033: 2021 Installation and safety requirements for photovoltaic (PV) arrays.
|
4.3.9.1
|
Installation of plugs, sockets and connectors - General
|
Technical
|
211928
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.8.3.3
|
IDENTIFICATION - Exceptions and special applications - Active and neutral conductors
|
Technical
|
111001
|
Electricity Safety Act 1998
|
41A
|
Responsible person
|
Technical
|
111002
|
Electricity Safety Act 1998
|
43 (1)
|
Safety of electrical installations - installation of electrical equipment
|
Technical
|
112002
|
Electricity Safety Act 1998
|
43 (1)
|
Safety of electrical installations - installation of electrical equipment
|
Unsafe
|
111003
|
Electricity Safety Act 1998
|
43 (1A)
|
Safety of electrical installations - electrical equipment work
|
Technical
|
112003
|
Electricity Safety Act 1998
|
43 (1A)
|
Safety of electrical installations - electrical equipment work
|
Unsafe
|
111004
|
Electricity Safety Act 1998
|
43 (2)
|
Safety of electrical installations - occupier obligations
|
Technical
|
112004
|
Electricity Safety Act 1998
|
43 (2)
|
Safety of electrical installations - occupier obligations
|
Unsafe
|
111005
|
Electricity Safety Act 1998
|
43(4)
|
Safety of electrical installations - carrying out electrical installation work safely
|
Technical
|
112005
|
Electricity Safety Act 1998
|
43(4)
|
Safety of electrical installations - carrying out electrical installation work safely
|
Unsafe
|
111006
|
Electricity Safety Act 1998
|
43A
|
Safety of electrical installations-building work
|
Technical
|
112006
|
Electricity Safety Act 1998
|
43A
|
Safety of electrical installations-building work
|
Unsafe
|
111007
|
Electricity Safety Act 1998
|
44 (1)(a)
|
Compliance and testing of electrical installation work - compliant with ESA & ES(G)R
|
Technical
|
111008
|
Electricity Safety Act 1998
|
44 (1)(b)
|
Compliance and testing of electrical installation work - tested before connection to supply
|
Technical
|
111009
|
Electricity Safety Act 1998
|
44 (3)
|
Compliance and testing of electrical installation work - certificate of compliance obligations
|
Technical
|
111010
|
Electricity Safety Act 1998
|
45(1)
|
Inspection of electrical installation work - inspection prior to energisation
|
Technical
|
111011
|
Electricity Safety Act 1998
|
45(2)
|
Inspection of electrical installation work - certificate of inspection prior to connection
|
Technical
|
111012
|
Electricity Safety Act 1998
|
45A
|
Certificates of Electrical Safety
|
Technical
|
111014
|
Electricity Safety Act 1998
|
45A (6)
|
Certificates of Electrical Safety - distribution time frames
|
Technical
|
111015
|
Electricity Safety Act 1998
|
45A (1)(b)
|
Certificates of Electrical Safety - certificate distribution
|
Technical
|
111016
|
Electricity Safety Act 1998
|
45A (2)
|
Certificates of Electrical Safety - certificate requirements P and NP
|
Technical
|
111017
|
Electricity Safety Act 1998
|
45A(2)
|
Certificates of Electrical Safety - incorrect certificate type
|
Technical
|
111018
|
Electricity Safety Act 1998
|
45A
|
Certificates of Electrical Safety - Certificate of Compliance errors
|
Technical
|
111019
|
Electricity Safety Act 1998
|
63
|
Prohibition notice
|
Technical
|
112020
|
Electricity Safety Act 1998
|
63
|
Prohibition notice
|
Unsafe
|
111021
|
Electricity Safety Act 1998
|
65
|
Recall Notice
|
Technical
|
211056
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.1.2
|
GENERAL ARRANGEMENT, CONTROL AND PROTECTION - Selection and installation
|
Technical
|
211059
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.2.1.1
|
ARRANGEMENT OF ELECTRICAL INSTALLATION - Circuits - General
|
Technical
|
211060
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.2.1.2
|
ARRANGEMENT OF ELECTRICAL INSTALLATION - Origin of submains and final subcircuits
|
Technical
|
211061
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.2.1.3
|
ARRANGEMENT OF ELECTRICAL INSTALLATION - Common neutral
|
Technical
|
211062
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.2.1.4
|
ARRANGEMENT OF ELECTRICAL INSTALLATION - Electric vehicle charging circuits
|
Technical
|
211063
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.2.2
|
ARRANGEMENT OF ELECTRICAL INSTALLATION - Maximum demand
|
Technical
|
211064
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.2.3
|
ARRANGEMENT OF ELECTRICAL INSTALLATION - Selection and installation of conductors
|
Technical
|
211066
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.2.4.1
|
ARRANGEMENT OF ELECTRICAL INSTALLATION - Operating characteristics of equipment - General
|
Technical
|
211067
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.2.4.2
|
ARRANGEMENT OF ELECTRICAL INSTALLATION - Operating characteristics of equipment - Voltage
|
Technical
|
211068
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.2.4.3
|
ARRANGEMENT OF ELECTRICAL INSTALLATION - Operating characteristics of equipment - Current
|
Technical
|
211069
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.2.4.4
|
ARRANGEMENT OF ELECTRICAL INSTALLATION - Operating characteristics of equipment - Frequency
|
Technical
|
211070
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.2.4.5
|
ARRANGEMENT OF ELECTRICAL INSTALLATION - Operating characteristics of equipment - Power
|
Technical
|
211071
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.2.4.6
|
ARRANGEMENT OF ELECTRICAL INSTALLATION - Operating characteristics of equipment - Effects on operator or other equipment
|
Technical
|
211073
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.3.1
|
CONTROL OF ELECTRICAL INSTALLATION - General
|
Technical
|
211075
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.3.2.1.1
|
Common control requirements - General - All systems
|
Technical
|
211076
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.3.2.1.2
|
Common control requirements - Alternating current systems
|
Technical
|
211077
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.3.2.1.3
|
Common control requirements - Direct current systems
|
Technical
|
211080
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.3.2.2.1
|
Devices for isolation - General
|
Technical
|
211081
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.3.2.2.2
|
Devices for isolation - Identification
|
Technical
|
211084
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.3.3.2
|
Main switches - General
|
Technical
|
211085
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.3.3.3
|
Main switches - Number of main switches
|
Technical
|
211086
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.3.3.4
|
Main switches - Location and operation
|
Technical
|
211087
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.3.3.5
|
Main switches - Identification
|
Technical
|
211088
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.3.3.6
|
Main switches - Remote control
|
Technical
|
211090
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.3.4.1
|
Additional isolating switches - Electrical installation in an outbuilding
|
Technical
|
211091
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.3.4.2
|
Additional isolating switches - Submains and final subcircuits greater than 100 A
|
Technical
|
211092
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.3.4.3
|
Additional isolating switches - Alternative supply
|
Technical
|
211093
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.3.4.4
|
Additional isolating switches - Identification
|
Technical
|
211094
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.3.4.5
|
Additional isolating switches - Appliances and accessories
|
Technical
|
211096
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.3.5.1
|
Emergency switching including emergency stopping - General
|
Technical
|
211097
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.3.5.2
|
Emergency switching including emergency stopping - Emergency switching devices
|
Technical
|
211098
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.3.5.3
|
Emergency switching including emergency stopping - Installation
|
Technical
|
211099
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.3.5.4
|
Emergency switching including emergency stopping - Identification
|
Technical
|
211101
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.3.6.1
|
Shutting down for mechanical maintenance - General
|
Technical
|
211102
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.3.6.2
|
Shutting down for mechanical maintenance - Devices for shutting down
|
Technical
|
211103
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.3.6.3
|
Shutting down for mechanical maintenance - Installation
|
Technical
|
211104
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.3.6.4
|
Shutting down for mechanical maintenance - Identification
|
Technical
|
211106
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.3.7.1
|
Functional (control) switching - General
|
Technical
|
211107
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.3.7.2
|
Functional (control) switching - Functional switching devices
|
Technical
|
211108
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.3.7.3
|
Functional (control) switching - Identification
|
Technical
|
211109
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.3.7.4
|
Functional (control) switching - Control circuits
|
Technical
|
211111
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.4.1
|
FAULT PROTECTION - General
|
Technical
|
211112
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.4.2
|
FAULT PROTECTION - Protection by automatic disconnection of supply
|
Technical
|
211113
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.4.3
|
FAULT PROTECTION - Types of devices
|
Technical
|
211114
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.4.4
|
FAULT PROTECTION - Auto-reclose devices
|
Technical
|
211117
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.5.1.1
|
PROTECTION AGAINST OVERCURRENT - General requirements
|
Technical
|
211118
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.5.1.2
|
PROTECTION AGAINST OVERCURRENT - Consumer mains
|
Technical
|
211119
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.5.1.3
|
PROTECTION AGAINST OVERCURRENT - Submains and final subcircuits-General arrangement
|
Technical
|
211120
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.5.1.4
|
PROTECTION AGAINST OVERCURRENT - Omission of protective device for safety reasons
|
Technical
|
211121
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.5.2
|
Devices for protection against both overload and short-circuit currents
|
Technical
|
211123
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.5.3.1
|
Protection against overload current - Coordination between conductors and protective devices
|
Technical
|
211124
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.5.3.2
|
Protection against overload current - Position of overload protective device-General arrangement
|
Technical
|
211125
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.5.3.3
|
Protection against overload current - Alternative position of overload protective device
|
Technical
|
211126
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.5.3.4
|
Protection against overload current - Omission of overload protective device
|
Technical
|
211128
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.5.4.1
|
Protection against short-circuit current - Determination of prospective short-circuit current
|
Technical
|
211129
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.5.4.2
|
Protection against short-circuit current - Characteristics of short-circuit protective devices
|
Technical
|
211130
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.5.4.3
|
Protection against short-circuit current - Position of devices for short-circuit protection
|
Technical
|
211132
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.5.4.4.1
|
Protection against short-circuit current - Alternative position of short-circuit protective device - General
|
Technical
|
211133
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.5.4.4.2
|
Protection against short-circuit current - Alternative position of short-circuit protective device - Condition 1
|
Technical
|
211134
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.5.4.4.3
|
Protection against short-circuit current - Alternative position of short-circuit protective device - Condition 2
|
Technical
|
211135
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.5.4.5
|
Protection against short-circuit current - Omission of devices for short-circuit protection
|
Technical
|
211137
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.5.5.1
|
Protection against switchboard internal arcing fault currents - General
|
Technical
|
211138
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.5.5.2
|
Reduction of the probability of the initiation of a switchboard internal arcing fault
|
Technical
|
211139
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.5.5.3
|
Limitation of the harmful effects of a switchboard internal arcing fault
|
Technical
|
211141
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.5.6.1
|
Coordination of overload and short-circuit protective devices - Protection afforded by one device
|
Technical
|
211142
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.5.6.2
|
Coordination of overload and short-circuit protective devices - Protection afforded by separate devices
|
Technical
|
211144
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.5.7.1
|
Reliability of supply - General
|
Technical
|
211146
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.5.7.2.1
|
Reliability of supply - Coordination of protective devices - General
|
Technical
|
211147
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.5.7.2.2
|
Reliability of supply - Coordination of protective devices - Safety service circuit discrimination (selectivity)
|
Technical
|
211148
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.5.7.2.3
|
Reliability of supply - Coordination of protective devices - General supply circuit discrimination (selectivity)
|
Technical
|
211150
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.6.1
|
ADDITIONAL PROTECTION BY RESIDUAL CURRENT DEVICES - General
|
Technical
|
211152
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.6.2.1
|
ADDITIONAL PROTECTION BY RESIDUAL CURRENT DEVICES - Selection and arrangement of devices - General
|
Technical
|
211157
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.6.2.4
|
ADDITIONAL PROTECTION BY RESIDUAL CURRENT DEVICES - Types of RCD - Arrangement
|
Technical
|
211159
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.6.3.1
|
Additional protection by residual current devices - General
|
Technical
|
211161
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.6.3.2.1
|
Additional protection by residual current devices - Installation requirements - General
|
Technical
|
211164
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.6.3.2.3.1
|
Additional protection by residual current devices - Non-domestic and non-residential installations - Types of installati ons
|
Technical
|
211165
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.6.3.2.3.2
|
Additional protection by residual current devices - Non-domestic and non-residential installations - Location of RCD pro tection
|
Technical
|
211166
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.6.3.2.3.3
|
Additional protection by residual current devices - Non-domestic and non-residential installations - Requirements for ad ditional protection
|
Technical
|
211167
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.6.3.2.4
|
Additional protection by residual current devices - Home care installations
|
Technical
|
211171
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.7.1
|
PROTECTION AGAINST OVERVOLTAGE - General
|
Technical
|
211172
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.7.2
|
PROTECTION AGAINST OVERVOLTAGE - Protection by insulation or separation
|
Technical
|
211173
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.7.3
|
PROTECTION AGAINST OVERVOLTAGE - Protection by protective devices
|
Technical
|
211175
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.8.1
|
PROTECTION AGAINST UNDERVOLTAGE - General
|
Technical
|
211176
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.8.2
|
PROTECTION AGAINST UNDERVOLTAGE - Selection of protective device
|
Technical
|
211178
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.10.1
|
SWITCHBOARDS - General
|
Technical
|
211180
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.10.2.1
|
SWITCHBOARDS - Location of switchboards - General
|
Technical
|
211182
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.10.2.3
|
SWITCHBOARDS - Location of main switchboard
|
Technical
|
211183
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.10.2.4
|
SWITCHBOARDS - Identification of main switchboard
|
Technical
|
211184
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.10.2.5
|
SWITCHBOARDS - Restricted locations
|
Technical
|
212186
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.10.3.1
|
SWITCHBOARDS - Construction - Access to live parts
|
Unsafe
|
211188
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.10.3.3
|
SWITCHBOARDS - Minimum clearances and creepage distances
|
Technical
|
211189
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.10.3.4
|
SWITCHBOARDS - Orientation and location of fuses and circuit-breakers
|
Technical
|
211190
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.10.3.4.1
|
SWITCHBOARDS - Orientation of circuit-breakers
|
Technical
|
211191
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.10.3.4.2
|
SWITCHBOARDS - Location of fuses and circuit-breakers
|
Technical
|
211192
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.10.3.5
|
SWITCHBOARDS - Screw-in fuses
|
Technical
|
211194
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.10.4.1
|
SWITCHBOARDS - Bars - General
|
Technical
|
211195
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.10.4.2
|
SWITCHBOARDS - Tunnel-type terminals
|
Technical
|
211196
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.10.4.3
|
SWITCHBOARDS - Neutral bar
|
Technical
|
211198
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.10.5.1
|
SWITCHBOARDS - Equipment identification - General
|
Technical
|
211199
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.10.5.2
|
SWITCHBOARDS - Relationship of electrical equipment
|
Technical
|
211200
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.10.5.3
|
SWITCHBOARDS - Bars
|
Technical
|
211201
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.10.5.4
|
SWITCHBOARDS - Terminals of switchboard equipment
|
Technical
|
211202
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.10.5.5
|
SWITCHBOARDS - Common neutral
|
Technical
|
211203
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.10.5.6
|
SWITCHBOARDS - Fuse
|
Technical
|
211204
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.10.6
|
SWITCHBOARDS - Wiring
|
Technical
|
211205
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.10.7
|
SWITCHBOARDS - Fire-protective measures
|
Technical
|
211207
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.1.2
|
WIRING SYSTEMS - Selection and installation
|
Technical
|
211208
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.2
|
TYPES OF WIRING SYSTEMS
|
Technical
|
211210
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.3.1
|
EXTERNAL INFLUENCES - General
|
Technical
|
211211
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.3.2
|
EXTERNAL INFLUENCES - Particular influences
|
Technical
|
211212
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.3.2.1
|
EXTERNAL INFLUENCES - Ambient temperature
|
Technical
|
211213
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.3.2.2
|
EXTERNAL INFLUENCES - External heat sources
|
Technical
|
211214
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.3.2.3
|
EXTERNAL INFLUENCES - Water or high humidity
|
Technical
|
211215
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.3.2.4
|
EXTERNAL INFLUENCES - Solid foreign bodies
|
Technical
|
211216
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.3.2.5
|
EXTERNAL INFLUENCES - Corrosive or polluting substances
|
Technical
|
211217
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.3.2.6
|
EXTERNAL INFLUENCES - Mechanical damage
|
Technical
|
211218
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.3.2.7
|
EXTERNAL INFLUENCES - Vibration
|
Technical
|
211219
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.3.2.8
|
EXTERNAL INFLUENCES - Other mechanical stresses
|
Technical
|
211220
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.3.2.9
|
EXTERNAL INFLUENCES - Flora
|
Technical
|
211221
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.3.2.10
|
EXTERNAL INFLUENCES - Fauna
|
Technical
|
211222
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.3.2.11
|
EXTERNAL INFLUENCES - Solar radiation (direct sunlight)
|
Technical
|
211223
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.3.2.12
|
EXTERNAL INFLUENCES - Hazardous areas
|
Technical
|
211224
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.3.2.13
|
EXTERNAL INFLUENCES - Thermal insulation
|
Technical
|
211226
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.4.1
|
CURRENT-CARRYING CAPACITY - General
|
Technical
|
211227
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.4.2
|
CURRENT-CARRYING CAPACITY - Operating temperature limits
|
Technical
|
211229
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.4.4
|
CURRENT-CARRYING CAPACITY - Coordination between conductors and protective devices
|
Technical
|
211231
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.5.1
|
CONDUCTOR SIZE - General
|
Technical
|
211232
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.5.2
|
CONDUCTOR SIZE - Neutral conductor
|
Technical
|
211233
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.5.3
|
CONDUCTOR SIZE - Earthing conductor
|
Technical
|
211235
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.6.1
|
VOLTAGE DROP - General
|
Technical
|
211237
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.6.3
|
VOLTAGE DROP - Conductors in parallel
|
Technical
|
211239
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.7.1
|
ELECTRICAL CONNECTIONS - General
|
Technical
|
211240
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.7.2
|
ELECTRICAL CONNECTIONS - Connection methods
|
Technical
|
211241
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.7.2.1.1
|
ELECTRICAL CONNECTIONS - Common requirements
|
Technical
|
211242
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.7.2.1.2
|
ELECTRICAL CONNECTIONS - Aluminium conductors
|
Technical
|
211243
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.7.2.2
|
ELECTRICAL CONNECTIONS - Preparation for connection
|
Technical
|
211245
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.7.2.3.1
|
ELECTRICAL CONNECTIONS - Loosening of connections - General
|
Technical
|
211246
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.7.2.3.2
|
ELECTRICAL CONNECTIONS - Crimp joints (compression joints)
|
Technical
|
211247
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.7.2.4
|
ELECTRICAL CONNECTIONS - Mechanical connection devices
|
Technical
|
211248
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.7.2.5
|
ELECTRICAL CONNECTIONS - Retention of stranded conductors
|
Technical
|
211249
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.7.2.6
|
ELECTRICAL CONNECTIONS - Mechanical stress
|
Technical
|
211250
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.7.2.7
|
ELECTRICAL CONNECTIONS - Soldered connections
|
Technical
|
211251
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.7.2.8
|
ELECTRICAL CONNECTIONS - Flexible cords
|
Technical
|
211253
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.7.2.9.1
|
ELECTRICAL CONNECTIONS - Aerial conductorsJoints and connections
|
Technical
|
211254
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.7.2.9.2
|
ELECTRICAL CONNECTIONS - Aerial conductorsProhibited joints
|
Technical
|
211255
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.7.2.10
|
ELECTRICAL CONNECTIONS - Underground cables
|
Technical
|
211256
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.7.2.11
|
ELECTRICAL CONNECTIONS - Earthing conductors
|
Technical
|
211257
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.7.3
|
ELECTRICAL CONNECTIONS - Joints in cables
|
Technical
|
211258
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.7.4
|
ELECTRICAL CONNECTIONS - Installation couplers
|
Technical
|
211260
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.8.1
|
IDENTIFICATION - General
|
Technical
|
211262
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.8.2.1
|
IDENTIFICATION - Colour identification by sleeving or other means
|
Technical
|
211263
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.8.2.2
|
IDENTIFICATION - Sleeving of existing earthing and bonding conductors
|
Technical
|
211264
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.8.2.3
|
IDENTIFICATION - Sleeving of existing live conductors
|
Technical
|
211266
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.8.3.1
|
IDENTIFICATION - Exceptions and special applications - General
|
Technical
|
211267
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.8.3.2
|
IDENTIFICATION - Exceptions and special applications - Protective earthing and equipotential conductors
|
Technical
|
211269
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.8.3.4
|
IDENTIFICATION - Exceptions and special applications - Alternative and European cable identification colours
|
Technical
|
211270
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.8.3.5
|
IDENTIFICATION - Exceptions and special applications - Aerial earthing conductors
|
Technical
|
211272
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.9.1
|
INSTALLATION REQUIREMENTS - General
|
Technical
|
211273
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.9.2
|
INSTALLATION REQUIREMENTS - Methods of installation
|
Technical
|
211275
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.9.3.1
|
INSTALLATION REQUIREMENTS - Support and fixing - General
|
Technical
|
211276
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.9.3.2
|
INSTALLATION REQUIREMENTS - Support and fixing - Suspended ceilings
|
Technical
|
211278
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.9.3.3.1
|
INSTALLATION REQUIREMENTS - Wiring systems likely to be disturbed - Location
|
Technical
|
211279
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.9.3.3.2
|
INSTALLATION REQUIREMENTS - Wiring systems likely to be disturbed - Support and protection
|
Technical
|
211281
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.9.4.1
|
INSTALLATION REQUIREMENTS - Protection against mechanical damage - General
|
Technical
|
211282
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.9.4.2
|
INSTALLATION REQUIREMENTS - Protection against mechanical damage - Wiring systems near building surfaces
|
Technical
|
211283
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.9.4.3
|
INSTALLATION REQUIREMENTS - Protection against mechanical damage - Wiring systems under wall lining or roofing material
|
Technical
|
211284
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.9.4.3.1
|
INSTALLATION REQUIREMENTS - Protection against mechanical damage - Prohibited locations
|
Technical
|
211285
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.9.4.3.2
|
INSTALLATION REQUIREMENTS - Protection against mechanical damage - Protection required
|
Technical
|
211286
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.9.4.4
|
INSTALLATION REQUIREMENTS - Protection against mechanical damage - Protection methods
|
Technical
|
211287
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.9.5
|
INSTALLATION REQUIREMENTS - Wiring systems installed vertically
|
Technical
|
211288
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.9.6
|
INSTALLATION REQUIREMENTS - Change of direction
|
Technical
|
211291
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.9.7.1.1
|
INSTALLATION REQUIREMENTS - Consumer mains - Protected
|
Technical
|
211292
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.9.7.1.2
|
INSTALLATION REQUIREMENTS - Consumer mains - Unprotected
|
Technical
|
211293
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.9.7.2
|
INSTALLATION REQUIREMENTS - Insulated and sheathed cables
|
Technical
|
211294
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.9.7.3
|
INSTALLATION REQUIREMENTS - Mineral insulated metal sheathed (MIMS) cable
|
Technical
|
211295
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.9.7.4
|
INSTALLATION REQUIREMENTS - Flexible cords used as installation wiring
|
Technical
|
211296
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.9.7.5
|
INSTALLATION REQUIREMENTS - Low voltage track systems
|
Technical
|
211297
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.9.7.6
|
INSTALLATION REQUIREMENTS - Under-carpet wiring systems
|
Technical
|
211299
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.9.8.1
|
INSTALLATION REQUIREMENTS - Prevention of mutual detrimental effects between services - General
|
Technical
|
211301
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.9.8.2.1
|
INSTALLATION REQUIREMENTS - Different electrical installations - Common enclosure/cable
|
Technical
|
211302
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.9.8.2.2
|
INSTALLATION REQUIREMENTS - Different electrical installations - Segregation
|
Technical
|
211303
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.9.8.3
|
INSTALLATION REQUIREMENTS - Segregation of different voltage levels
|
Technical
|
211304
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.9.8.4
|
INSTALLATION REQUIREMENTS - Proximity to non-electrical services
|
Technical
|
212306
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.9.9.1
|
INSTALLATION REQUIREMENTS - Selection and installation to minimize the spread of fire - General
|
Technical
|
211307
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.9.9.2
|
INSTALLATION REQUIREMENTS - Selection and installation to minimize the spread of fire - Precautions
|
Technical
|
211308
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.9.9.3
|
INSTALLATION REQUIREMENTS - Selection and installation to minimize the spread of fire - Penetration of fire barriers
|
Technical
|
211310
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.9.10.1
|
INSTALLATION REQUIREMENTS - Limitation of circulating and eddy currents - General
|
Technical
|
211311
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.9.10.2
|
INSTALLATION REQUIREMENTS - Limitation of circulating and eddy currents - Cables for a.c. circuits-Electromagnetic effec ts
|
Technical
|
211312
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.9.10.3
|
INSTALLATION REQUIREMENTS - Limitation of circulating and eddy currents - Cables with non-ferrous metal sheathing
|
Technical
|
211313
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.9.11
|
INSTALLATION REQUIREMENTS - Minimization of electromagnetic interference
|
Technical
|
211316
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.10.1.1
|
ENCLOSURE OF CABLES - Insulated, unsheathed cables
|
Technical
|
211317
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.10.1.2
|
ENCLOSURE OF CABLES - Insulated and sheathed cables
|
Technical
|
211319
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.10.2.1
|
ENCLOSURE OF CABLES - Wiring enclosures - Types
|
Technical
|
211320
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.10.2.2
|
ENCLOSURE OF CABLES - Wiring enclosures - Change of wiring enclosures
|
Technical
|
211321
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.10.2.3
|
ENCLOSURE OF CABLES - Wiring enclosures - Entry of water
|
Technical
|
211323
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.10.3.1
|
ENCLOSURE OF CABLES - Installation of wiring enclosures - General
|
Technical
|
211324
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.10.3.2
|
ENCLOSURE OF CABLES - Installation of wiring enclosures - Support
|
Technical
|
211325
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.10.3.3
|
ENCLOSURE OF CABLES - Installation of wiring enclosures - Continuity
|
Technical
|
211326
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.10.3.4
|
ENCLOSURE OF CABLES - Installation of wiring enclosures - Bending
|
Technical
|
211327
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.10.3.5
|
ENCLOSURE OF CABLES - Installation of wiring enclosures - Passage for conductors
|
Technical
|
211328
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.10.3.6
|
ENCLOSURE OF CABLES - Installation of wiring enclosures - Terminations
|
Technical
|
211329
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.10.3.7
|
ENCLOSURE OF CABLES - Installation of wiring enclosures - Installation in direct sunlight
|
Technical
|
211330
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.10.3.8
|
ENCLOSURE OF CABLES - Installation of wiring enclosures - Provision for expansion
|
Technical
|
211331
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.10.3.9
|
ENCLOSURE OF CABLES - Installation of wiring enclosures - Cable trunking
|
Technical
|
211333
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.11.1
|
UNDERGROUND WIRING SYSTEMS - Suitability and protection
|
Technical
|
211334
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.11.2
|
UNDERGROUND WIRING SYSTEMS - Classification of wiring systems
|
Technical
|
211336
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.11.3.1
|
UNDERGROUND WIRING SYSTEMS - Category A underground wiring systems
|
Technical
|
211337
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.11.3.2
|
UNDERGROUND WIRING SYSTEMS - Category B underground wiring systems
|
Technical
|
211338
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.11.3.3
|
UNDERGROUND WIRING SYSTEMS - Category C underground wiring system
|
Technical
|
211340
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.11.4.1
|
UNDERGROUND WIRING SYSTEMS - Installation requirements - General
|
Technical
|
211341
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.11.4.2
|
UNDERGROUND WIRING SYSTEMS - Installation requirements - Unenclosed cables
|
Technical
|
211342
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.11.4.3
|
UNDERGROUND WIRING SYSTEMS - Installation requirements - Category B wiring system mechanical protection
|
Technical
|
211343
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.11.4.4
|
UNDERGROUND WIRING SYSTEMS - Installation requirements - Minimum depth of cover
|
Technical
|
211344
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.11.4.5
|
UNDERGROUND WIRING SYSTEMS - Installation requirements - Identification of underground wiring
|
Technical
|
211345
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.11.4.6
|
UNDERGROUND WIRING SYSTEMS - Installation requirements - Marking and recording of underground cable location
|
Technical
|
211346
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.11.5
|
UNDERGROUND WIRING SYSTEMS - Spacing from other underground services
|
Technical
|
211348
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.12.1
|
AERIAL WIRING SYSTEMS - Types of conductor
|
Technical
|
211350
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.12.2.1
|
AERIAL WIRING SYSTEMS - Arrangements - Insulation of aerial conductors
|
Technical
|
211351
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.12.2.2
|
AERIAL WIRING SYSTEMS - Arrangements - Minimum size
|
Technical
|
211352
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.12.3
|
AERIAL WIRING SYSTEMS - Clearances
|
Technical
|
211353
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.12.3.1
|
AERIAL WIRING SYSTEMS - Clearances - General
|
Technical
|
211354
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.12.3.2
|
AERIAL WIRING SYSTEMS - Clearances - Safety warnings
|
Technical
|
211355
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.12.4
|
AERIAL WIRING SYSTEMS - Distance between supports (spans)
|
Technical
|
211357
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.12.5.1
|
AERIAL WIRING SYSTEMS - Aerial conductor supports - General
|
Technical
|
211358
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.12.5.2
|
AERIAL WIRING SYSTEMS - Aerial conductor supports - Pin-type insulators
|
Technical
|
211359
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.12.5.3
|
AERIAL WIRING SYSTEMS - Aerial conductor supports - Hardware
|
Technical
|
211360
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.12.5.4
|
AERIAL WIRING SYSTEMS - Aerial conductor supports - Spacing between conductors
|
Technical
|
211361
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.12.6
|
AERIAL WIRING SYSTEMS - Poles and posts (including supports, struts and extensions to structures)
|
Technical
|
211362
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.12.7
|
AERIAL WIRING SYSTEMS - Joints and connections
|
Technical
|
211364
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.13.1
|
CABLES SUPPORTED BY A CATENARY - Types of cables
|
Technical
|
211365
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.13.2
|
CABLES SUPPORTED BY A CATENARY - Catenary supports
|
Technical
|
211366
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.13.3
|
CABLES SUPPORTED BY A CATENARY - Clearances
|
Technical
|
211367
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.14
|
SAFETY SERVICES
|
Technical
|
211368
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.15
|
BUSWAYS, INCLUDING RISING MAINS SYSTEMS
|
Technical
|
211369
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
3.16
|
EARTH SHEATH RETURN (ESR) SYSTEM
|
Technical
|
211372
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.1.3
|
Electrical equipment - External influences
|
Technical
|
211373
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.1.4
|
Electrical equipment - Adverse effects and interference
|
Technical
|
211375
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.2.1
|
PROTECTION AGAINST THERMAL EFFECTS - General
|
Technical
|
211377
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.2.2.1
|
PROTECTION AGAINST THERMAL EFFECTS - Prevention of fire hazard - Installation of electrical equipment
|
Technical
|
211378
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.2.2.2
|
PROTECTION AGAINST THERMAL EFFECTS - Prevention of fire hazard - Storage of flammable materials
|
Technical
|
211379
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.2.2.3
|
PROTECTION AGAINST THERMAL EFFECTS - Prevention of fire hazard - Protection from high temperatures
|
Technical
|
211380
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.2.2.4
|
PROTECTION AGAINST THERMAL EFFECTS - Prevention of fire hazard - Emission of arcs or sparks
|
Technical
|
211381
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.2.2.5
|
PROTECTION AGAINST THERMAL EFFECTS - Prevention of fire hazard - Electrical equipment enclosures
|
Technical
|
211382
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.2.2.6
|
PROTECTION AGAINST THERMAL EFFECTS - Prevention of fire hazard - Prevention of spread of fire
|
Technical
|
211383
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.2.3
|
PROTECTION AGAINST THERMAL EFFECTS - Protection against burns
|
Technical
|
211387
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.3.2.1
|
CONNECTION OF ELECTRICAL EQUIPMENT - Direct connection - General
|
Technical
|
211388
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.3.2.2
|
CONNECTION OF ELECTRICAL EQUIPMENT - Installation coupler
|
Technical
|
211390
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.3.3.1
|
CONNECTION OF ELECTRICAL EQUIPMENT - Installation wiring connected by an installation coupler(s) - General
|
Technical
|
211391
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.3.3.2
|
CONNECTION OF ELECTRICAL EQUIPMENT - Socket-outlets
|
Technical
|
211392
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.3.4
|
CONNECTION OF ELECTRICAL EQUIPMENT - Socket-outlets in installation wiring
|
Technical
|
211393
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.3.5
|
CONNECTION OF ELECTRICAL EQUIPMENT - Other connecting devices
|
Technical
|
211394
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.3.6
|
CONNECTION OF ELECTRICAL EQUIPMENT - Equipment wiring
|
Technical
|
211397
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.4.1.1.1
|
SOCKET-OUTLETS - Application
|
Technical
|
211398
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.4.1.1.2
|
SOCKET-OUTLETS - Alternative pin configurations
|
Technical
|
211399
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.4.1.1.3
|
SOCKET-OUTLETS - Low voltage fixed socket-outlet
|
Technical
|
211400
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.4.1.2
|
SOCKET-OUTLETS - Different systems
|
Technical
|
211401
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.4.1.3
|
SOCKET-OUTLETS - Socket-outlets for electric vehicle charging
|
Technical
|
211403
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.4.2.1
|
SOCKET-OUTLETS - Location - Accessibility
|
Technical
|
211404
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.4.2.2
|
SOCKET-OUTLETS - Protection of socket-outlets
|
Technical
|
211405
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.4.3
|
SOCKET-OUTLETS - Earthing contacts
|
Technical
|
211408
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.4.4.2
|
SOCKET-OUTLETS - Switching device - Rating
|
Technical
|
211409
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.4.4.3
|
SOCKET-OUTLETS - Switching device - Location and marking
|
Technical
|
211410
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.4.4.4
|
SOCKET-OUTLETS - Switching device - Pendant-type socket-outlet
|
Technical
|
211414
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.5.1.1
|
LIGHTING EQUIPMENT AND ACCESSORIES - Lampholders, including lampholders incorporated in a luminaire - Location
|
Technical
|
211415
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.5.1.2
|
LIGHTING EQUIPMENT AND ACCESSORIES - Edison screw lampholders
|
Technical
|
211416
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.5.1.3
|
LIGHTING EQUIPMENT AND ACCESSORIES - Festoon lighting
|
Technical
|
211418
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.5.2.1
|
LIGHTING EQUIPMENT AND ACCESSORIES - Lamps and luminaires - General
|
Technical
|
211419
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.5.2.2
|
LIGHTING EQUIPMENT AND ACCESSORIES - Lamps near flammable materials
|
Technical
|
211421
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.5.2.3.1
|
Recessed luminaires - General requirements
|
Technical
|
211422
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.5.2.3.2
|
Recessed luminaires - Warning sign
|
Technical
|
211423
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.5.2.3.3
|
Recessed luminaires - Installation
|
Technical
|
211424
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.5.2.3.4
|
Recessed luminaires - Classifications of recessed luminaires
|
Technical
|
211425
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.5.2.3.5
|
Recessed luminaires - Requirements for specific classifications
|
Technical
|
211426
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.5.2.4
|
LIGHTING EQUIPMENT AND ACCESSORIES - Suspended ceilings
|
Technical
|
211427
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.6
|
SMOKE ALARMS
|
Technical
|
211429
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.7.1
|
COOKING APPLIANCES - Switching device
|
Technical
|
211430
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.7.3
|
COOKING APPLIANCES - Clearance from open cooking surfaces
|
Technical
|
211432
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.8.1
|
APPLIANCES PRODUCING HOT WATER OR STEAM - General
|
Technical
|
211434
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.8.2.1
|
WATER HEATERS - Access to easing equipment of pressure-relief and terminals of protective devices
|
Technical
|
211435
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.8.2.2
|
WATER HEATERS - Protective devices fitted to unvented water heaters
|
Technical
|
211436
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.8.2.3
|
WATER HEATERS - Isolating switch
|
Technical
|
211438
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.9.1
|
ROOM HEATERS - General
|
Technical
|
211439
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.9.2
|
ROOM HEATERS - Isolating switches
|
Technical
|
211440
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.9.3
|
ROOM HEATERS - Functional switches
|
Technical
|
211442
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.10.1
|
ELECTRIC HEATING CABLES FOR FLOORS AND CEILINGS AND TRACE HEATING APPLICATIONS - General
|
Technical
|
211443
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.10.2
|
ELECTRIC HEATING CABLES - Heating cables
|
Technical
|
211444
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.10.3
|
ELECTRIC HEATING CABLES - Isolating switches
|
Technical
|
211445
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.10.4
|
ELECTRIC HEATING CABLES - Functional switches
|
Technical
|
211446
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.10.5
|
ELECTRIC HEATING CABLES - Additional protection
|
Technical
|
211447
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.10.6
|
ELECTRIC HEATING CABLES - Signs
|
Technical
|
211448
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.11
|
ELECTRIC DUCT HEATERS
|
Technical
|
211450
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.12.1
|
ELECTRICITY CONVERTERS - General
|
Technical
|
211451
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.12.2
|
ELECTRICITY CONVERTERS - Selection and installation
|
Technical
|
211452
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.12.3
|
ELECTRICITY CONVERTERS - Control
|
Technical
|
211454
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.12.4.1
|
ELECTRICITY CONVERTERS - Isolation - General
|
Technical
|
211455
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.12.4.2
|
ELECTRICITY CONVERTERS - Isolation - Electricity converters incorporating batteries
|
Technical
|
211457
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.12.5.1
|
ELECTRICITY CONVERTERS - Overcurrent protection - Electricity converter protection
|
Technical
|
211459
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.12.5.2.1
|
ELECTRICITY CONVERTERS - Overcurrent protection - Circuit protection - General
|
Technical
|
211460
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.12.5.2.2
|
ELECTRICITY CONVERTERS - Overcurrent protection - Circuit protection - RCDs
|
Technical
|
211461
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.12.6
|
ELECTRICITY CONVERTERS - Earthing
|
Technical
|
211462
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.12.7
|
ELECTRICITY CONVERTERS - Neutral continuity
|
Technical
|
211463
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.12.8
|
ELECTRICITY CONVERTERS - Electrical equipment connected to output
|
Technical
|
211466
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.13.1.1
|
MOTORS - Protection against injury from mechanical movement - Switching devices
|
Technical
|
211467
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.13.1.2
|
MOTORS - Protection against injury from mechanical movement -Rating of switches
|
Technical
|
211468
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.13.1.3
|
MOTORS - Protection against injury from mechanical movement -Devices for starting and stopping
|
Technical
|
211469
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.13.1.4
|
MOTORS - Protection against injury from mechanical movement -Protection against restarting or reversal
|
Technical
|
211470
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.13.2
|
MOTORS - Protection against overload
|
Technical
|
211472
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.13.3.1
|
MOTORS - Protection against overtemperature - General
|
Technical
|
211473
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.13.3.2
|
MOTORS - Protection against overtemperature - Protection prohibited
|
Technical
|
211474
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.13.3.3
|
MOTORS - Protection against overtemperature - Overtemperature protective device
|
Technical
|
211476
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.14.1
|
TRANSFORMERS - General
|
Technical
|
211478
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.14.2.1
|
TRANSFORMERS - Secondary circuit - General
|
Technical
|
211479
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.14.2.2
|
TRANSFORMERS - Secondary circuit - Control and protection
|
Technical
|
211481
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.14.3.1
|
TRANSFORMERS - Low voltage transformer supply - Isolating transformers
|
Technical
|
211482
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.14.3.2
|
TRANSFORMERS - Low voltage transformer supply - Other transformers
|
Technical
|
211483
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.14.4
|
TRANSFORMERS - Autotransformers
|
Technical
|
211484
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.14.5
|
TRANSFORMERS - Step-up transformers
|
Technical
|
211486
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.15.1
|
CAPACITORS - General
|
Technical
|
211488
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.15.2.1
|
CAPACITORS - Electrical equipment - General
|
Technical
|
211489
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.15.2.2
|
CAPACITORS - Electrical equipment - Rating of circuit-breakers, switches or contactors
|
Technical
|
211490
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.15.2.3
|
CAPACITORS - Electrical equipment - Current-carrying capacity of supply conductors
|
Technical
|
211492
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.15.3.1
|
CAPACITORS - Provision for discharge and control - General
|
Technical
|
211493
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.15.3.2
|
CAPACITORS - Capacitors connected in parallel with individual appliances
|
Technical
|
211494
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.15.3.3
|
CAPACITORS - Capacitors not connected in parallel with individual appliances
|
Technical
|
211496
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.16.1
|
ELECTRICAL EQUIPMENT CONTAINING LIQUID DIELECTRICS - General
|
Technical
|
211497
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.16.2
|
ELECTRICAL EQUIPMENT CONTAINING LIQUID DIELECTRICS - Liquid dielectrics having a flashpoint not exceeding 250 degC
|
Technical
|
211501
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.18.1.1
|
GAS APPLIANCES AND EQUIPMENT - General
|
Technical
|
211502
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.18.1.2
|
GAS APPLIANCES AND EQUIPMENT - Gas appliances - In Australia only
|
Technical
|
211505
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.18.2.1
|
GAS APPLIANCES AND EQUIPMENT - Gas cylinders containing heavier-than-air gases-Outdoors - Sources of ignition
|
Technical
|
211506
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.18.2.2
|
GAS APPLIANCES AND EQUIPMENT - Gas cylinders containing heavier-than-air gases-Outdoors - Hot particles and surfaces
|
Technical
|
211508
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.19
|
AIRCONDITIONING AND HEAT PUMP SYSTEMS
|
Technical
|
211510
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.20.1
|
LIFTS - General
|
Technical
|
211511
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.20.2
|
LIFTS - Lift supply arrangement
|
Technical
|
211512
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.20.3
|
LIFTS - Labelling
|
Technical
|
211514
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.20.4.1
|
LIFTS - Motor-room-less lifts (MRLs) - General
|
Technical
|
211515
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.20.4.2
|
LIFTS - MRL switchboards
|
Technical
|
211516
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.20.4.3
|
LIFTS - Switchgear
|
Technical
|
211518
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
5.1.2
|
EARTHING ARRANGEMENTS AND EARTHING CONDUCTORS - Selection and installation
|
Technical
|
211519
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
5.1.3
|
EARTHING ARRANGEMENTS AND EARTHING CONDUCTORS - MEN earthing system
|
Technical
|
211520
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
5.1.4
|
EARTHING ARRANGEMENTS AND EARTHING CONDUCTORS - Other earthing systems
|
Technical
|
211522
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
5.2.1
|
EARTHING FUNCTIONS - Protective earthing
|
Technical
|
211523
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
5.2.2
|
EARTHING FUNCTIONS - Functional earthing (FE)
|
Technical
|
211524
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
5.2.3
|
EARTHING FUNCTIONS - Earthing for combined protective and functional purposes
|
Technical
|
211526
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
5.3.1
|
EARTHING SYSTEM PARTS - General
|
Technical
|
211529
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
5.3.2.1.1
|
EARTHING SYSTEM PARTS - Conductor material - Copper conductors
|
Technical
|
211530
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
5.3.2.1.2
|
EARTHING SYSTEM PARTS - Conductor material - Aluminium conductors
|
Technical
|
211531
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
5.3.2.1.3
|
EARTHING SYSTEM PARTS - Conductor material - Other materials
|
Technical
|
211532
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
5.3.2.2
|
EARTHING SYSTEM PARTS - Conductor type
|
Technical
|
211533
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
5.3.2.3
|
EARTHING SYSTEM PARTS - Special conditions
|
Technical
|
211534
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
5.3.2.4
|
EARTHING SYSTEM PARTS - Insulation
|
Technical
|
211535
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
5.3.2.5
|
EARTHING SYSTEM PARTS - Identification
|
Technical
|
211538
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
5.3.3.1.1
|
Earthing conductor size - Protective earthing conductors - General
|
Technical
|
211539
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
5.3.3.1.2
|
Earthing conductor size - Protective earthing conductors - Selection
|
Technical
|
211540
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
5.3.3.1.3
|
Earthing conductor size - Protective earthing conductors - Calculation
|
Technical
|
211541
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
5.3.3.2
|
Earthing conductor size - Main earthing conductor
|
Technical
|
211542
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
5.3.3.3
|
Earthing conductor size - Aerial earthing conductors
|
Technical
|
211543
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
5.3.3.4
|
Earthing conductor size - Earthing conductors in cables, flexible cables or flexible cords
|
Technical
|
211544
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
5.3.4
|
Main earthing terminal/connection or bar
|
Technical
|
211546
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
5.3.5.1
|
MEN connection - General
|
Technical
|
211547
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
5.3.5.2
|
MEN connection - Size
|
Technical
|
211548
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
5.3.5.3
|
MEN connection - Identification
|
Technical
|
211550
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
5.3.6.1
|
Earth electrodes - General
|
Technical
|
211551
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
5.3.6.2
|
Earth electrodes - Types
|
Technical
|
211552
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
5.3.6.3
|
Earth electrodes - Installation
|
Technical
|
211553
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
5.3.6.4
|
Earth electrodes - Location
|
Technical
|
211554
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
5.3.7
|
Functional earthing conductors
|
Technical
|
211558
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
5.4.1.2
|
EARTHING OF EQUIPMENT - Conductive building materials
|
Technical
|
211559
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
5.4.1.3
|
EARTHING OF EQUIPMENT - Connection of electrical equipment to earth
|
Technical
|
211560
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
5.4.2
|
EARTHING OF EQUIPMENT - Socket-outlets
|
Technical
|
211561
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
5.4.3
|
EARTHING OF EQUIPMENT - Lighting points
|
Technical
|
211562
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
5.4.4
|
EARTHING OF EQUIPMENT - Luminaires
|
Technical
|
211563
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
5.4.5
|
EARTHING OF EQUIPMENT - Conductive supports for aerial conductors
|
Technical
|
212565
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
5.4.6.1
|
EARTHING OF EQUIPMENT - Structural metalwork including conductive building materials - General
|
Unsafe
|
213566
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
5.4.6.2
|
EARTHING OF EQUIPMENT - Connection to protective earthing conductors
|
Testing
|
211567
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
5.4.7
|
EARTHING OF EQUIPMENT - Submersible pumps
|
Technical
|
211571
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
5.5.1.1
|
EARTHING ARRANGEMENTS - Main earthing conductor - Arrangement
|
Technical
|
211572
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
5.5.1.2
|
EARTHING ARRANGEMENTS - Main earthing conductor - Connection to earth electrode
|
Technical
|
211573
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
5.5.1.3
|
EARTHING ARRANGEMENTS - Main earthing conductor - Labelling
|
Technical
|
211574
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
5.5.1.4
|
EARTHING ARRANGEMENTS - Main earthing conductor - Resistance
|
Technical
|
211576
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
5.5.2.1
|
EARTHING ARRANGEMENTS - Protective earthing conductors - Arrangement
|
Technical
|
211578
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
5.5.2.2.1
|
EARTHING ARRANGEMENTS - Protective earthing conductors - Restricted connections - Circuits
|
Technical
|
211579
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
5.5.2.2.2
|
EARTHING ARRANGEMENTS - Protective earthing conductors - Restricted connections - Earthing of equipment
|
Technical
|
211580
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
5.5.2.2.3
|
EARTHING ARRANGEMENTS - Protective earthing conductors - Restricted connections - Earthing facilities for distribution b oards
|
Technical
|
211582
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
5.5.3.1
|
EARTHING ARRANGEMENTS - Particular methods of earthing - Outbuildings
|
Technical
|
211583
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
5.5.3.2
|
EARTHING ARRANGEMENTS - Particular methods of earthing - Wiring systems
|
Technical
|
211584
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
5.5.3.3
|
EARTHING ARRANGEMENTS - Particular methods of earthing - Electrical equipment supplied by flexible cord or flexible cabl e
|
Technical
|
211585
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
5.5.3.4
|
EARTHING ARRANGEMENTS - Particular methods of earthing - Switchboards
|
Technical
|
211586
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
5.5.3.5
|
EARTHING ARRANGEMENTS - Particular methods of earthing - Unprotected consumer mains
|
Technical
|
211588
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
5.5.4.1
|
EARTHING ARRANGEMENTS - Continuity - General
|
Technical
|
211589
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
5.5.4.2
|
EARTHING ARRANGEMENTS - Continuity - Conductive wiring enclosures
|
Technical
|
211590
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
5.5.4.3
|
EARTHING ARRANGEMENTS - Continuity - Conductive sheaths, armours and screens of cables
|
Technical
|
211591
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
5.5.4.4
|
EARTHING ARRANGEMENTS - Continuity - Connecting devices
|
Technical
|
211593
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
5.5.5.1
|
EARTHING ARRANGEMENTS - Installation - General
|
Technical
|
211594
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
5.5.5.2
|
EARTHING ARRANGEMENTS - Installation - Protection against mechanical damage
|
Technical
|
211595
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
5.5.5.3
|
EARTHING ARRANGEMENTS - Installation - Protection against corrosion
|
Technical
|
211596
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
5.5.5.4
|
EARTHING ARRANGEMENTS - Installation - Aerial earthing conductors
|
Technical
|
211597
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
5.5.5.5
|
EARTHING ARRANGEMENTS - Installation - Buried earthing conductors
|
Technical
|
211599
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
5.5.6.1
|
EARTHING ARRANGEMENTS - Connections - Conductors
|
Technical
|
211600
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
5.5.6.2
|
EARTHING ARRANGEMENTS - Connections - Constructional components
|
Technical
|
211602
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
5.6.1
|
EQUIPOTENTIAL BONDING - General
|
Technical
|
211604
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
5.6.2.1
|
EQUIPOTENTIAL BONDING - Arrangement - General
|
Technical
|
211605
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
5.6.2.2
|
EQUIPOTENTIAL BONDING - Arrangement - Conductive water piping
|
Technical
|
211606
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
5.6.2.3
|
EQUIPOTENTIAL BONDING - Arrangement - Other conductive piping systems
|
Technical
|
211607
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
5.6.2.4
|
EQUIPOTENTIAL BONDING - Arrangement - Conductive cable sheaths and conductive wiring enclosures
|
Technical
|
211608
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
5.6.2.5
|
EQUIPOTENTIAL BONDING - Arrangement - Showers and bathrooms
|
Technical
|
211610
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
5.6.2.6.1
|
EQUIPOTENTIAL BONDING - Swimming and spa pools - Bonding arrangement
|
Technical
|
211611
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
5.6.2.6.2
|
EQUIPOTENTIAL BONDING - Swimming and spa pools - Conductive pool structures
|
Technical
|
211612
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
5.6.2.6.3
|
EQUIPOTENTIAL BONDING - Swimming and spa pools - Pool equipotential bonding conductor connection point
|
Technical
|
211613
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
5.6.2.6.4
|
EQUIPOTENTIAL BONDING - Swimming and spa pools - Electrical equipment
|
Technical
|
211614
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
5.6.2.6.5
|
EQUIPOTENTIAL BONDING - Swimming and spa pools - Conductive fixtures and fittings
|
Technical
|
211615
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
5.6.2.7
|
EQUIPOTENTIAL BONDING - Telephone and telecommunication earthing systems
|
Technical
|
211617
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
5.6.3.1
|
EQUIPOTENTIAL BONDING - Bonding conductors - General
|
Technical
|
211618
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
5.6.3.2
|
EQUIPOTENTIAL BONDING - Bonding conductors - Size
|
Technical
|
211620
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
5.7.1
|
EARTH FAULT-LOOP IMPEDANCE - General
|
Technical
|
211621
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
5.7.2
|
EARTH FAULT-LOOP IMPEDANCE - Disconnection times
|
Technical
|
211622
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
5.7.3
|
EARTH FAULT-LOOP IMPEDANCE - Earth fault-loop
|
Technical
|
211623
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
5.7.4
|
EARTH FAULT-LOOP IMPEDANCE - Impedance
|
Technical
|
211624
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
5.7.5
|
EARTH FAULT-LOOP IMPEDANCE - Supplementary equipotential bonding
|
Technical
|
211625
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
5.8
|
OTHER EARTHING ARRANGEMENTS
|
Technical
|
211627
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
6.1.2
|
DAMP SITUATIONS - Selection and installation
|
Technical
|
211630
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
6.2.2.1
|
BATHS, SHOWERS AND OTHER FIXED WATER CONTAINERS - Classification of zones - Baths and showers
|
Technical
|
211631
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
6.2.2.2
|
BATHS, SHOWERS AND OTHER FIXED WATER CONTAINERS - Classification of zones - Other fixed water containers
|
Technical
|
212632
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
6.2.3
|
BATHS, SHOWERS AND OTHER FIXED WATER CONTAINERS - Protection against electric shock - Prohibited measures
|
Unsafe
|
211635
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
6.2.4.2
|
BATHS, SHOWERS AND OTHER FIXED WATER CONTAINERS - Selection and installation of electrical equipment - Socket-outlets
|
Technical
|
211636
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
6.2.4.3
|
BATHS, SHOWERS AND OTHER FIXED WATER CONTAINERS - Selection and installation of electrical equipment - Switches and othe r accessories
|
Technical
|
211637
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
6.2.4.4
|
BATHS, SHOWERS AND OTHER FIXED WATER CONTAINERS - Selection and installation of electrical equipment - Luminaires
|
Technical
|
211638
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
6.2.4.5
|
BATHS, SHOWERS AND OTHER FIXED WATER CONTAINERS - Selection and installation of electrical equipment - Other electrical equipment
|
Technical
|
211639
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
6.2.4.6
|
BATHS, SHOWERS AND OTHER FIXED WATER CONTAINERS - Selection and installation of electrical equipment - Switchboards
|
Technical
|
211640
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
6.2.4.7
|
BATHS, SHOWERS AND OTHER FIXED WATER CONTAINERS - Selection and installation of electrical equipment - Electricity gener ation systems
|
Technical
|
211643
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
6.3.2.1
|
SWIMMING POOLS, PADDLING POOLS AND SPA POOLS OR TUBS - Classification of zones - Swimming pools and paddling pools
|
Technical
|
211645
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
6.3.2.2.1
|
SWIMMING POOLS, PADDLING POOLS AND SPA POOLS OR TUBS - Classification of zones - Spa pools or tubs - General
|
Technical
|
211646
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
6.3.2.2.2
|
SWIMMING POOLS, PADDLING POOLS AND SPA POOLS OR TUBS - Classification of zones - Spa pools or tubs - Water capacity exce eding 5000 L
|
Technical
|
211647
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
6.3.2.2.3
|
SWIMMING POOLS, PADDLING POOLS AND SPA POOLS OR TUBS - Classification of zones - Spa pools or tubs - Water capacity not exceeding 5000 L
|
Technical
|
211649
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
6.3.3.1
|
SWIMMING POOLS, PADDLING POOLS AND SPA POOLS OR TUBS - Protection against electric shock - Prohibited measures
|
Technical
|
211650
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
6.3.3.2
|
SWIMMING POOLS, PADDLING POOLS AND SPA POOLS OR TUBS - Protection against electric shock - Supplementary equipotential b onding
|
Technical
|
212651
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
6.3.3.3
|
SWIMMING POOLS, PADDLING POOLS AND SPA POOLS OR TUBS - Protection against electric shock - Voltage gradients
|
Unsafe
|
211653
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
6.3.4.1
|
SWIMMING POOLS, PADDLING POOLS AND SPA POOLS OR TUBS - Selection and installation of electrical equipment - Degree of pr otection required
|
Technical
|
211654
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
6.3.4.2
|
SWIMMING POOLS, PADDLING POOLS AND SPA POOLS OR TUBS - Selection and installation of electrical equipment - Wiring syste ms
|
Technical
|
211655
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
6.3.4.3
|
SWIMMING POOLS, PADDLING POOLS AND SPA POOLS OR TUBS - Selection and installation of electrical equipment - Socket-outle ts
|
Technical
|
211656
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
6.3.4.4
|
SWIMMING POOLS, PADDLING POOLS AND SPA POOLS OR TUBS - Selection and installation of electrical equipment - Switches and other accessories
|
Technical
|
211658
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
6.3.4.6
|
SWIMMING POOLS, PADDLING POOLS AND SPA POOLS OR TUBS - Selection and installation of electrical equipment - Switchboards
|
Technical
|
211659
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
6.3.4.7
|
SWIMMING POOLS, PADDLING POOLS AND SPA POOLS OR TUBS - Selection and installation of electrical equipment - Electricity generation systems
|
Technical
|
211660
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
6.3.4.8
|
SWIMMING POOLS, PADDLING POOLS AND SPA POOLS OR TUBS - Selection and installation of electrical equipment - Electricity distributor's electrical equipment
|
Technical
|
211662
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
6.4.2
|
FOUNTAINS AND WATER FEATURES - Classification of zones
|
Technical
|
211664
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
6.4.3.1
|
FOUNTAINS AND WATER FEATURES - Protection against electric shock - Use of SELV
|
Technical
|
212667
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
6.4.3.2.2
|
FOUNTAINS AND WATER FEATURES - Protection against electric shock - Prohibited measures
|
Unsafe
|
211669
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
6.4.4.1
|
FOUNTAINS AND WATER FEATURES - Selection and installation of electrical equipment - Degree of protection required
|
Technical
|
211670
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
6.4.4.2
|
FOUNTAINS AND WATER FEATURES - Selection and installation of electrical equipment - Wiring systems
|
Technical
|
211671
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
6.4.4.3
|
FOUNTAINS AND WATER FEATURES - Selection and installation of electrical equipment - Socket-outlets
|
Technical
|
211672
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
6.4.4.4
|
FOUNTAINS AND WATER FEATURES - Selection and installation of electrical equipment - Switches and other accessories
|
Technical
|
211674
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
6.4.4.6
|
FOUNTAINS AND WATER FEATURES - Selection and installation of electrical equipment - Switchboards
|
Technical
|
211675
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
6.4.4.7
|
FOUNTAINS AND WATER FEATURES - Selection and installation of electrical equipment - Electricity generation systems
|
Technical
|
211676
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
6.4.4.8
|
FOUNTAINS AND WATER FEATURES - Selection and installation of electrical equipment - Electricity distributor's electrical equipment
|
Technical
|
211678
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
6.5.2
|
SAUNAS - Classification of zones
|
Technical
|
211680
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
6.5.3.1
|
SAUNAS - Protection against electric shock - Use of SELV
|
Technical
|
212681
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
6.5.3.2
|
SAUNAS - Protection against electric shock - Prohibited measures
|
Unsafe
|
211684
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
6.5.4.1
|
SAUNAS - Selection and installation of electrical equipment - Degree of protection required
|
Technical
|
211685
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
6.5.4.2
|
SAUNAS - Selection and installation of electrical equipment - Requirements in classified zones
|
Technical
|
211686
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
6.5.4.3
|
SAUNAS - Selection and installation of electrical equipment - Wiring systems
|
Technical
|
211687
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
6.5.4.4
|
SAUNAS - Selection and installation of electrical equipment - Socket-outlets, switches and other accessories
|
Technical
|
211688
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
6.5.4.5
|
SAUNAS - Selection and installation of electrical equipment - Sauna heating appliances
|
Technical
|
211689
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
6.5.4.6
|
SAUNAS - Selection and installation of electrical equipment - Switchboards
|
Technical
|
211692
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
6.6.2.1
|
REFRIGERATION ROOMS - Protection against electric shock - Use of SELV
|
Technical
|
212693
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
6.6.2.2
|
REFRIGERATION ROOMS - Protection against electric shock - Prohibited measures
|
Unsafe
|
211695
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
6.6.3.1
|
REFRIGERATION ROOMS - Selection and installation of electrical equipment - Degree of protection required
|
Technical
|
211696
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
6.6.3.2
|
REFRIGERATION ROOMS - Selection and installation of electrical equipment - Wiring systems
|
Technical
|
211697
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
6.6.3.2.1
|
REFRIGERATION ROOMS - Selection and installation of electrical equipment - General
|
Technical
|
211698
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
6.6.3.2.2
|
REFRIGERATION ROOMS - Selection and installation of electrical equipment - Types permitted
|
Technical
|
211699
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
6.6.3.2.3
|
REFRIGERATION ROOMS - Selection and installation of electrical equipment - Sealing
|
Technical
|
211700
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
6.6.3.3
|
REFRIGERATION ROOMS - Selection and installation of electrical equipment - Socket-outlets, switches and other accessorie s
|
Technical
|
211702
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
6.6.3.4.1
|
REFRIGERATION ROOMS - Selection and installation of electrical equipment - Luminaires
|
Technical
|
211703
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
6.6.3.4.2
|
REFRIGERATION ROOMS - Selection and installation of electrical equipment - Lampholders
|
Technical
|
211704
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
6.6.3.5
|
REFRIGERATION ROOMS - Selection and installation of electrical equipment - Fixed appliances and motors
|
Technical
|
211705
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
6.6.3.6
|
REFRIGERATION ROOMS - Selection and installation of electrical equipment - Heating elements in door seals
|
Technical
|
211706
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
6.6.3.7
|
REFRIGERATION ROOMS - Selection and installation of electrical equipment - Switchboards
|
Technical
|
211708
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
6.7.2
|
SANITISATION AND HOSING DOWN OPERATIONS - Classification of zone
|
Technical
|
211710
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
6.7.3.1
|
SANITISATION AND HOSING DOWN OPERATIONS - Protection against electric shock - Use of SELV
|
Technical
|
212711
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
6.7.3.2
|
SANITISATION AND HOSING DOWN OPERATIONS - Protection against electric shock - Prohibited measures
|
Unsafe
|
211713
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
6.7.4.1
|
SANITISATION AND HOSING DOWN OPERATIONS - Selection and installation of electrical equipment - Degree of protection requ ired
|
Technical
|
211714
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
6.7.4.2
|
SANITISATION AND HOSING DOWN OPERATIONS - Selection and installation of electrical equipment - Electrical equipment
|
Technical
|
211715
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
6.7.4.3
|
SANITISATION AND HOSING DOWN OPERATIONS - Selection and installation of electrical equipment - Switchboards
|
Technical
|
211718
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.2.1.2
|
SAFETY SERVICES - General
|
Technical
|
211720
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.2.2.1
|
SAFETY SERVICES - Supply systems - General
|
Technical
|
211722
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.2.2.2.1
|
SAFETY SERVICES - Wiring systems - WS classification provided
|
Technical
|
211723
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.2.2.2.2
|
SAFETY SERVICES - Wiring systems - WS classification is not provided
|
Technical
|
211725
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.2.2.3.1
|
SAFETY SERVICES - Alternative supply systems - Continued occupation
|
Technical
|
211726
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.2.2.3.2
|
SAFETY SERVICES - Alternative supply systems - Fire management system
|
Technical
|
211728
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.2.3.1
|
SAFETY SERVICES - Main switchboard and switchgear - General
|
Technical
|
211729
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.2.3.2
|
SAFETY SERVICES - Main switchboard and switchgear - Switchgear
|
Technical
|
211730
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.2.3.3
|
SAFETY SERVICES - Main switchboard and switchgear - Cables in the same enclosure
|
Technical
|
211731
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.2.3.4
|
SAFETY SERVICES - Main switchboard and switchgear - Arrangement
|
Technical
|
211732
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.2.3.5
|
SAFETY SERVICES - Main switchboard and switchgear - Discrimination (selectivity) of circuit-protective devices
|
Technical
|
211734
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.2.4.1
|
SAFETY SERVICES - Main switches - General
|
Technical
|
211735
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.2.4.2
|
SAFETY SERVICES - Main switches - Arrangement of main switches
|
Technical
|
211736
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.2.4.3
|
SAFETY SERVICES - Main switches - Mechanical protection
|
Technical
|
211737
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.2.4.4
|
SAFETY SERVICES - Main switches - Identification
|
Technical
|
211738
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.2.4.5
|
SAFETY SERVICES - Main switches - Electrical installations in outbuildings
|
Technical
|
211739
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.2.4.6
|
SAFETY SERVICES - Main switches - Fire separated portions of a building
|
Technical
|
211741
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.2.5.1
|
SAFETY SERVICES - Fire pumps and fire pump control equipment - General
|
Technical
|
211743
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.2.5.2.1
|
SAFETY SERVICES - Fire pumps and fire pump control equipment - Types of wiring systems
|
Technical
|
211744
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.2.5.2.2
|
SAFETY SERVICES - Fire pumps and fire pump control equipment - Segregation of cables
|
Technical
|
211745
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.2.5.3
|
SAFETY SERVICES - Fire pumps and fire pump control equipment - Switchgear for fire pumps and fire pump control equipment
|
Technical
|
211746
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.2.5.4
|
SAFETY SERVICES - Fire pumps and fire pump control equipment - Interposing switches for fire pumps and fire pump control equipment
|
Technical
|
211747
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.2.5.5
|
SAFETY SERVICES - Fire pumps and fire pump control equipment - Pump rooms for fire pumps and fire pump control equipment
|
Technical
|
211748
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.2.5.6
|
SAFETY SERVICES - Fire pumps and fire pump control equipment - Fire-pump motors
|
Technical
|
211749
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.2.5.6.1
|
SAFETY SERVICES - Fire pumps and fire pump control equipment - Isolating switches for fire-pump motors
|
Technical
|
211750
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.2.5.6.2
|
SAFETY SERVICES - Fire pumps and fire pump control equipment - Overcurrent protection for fire-pump motors
|
Technical
|
211751
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.2.5.6.3
|
SAFETY SERVICES - Fire pumps and fire pump control equipment - Overtemperature protection for fire-pump motors
|
Technical
|
211752
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.2.5.6.4
|
SAFETY SERVICES - Fire pumps and fire pump control equipment - Control circuits for fire-pump motors
|
Technical
|
211754
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.2.6.1
|
SAFETY SERVICES - Fire and smoke detection equipment and fire alarm systems - General
|
Technical
|
211756
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.2.6.2.1
|
SAFETY SERVICES - Fire and smoke detection equipment and fire alarm systems - Types of wiring systems for fire detection and alarm systems
|
Technical
|
211757
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.2.6.2.2
|
SAFETY SERVICES - Fire and smoke detection equipment and fire alarm systems - Segregation of cables for fire detection a nd alarm systems
|
Technical
|
211758
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.2.6.3
|
SAFETY SERVICES - Fire and smoke detection equipment and fire alarm systems - Interposing switches for fire detection an d alarm systems
|
Technical
|
211760
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.2.7.1
|
SAFETY SERVICES - Air-handling systems - General
|
Technical
|
211762
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.2.7.2.1
|
SAFETY SERVICES - Air-handling systems - Types of wiring system for air-handling systems
|
Technical
|
211763
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.2.7.2.2
|
SAFETY SERVICES - Air-handling systems - Segregation of cables for air-handling systems
|
Technical
|
211764
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.2.7.2.3
|
SAFETY SERVICES - Air-handling systems - Interposing switches for air-handling systems
|
Technical
|
211766
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.2.8.1
|
SAFETY SERVICES - Evacuation equipment - General
|
Technical
|
211768
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.2.8.2.1
|
SAFETY SERVICES - Evacuation equipment - Types of wiring system for evacuation equipment
|
Technical
|
211769
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.2.8.2.2
|
SAFETY SERVICES - Evacuation equipment - Segregation of cables for evacuation equipment
|
Technical
|
211770
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.2.8.3
|
SAFETY SERVICES - Evacuation equipment - Interposing switches for evacuation equipment
|
Technical
|
211773
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.2.9.1.1
|
SAFETY SERVICES - Emergency lifts - General - In Australia
|
Technical
|
212774
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.2.9.2
|
SAFETY SERVICES - Emergency lifts - Control and protection
|
Technical
|
211776
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.2.9.3.1
|
SAFETY SERVICES - Emergency lifts - Types of wiring system for emergency lifts
|
Technical
|
211777
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.2.9.3.2
|
SAFETY SERVICES - Emergency lifts - Segregation of cables
|
Technical
|
211778
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.2.9.4
|
SAFETY SERVICES - Emergency lifts - Interposing switches
|
Technical
|
211779
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.2.9.5
|
SAFETY SERVICES - Emergency lifts - Switchgear
|
Technical
|
211781
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.2.10.1
|
SAFETY SERVICES - Emergency motor-room-less lifts - General
|
Technical
|
211782
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.2.10.2
|
SAFETY SERVICES - Emergency motor-room-less lifts -Switchboards
|
Technical
|
211783
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.2.10.3
|
SAFETY SERVICES - Emergency motor-room-less lifts - Switchgear
|
Technical
|
211785
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.2.10.4.1
|
SAFETY SERVICES - Emergency motor-room-less lifts - Types of wiring systems for MRL lifts
|
Technical
|
211786
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.2.10.4.2
|
SAFETY SERVICES - Emergency motor-room-less lifts - Segregation of cables
|
Technical
|
211788
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.3.1
|
ELECTRICITY GENERATION SYSTEMS - General
|
Technical
|
211789
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.3.2
|
ELECTRICITY GENERATION SYSTEMS - Selection and installation of system
|
Technical
|
211790
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.3.3
|
ELECTRICITY GENERATION SYSTEMS - Control
|
Technical
|
211794
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.3.4.2
|
ELECTRICITY GENERATION SYSTEMS - Isolation - Electricity generation systems incorporating batteries
|
Technical
|
211796
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.3.5.1
|
ELECTRICITY GENERATION SYSTEMS - Overcurrent protection - Electricity generation system protection
|
Technical
|
211798
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.3.5.2.1
|
ELECTRICITY GENERATION SYSTEMS - Circuit protection - General
|
Technical
|
211799
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.3.5.2.2
|
ELECTRICITY GENERATION SYSTEMS - Circuit protection - RCDs
|
Technical
|
211800
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.3.6
|
ELECTRICITY GENERATION SYSTEMS - Earthing
|
Technical
|
211801
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.3.7
|
ELECTRICITY GENERATION SYSTEMS - Connected electrical equipment
|
Technical
|
211804
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.3.8.1.1
|
ELECTRICITY GENERATION SYSTEMS - Connection to electrical installation - Alternative supplies - General
|
Technical
|
211805
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.3.8.1.2
|
ELECTRICITY GENERATION SYSTEMS - Connection to electrical installation - Alternative supplies - Switching
|
Technical
|
211807
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.3.8.2.1
|
ELECTRICITY GENERATION SYSTEMS - Grid-connected inverter systems - General
|
Technical
|
211808
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.3.8.2.2
|
ELECTRICITY GENERATION SYSTEMS - Grid-connected inverter systems - Switching
|
Technical
|
211809
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.3.8.2.3
|
ELECTRICITY GENERATION SYSTEMS - Grid-connected inverter systems - Connection
|
Technical
|
211811
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.3.8.3.1
|
ELECTRICITY GENERATION SYSTEMS - Stand-alone power systems - General
|
Technical
|
211812
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.3.8.3.2
|
ELECTRICITY GENERATION SYSTEMS - Stand-alone power systems - Switching
|
Technical
|
211813
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.3.8.3.3
|
ELECTRICITY GENERATION SYSTEMS - Stand-alone power systems - Connection
|
Technical
|
211815
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.4.1
|
PROTECTION BY ELECTRICAL SEPARATION (ISOLATED SUPPLY) - General
|
Technical
|
211816
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.4.2
|
PROTECTION BY ELECTRICAL SEPARATION (ISOLATED SUPPLY) - Source of supply
|
Technical
|
211817
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.4.3
|
PROTECTION BY ELECTRICAL SEPARATION (ISOLATED SUPPLY) - Arrangement of circuits
|
Technical
|
211818
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.4.4
|
PROTECTION BY ELECTRICAL SEPARATION (ISOLATED SUPPLY) - Switching devices
|
Technical
|
211819
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.4.5
|
PROTECTION BY ELECTRICAL SEPARATION (ISOLATED SUPPLY) - Supply to single item of electrical equipment
|
Technical
|
211820
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.4.6
|
PROTECTION BY ELECTRICAL SEPARATION (ISOLATED SUPPLY) - Supply to multiple items of electrical equipment
|
Technical
|
211821
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.4.7
|
PROTECTION BY ELECTRICAL SEPARATION (ISOLATED SUPPLY) - Variable speed drive (VSD) EMI filters
|
Technical
|
213823
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.4.8.1
|
PROTECTION BY ELECTRICAL SEPARATION (ISOLATED SUPPLY) - Testing - General
|
Testing
|
213824
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.4.8.2
|
PROTECTION BY ELECTRICAL SEPARATION (ISOLATED SUPPLY) - Testing- Single items of electrical equipment
|
Testing
|
213825
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.4.8.3
|
PROTECTION BY ELECTRICAL SEPARATION (ISOLATED SUPPLY) - Testing- Multiple items of electrical equipment
|
Testing
|
213826
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.4.8.4
|
PROTECTION BY ELECTRICAL SEPARATION (ISOLATED SUPPLY) - Testing - Bonding conductor continuity
|
Testing
|
211828
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.5.2
|
EXTRA-LOW VOLTAGE ELECTRICAL INSTALLATIONS - Application
|
Technical
|
211829
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.5.3
|
EXTRA-LOW VOLTAGE ELECTRICAL INSTALLATIONS - Sources of supply to SELV and PELV systems
|
Technical
|
211830
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.5.4
|
EXTRA-LOW VOLTAGE ELECTRICAL INSTALLATIONS - Separation requirements for SELV and PELV circuits
|
Technical
|
211831
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.5.5
|
EXTRA-LOW VOLTAGE ELECTRICAL INSTALLATIONS - Arrangement of SELV circuits
|
Technical
|
211832
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.5.6
|
EXTRA-LOW VOLTAGE ELECTRICAL INSTALLATIONS - Arrangement of PELV circuits
|
Technical
|
211833
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.5.7
|
EXTRA-LOW VOLTAGE ELECTRICAL INSTALLATIONS - Voltage drop in conductors
|
Technical
|
211835
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.5.8.1
|
EXTRA-LOW VOLTAGE ELECTRICAL INSTALLATIONS - Control of an electrical installation - Main switches
|
Technical
|
211836
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.5.8.2
|
EXTRA-LOW VOLTAGE ELECTRICAL INSTALLATIONS - Control of an electrical installation - Other switches
|
Technical
|
211838
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.5.9.1
|
EXTRA-LOW VOLTAGE ELECTRICAL INSTALLATIONS - Overcurrent protection - General
|
Technical
|
211839
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.5.9.2
|
EXTRA-LOW VOLTAGE ELECTRICAL INSTALLATIONS - Overcurrent protection - Omission of overcurrent protection
|
Technical
|
211840
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.5.10
|
EXTRA-LOW VOLTAGE ELECTRICAL INSTALLATIONS - Connecting devices
|
Technical
|
211842
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.5.11.1
|
EXTRA-LOW VOLTAGE ELECTRICAL INSTALLATIONS - Wiring systems - General
|
Technical
|
211843
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.5.11.2
|
EXTRA-LOW VOLTAGE ELECTRICAL INSTALLATIONS - Wiring systems - Aerial conductors
|
Technical
|
211844
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.5.11.3
|
EXTRA-LOW VOLTAGE ELECTRICAL INSTALLATIONS - Wiring systems - Underground conductors
|
Technical
|
213846
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.5.12.1
|
EXTRA-LOW VOLTAGE ELECTRICAL INSTALLATIONS - Testing - General
|
Testing
|
213847
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.5.12.2
|
EXTRA-LOW VOLTAGE ELECTRICAL INSTALLATIONS - Testing - Protection by SELV
|
Testing
|
213848
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.5.12.3
|
EXTRA-LOW VOLTAGE ELECTRICAL INSTALLATIONS - Testing - Protection by PELV
|
Testing
|
211850
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.6.2
|
HIGH VOLTAGE ELECTRICAL INSTALLATIONS - Application
|
Technical
|
211851
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.6.2.1
|
HIGH VOLTAGE ELECTRICAL INSTALLATIONS - In Australia
|
Technical
|
211852
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.6.3
|
HIGH VOLTAGE ELECTRICAL INSTALLATIONS - Issues relevant to high voltage installations
|
Technical
|
211854
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.7.2
|
HAZARDOUS AREAS (EXPLOSIVE GAS OR COMBUSTIBLE DUSTS) - Classification of hazardous areas
|
Technical
|
211855
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.7.2.1
|
HAZARDOUS AREAS (EXPLOSIVE GAS OR COMBUSTIBLE DUSTS) - Responsibility for classification
|
Technical
|
211856
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.7.2.2
|
HAZARDOUS AREAS (EXPLOSIVE GAS OR COMBUSTIBLE DUSTS) - Hazardous areas (AS/NZS 60079 series)
|
Technical
|
211857
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.7.2.3
|
HAZARDOUS AREAS (EXPLOSIVE GAS OR COMBUSTIBLE DUSTS) - Reduction or elimination of the hazard
|
Technical
|
211858
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.7.2.4
|
HAZARDOUS AREAS (EXPLOSIVE GAS OR COMBUSTIBLE DUSTS) - Electrical equipment
|
Technical
|
211859
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.7.2.4.1
|
HAZARDOUS AREAS (EXPLOSIVE GAS OR COMBUSTIBLE DUSTS) - Selection
|
Technical
|
211860
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.7.2.4.2
|
HAZARDOUS AREAS (EXPLOSIVE GAS OR COMBUSTIBLE DUSTS) - Installation
|
Technical
|
211864
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.8.2.1
|
AS/NZS 3012 Construction and demolition sites
|
Technical
|
211865
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.8.2.2
|
AS/NZS 3003 Electro medical treatment areas
|
Technical
|
211866
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.8.2.3
|
AS/NZS 3001 Transportable structures and vehicles including their site supplies
|
Technical
|
211867
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.8.2.4
|
AS/NZS 3004 Marinas and recreational boats
|
Technical
|
211868
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.8.2.5
|
AS/NZS 3002 Shows and carnivals
|
Technical
|
211869
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.8.2.6
|
AS/NZS 3015 Telecommunication network power supplies
|
Technical
|
211870
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.8.2.7
|
Cranes and hoists - shall be in accordance with the applicable requirements of this Standard
|
Technical
|
211871
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.8.2.8
|
Lifts - shall be in accordance with the applicable requirements of this Standard
|
Technical
|
211872
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.8.2.9
|
AS 2067 High voltage installations
|
Technical
|
211873
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.8.2.10
|
AS/NZS 3010 Generating sets
|
Technical
|
211874
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.8.2.11
|
AS/NZS 4777 series Inverters
|
Technical
|
211876
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.8.2.13
|
AS/NZS 4509 series - Stand-alone power systems
|
Technical
|
211877
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.8.2.14
|
AS/NZS 5033 Photovoltaic (PV) arrays
|
Technical
|
211878
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.8.2.15
|
AS/NZS 5139 and AS 3011 (series) - Secondary battery systems
|
Technical
|
211881
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.8.2.18
|
AS/NZS 60079.14 Explosive atmospheres and hazardous areas
|
Technical
|
211883
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
8.1.2
|
VERIFICATION - General requirements
|
Technical
|
211884
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
8.1.3
|
VERIFICATION - Periodic inspection and testing
|
Technical
|
211886
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
8.2.1
|
VISUAL INSPECTION - General
|
Technical
|
211887
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
8.2.2
|
VISUAL INSPECTION - Checklist
|
Technical
|
211889
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
8.3.1
|
TESTING - General
|
Technical
|
211892
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
8.3.3.1
|
TESTING - Low voltage
|
Technical
|
211893
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
8.3.3.2
|
TESTING - Extra-low voltage
|
Technical
|
211894
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
8.3.3.3
|
TESTING - Test failures
|
Technical
|
213897
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
8.3.5.1
|
TESTING - Continuity of the earthing system - General
|
Testing
|
213898
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
8.3.5.2
|
TESTING - Continuity of the earthing system - Results
|
Testing
|
213900
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
8.3.6.1
|
TESTING - Insulation resistance- General
|
Testing
|
213901
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
8.3.6.2
|
TESTING - Insulation resistance - Method
|
Testing
|
211910
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
8.3.9.1
|
TESTING - Verification of earth fault-loop impedance (EFLI) - Low voltage socket-outlet circuits
|
Technical
|
211912
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
8.3.9.2.1
|
TESTING - Verification of earth fault-loop impedance - Methods - General
|
Technical
|
213913
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
8.3.9.2.2
|
TESTING - Verification of earth fault-loop impedance - Supply available
|
Testing
|
213914
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
8.3.9.2.3
|
TESTING - Verification of earth fault-loop impedance - No supply available
|
Testing
|
213915
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
8.3.9.3
|
TESTING - Verification of earth fault-loop impedance - Results
|
Testing
|
211917
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
8.4
|
VERIFICATION RECORDS
|
Technical
|
811002
|
AS/NZS 3001:2008 Transportable structures and vehicles including their site supplies
|
2.1
|
SUPPLY ARRANGEMENTS
|
Technical
|
811003
|
AS/NZS 3001:2008 Transportable structures and vehicles including their site supplies
|
2.2.1
|
Supply from service pillar
|
Technical
|
811004
|
AS/NZS 3001:2008 Transportable structures and vehicles including their site supplies
|
2.2.2
|
Underground wiring providing site supply
|
Technical
|
811005
|
AS/NZS 3001:2008 Transportable structures and vehicles including their site supplies
|
2.2.3
|
Overhead wiring providing the site supply
|
Technical
|
811006
|
AS/NZS 3001:2008 Transportable structures and vehicles including their site supplies
|
2.2.4
|
Earthing - In Australia
|
Technical
|
811007
|
AS/NZS 3001:2008 Transportable structures and vehicles including their site supplies
|
2.2.5
|
Maximum demand
|
Technical
|
811008
|
AS/NZS 3001:2008 Transportable structures and vehicles including their site supplies
|
2.2.6
|
Caravan park service pillars
|
Technical
|
811009
|
AS/NZS 3001:2008 Transportable structures and vehicles including their site supplies
|
2.2.7
|
Socket-outlets
|
Technical
|
811010
|
AS/NZS 3001:2008 Transportable structures and vehicles including their site supplies
|
2.2.8
|
Construction of caravan park service pillars
|
Technical
|
811011
|
AS/NZS 3001:2008 Transportable structures and vehicles including their site supplies
|
2.2.9
|
Other switchboards
|
Technical
|
811012
|
AS/NZS 3001:2008 Transportable structures and vehicles including their site supplies
|
2.2.10
|
Other socket-outlets
|
Technical
|
811013
|
AS/NZS 3001:2008 Transportable structures and vehicles including their site supplies
|
2.3.1
|
Supply from socket-outlet
|
Technical
|
811014
|
AS/NZS 3001:2008 Transportable structures and vehicles including their site supplies
|
2.3.2
|
Configuration and rating
|
Technical
|
811015
|
AS/NZS 3001:2008 Transportable structures and vehicles including their site supplies
|
2.3.3
|
Overload protection
|
Technical
|
811016
|
AS/NZS 3001:2008 Transportable structures and vehicles including their site supplies
|
2.3.4
|
Protection against earth leakage current
|
Technical
|
811017
|
AS/NZS 3001:2008 Transportable structures and vehicles including their site supplies
|
2.3.5
|
Control
|
Technical
|
811018
|
AS/NZS 3001:2008 Transportable structures and vehicles including their site supplies
|
2.3.6
|
Common overload, earth leakage and control device
|
Technical
|
811019
|
AS/NZS 3001:2008 Transportable structures and vehicles including their site supplies
|
2.3.7
|
Weatherproofing
|
Technical
|
811020
|
AS/NZS 3001:2008 Transportable structures and vehicles including their site supplies
|
2.3.8
|
Doors and covers
|
Technical
|
811021
|
AS/NZS 3001:2008 Transportable structures and vehicles including their site supplies
|
2.3.9
|
Strain relief
|
Technical
|
811022
|
AS/NZS 3001:2008 Transportable structures and vehicles including their site supplies
|
2.4.1
|
Requirements for portable generator sets or inverters
|
Technical
|
811023
|
AS/NZS 3001:2008 Transportable structures and vehicles including their site supplies
|
2.4.2
|
Overcurrent protection
|
Technical
|
811024
|
AS/NZS 3001:2008 Transportable structures and vehicles including their site supplies
|
2.4.3
|
Earth leakage protection
|
Technical
|
811025
|
AS/NZS 3001:2008 Transportable structures and vehicles including their site supplies
|
2.4.4
|
Combined overcurrent and earth leakage protection
|
Technical
|
811026
|
AS/NZS 3001:2008 Transportable structures and vehicles including their site supplies
|
2.6
|
SITES FOR LOW-CONSUMPTION TRANSPORTABLE STRUCTURES
|
Technical
|
811027
|
AS/NZS 3001:2008 Transportable structures and vehicles including their site supplies
|
2.7.1
|
Initial verification of the installation
|
Technical
|
811028
|
AS/NZS 3001:2008 Transportable structures and vehicles including their site supplies
|
3.2.1
|
PROVISION FOR CONNECTION TO SITE SUPPLY - General
|
Technical
|
811029
|
AS/NZS 3001:2008 Transportable structures and vehicles including their site supplies
|
3.2.2
|
Detachable connection at the transportable structure or vehicle
|
Technical
|
811030
|
AS/NZS 3001:2008 Transportable structures and vehicles including their site supplies
|
3.2.3
|
Permanent connection of the supply lead
|
Technical
|
811031
|
AS/NZS 3001:2008 Transportable structures and vehicles including their site supplies
|
3.2.4
|
Multiple connections
|
Technical
|
811032
|
AS/NZS 3001:2008 Transportable structures and vehicles including their site supplies
|
3.3
|
CONTROL AND PROTECTION
|
Technical
|
811033
|
AS/NZS 3001:2008 Transportable structures and vehicles including their site supplies
|
3.3.1
|
Overcurrent protection
|
Technical
|
811034
|
AS/NZS 3001:2008 Transportable structures and vehicles including their site supplies
|
3.3.2
|
Protection against earth leakage current
|
Technical
|
811035
|
AS/NZS 3001:2008 Transportable structures and vehicles including their site supplies
|
3.3.3
|
Location
|
Technical
|
811036
|
AS/NZS 3001:2008 Transportable structures and vehicles including their site supplies
|
3.3.4
|
Prohibited equipment
|
Technical
|
811037
|
AS/NZS 3001:2008 Transportable structures and vehicles including their site supplies
|
3.4.1
|
WIRING SYSTEM - Size and type of cable
|
Technical
|
811038
|
AS/NZS 3001:2008 Transportable structures and vehicles including their site supplies
|
3.4.2
|
Protection from damage
|
Technical
|
811039
|
AS/NZS 3001:2008 Transportable structures and vehicles including their site supplies
|
3.4.3
|
Fixing
|
Technical
|
811040
|
AS/NZS 3001:2008 Transportable structures and vehicles including their site supplies
|
3.4.4
|
Isolation and segregation
|
Technical
|
811041
|
AS/NZS 3001:2008 Transportable structures and vehicles including their site supplies
|
3.5.1
|
EARTHING - Detachable connection, General
|
Technical
|
811042
|
AS/NZS 3001:2008 Transportable structures and vehicles including their site supplies
|
3.5.2
|
Equipotential bonding
|
Technical
|
811043
|
AS/NZS 3001:2008 Transportable structures and vehicles including their site supplies
|
3.6.1
|
ACCESSORIES - Mounting
|
Technical
|
811044
|
AS/NZS 3001:2008 Transportable structures and vehicles including their site supplies
|
3.6.2
|
Switches
|
Technical
|
811045
|
AS/NZS 3001:2008 Transportable structures and vehicles including their site supplies
|
3.6.3
|
Socket-outlets
|
Technical
|
811046
|
AS/NZS 3001:2008 Transportable structures and vehicles including their site supplies
|
3.7.1
|
PERMANENTLY CONNECTED APPLIANCES - Control
|
Technical
|
811047
|
AS/NZS 3001:2008 Transportable structures and vehicles including their site supplies
|
3.7.2
|
Over-temperature cut-out
|
Technical
|
811048
|
AS/NZS 3001:2008 Transportable structures and vehicles including their site supplies
|
3.9
|
ELECTRICAL INSTALLATIONS IN DAMP AREAS
|
Technical
|
811049
|
AS/NZS 3001:2008 Transportable structures and vehicles including their site supplies
|
3.10.1
|
Initial verification of the installation
|
Technical
|
811050
|
AS/NZS 3001:2008 Transportable structures and vehicles including their site supplies
|
4.1
|
GENERAL
|
Technical
|
811051
|
AS/NZS 3001:2008 Transportable structures and vehicles including their site supplies
|
4.2.1
|
SUPPLY TO ELECTRICAL EQUIPMENT - One item to be supplied
|
Technical
|
811052
|
AS/NZS 3001:2008 Transportable structures and vehicles including their site supplies
|
4.2.2
|
More than one item to be supplied
|
Technical
|
811053
|
AS/NZS 3001:2008 Transportable structures and vehicles including their site supplies
|
4.3.1
|
CONNECTION OF SUPPLY - General
|
Technical
|
811054
|
AS/NZS 3001:2008 Transportable structures and vehicles including their site supplies
|
4.3.2
|
Multiple transportable structures occupying the one site
|
Technical
|
811055
|
AS/NZS 3001:2008 Transportable structures and vehicles including their site supplies
|
4.3.3
|
Restriction on connection
|
Technical
|
811056
|
AS/NZS 3001:2008 Transportable structures and vehicles including their site supplies
|
4.3.4
|
Prohibited connections
|
Technical
|
811057
|
AS/NZS 3001:2008 Transportable structures and vehicles including their site supplies
|
4.4.1
|
OUTLET BOX - General
|
Technical
|
811058
|
AS/NZS 3001:2008 Transportable structures and vehicles including their site supplies
|
4.4.2
|
Construction
|
Technical
|
811059
|
AS/NZS 3001:2008 Transportable structures and vehicles including their site supplies
|
4.4.3
|
Termination of supply lead
|
Technical
|
811060
|
AS/NZS 3001:2008 Transportable structures and vehicles including their site supplies
|
4.4.4
|
Socket-outlets
|
Technical
|
811061
|
AS/NZS 3001:2008 Transportable structures and vehicles including their site supplies
|
4.4.5
|
Earthing
|
Technical
|
811062
|
AS/NZS 3001:2008 Transportable structures and vehicles including their site supplies
|
4.4.6
|
Overcurrent protection
|
Technical
|
811063
|
AS/NZS 3001:2008 Transportable structures and vehicles including their site supplies
|
4.4.7
|
Protection against earth leakage current
|
Technical
|
811064
|
AS/NZS 3001:2008 Transportable structures and vehicles including their site supplies
|
4.4.8
|
Control switches
|
Technical
|
811065
|
AS/NZS 3001:2008 Transportable structures and vehicles including their site supplies
|
4.4.9
|
Marking
|
Technical
|
811066
|
AS/NZS 3001:2008 Transportable structures and vehicles including their site supplies
|
4.4.10
|
LIGHTING
|
Technical
|
811067
|
AS/NZS 3001:2008 Transportable structures and vehicles including their site supplies
|
4.5.1
|
Handlamps
|
Technical
|
811068
|
AS/NZS 3001:2008 Transportable structures and vehicles including their site supplies
|
4.5.2
|
Lighting equipment other than handlamps
|
Technical
|
811069
|
AS/NZS 3001:2008 Transportable structures and vehicles including their site supplies
|
5.1.1
|
SUPPLY LEAD - General
|
Technical
|
811070
|
AS/NZS 3001:2008 Transportable structures and vehicles including their site supplies
|
5.1.2
|
Technical details
|
Technical
|
811071
|
AS/NZS 3001:2008 Transportable structures and vehicles including their site supplies
|
5.1.3
|
Length
|
Technical
|
811072
|
AS/NZS 3001:2008 Transportable structures and vehicles including their site supplies
|
5.1.4
|
Coiled leads
|
Technical
|
811073
|
AS/NZS 3001:2008 Transportable structures and vehicles including their site supplies
|
5.2
|
INSTALLATION OF SUPPLY LEAD
|
Technical
|
831001
|
AS/NZS 3004.1:2014 Electrical installations - Marinas and boats Marinas
|
2.1.1
|
WIRING DETAILS - General
|
Technical
|
831002
|
AS/NZS 3004.1:2014 Electrical installations - Marinas and boats Marinas
|
2.1.2
|
Selection of electrical wiring systems
|
Technical
|
831003
|
AS/NZS 3004.1:2014 Electrical installations - Marinas and boats Marinas
|
2.1.3
|
Earthing system
|
Technical
|
831004
|
AS/NZS 3004.1:2014 Electrical installations - Marinas and boats Marinas
|
2.2
|
MAXIMUM DEMAND OF MAINS AND SUBMAINS
|
Technical
|
831005
|
AS/NZS 3004.1:2014 Electrical installations - Marinas and boats Marinas
|
2.3.1
|
ISOLATING TRANSFORMERS- General
|
Technical
|
831006
|
AS/NZS 3004.1:2014 Electrical installations - Marinas and boats Marinas
|
2.3.2
|
Protection
|
Technical
|
831007
|
AS/NZS 3004.1:2014 Electrical installations - Marinas and boats Marinas
|
2.4.1
|
SWITCHBOARDS PROVIDING LOW-VOLTAGE ELECTRICAL SUPPLY TO BOATS - General
|
Technical
|
831008
|
AS/NZS 3004.1:2014 Electrical installations - Marinas and boats Marinas
|
2.4.2
|
Service pillars
|
Technical
|
831009
|
AS/NZS 3004.1:2014 Electrical installations - Marinas and boats Marinas
|
2.4.3
|
Other switchboards
|
Technical
|
831010
|
AS/NZS 3004.1:2014 Electrical installations - Marinas and boats Marinas
|
2.5
|
OTHER SOCKET-OUTLETS
|
Technical
|
831011
|
AS/NZS 3004.1:2014 Electrical installations - Marinas and boats Marinas
|
3.1.1
|
SUPPLY LEAD - General
|
Technical
|
831012
|
AS/NZS 3004.1:2014 Electrical installations - Marinas and boats Marinas
|
3.1.2
|
Coiled leads
|
Technical
|
831013
|
AS/NZS 3004.1:2014 Electrical installations - Marinas and boats Marinas
|
3.2
|
INSTALLATION OF SUPPLY LEAD
|
Technical
|
831014
|
AS/NZS 3004.1:2014 Electrical installations - Marinas and boats Marinas
|
3.3.1
|
EARTHING - General
|
Technical
|
831015
|
AS/NZS 3004.1:2014 Electrical installations - Marinas and boats Marinas
|
3.3.2
|
Supply through a shore-mounted isolating transformer
|
Technical
|
831016
|
AS/NZS 3004.1:2014 Electrical installations - Marinas and boats Marinas
|
3.3.3
|
Supply through an on-board isolating transformer
|
Technical
|
831017
|
AS/NZS 3004.1:2014 Electrical installations - Marinas and boats Marinas
|
3.3.4
|
Supply without an isolating transformer
|
Technical
|
831018
|
AS/NZS 3004.1:2014 Electrical installations - Marinas and boats Marinas
|
4.1
|
GENERAL
|
Technical
|
833019
|
AS/NZS 3004.1:2014 Electrical installations - Marinas and boats Marinas
|
4.2.1
|
PERIODIC VERIFICATION - Testing
|
Testing
|
831020
|
AS/NZS 3004.1:2014 Electrical installations - Marinas and boats Marinas
|
4.2.2
|
Recording of results
|
Technical
|
611001
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
2.1
|
GENERAL
|
Technical
|
611002
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
2.1.1
|
Scope of Section
|
Technical
|
611003
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
2.1.2
|
Rating classifications
|
Technical
|
611004
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
2.1.3
|
Selection of generating set rating
|
Technical
|
611005
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
2.1.4
|
Generating set system of supply
|
Technical
|
611006
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
2.2
|
LOCATION
|
Technical
|
611007
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
2.3
|
MECHANICAL AND THERMAL PROTECTION
|
Technical
|
611008
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
2.3.1
|
Protection from mechanical damage
|
Technical
|
611009
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
2.3.2
|
Protection from moving parts
|
Technical
|
611010
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
2.3.3
|
Protection against thermal effects
|
Technical
|
611011
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
2.3.4
|
Protection against fuel leakage
|
Technical
|
611012
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
2.4
|
CONTROL OF GENERATING SET
|
Technical
|
611013
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
2.4.1
|
General
|
Technical
|
611014
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
2.4.2
|
Prime mover isolating devices
|
Technical
|
611015
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
2.4.2.1
|
Operation
|
Technical
|
611016
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
2.4.2.2
|
Location
|
Technical
|
611017
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
2.4.3
|
Synchronization
|
Technical
|
611018
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
2.4.4
|
Starting batteries and battery charging
|
Technical
|
611019
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
2.5
|
EARTHING ARRANGEMENTS
|
Technical
|
611020
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
2.6
|
ELECTRICAL INSTALLATION
|
Technical
|
611021
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
2.6.1
|
General requirements
|
Technical
|
611022
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
2.6.1.1
|
General
|
Technical
|
611023
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
2.6.1.2
|
Isolation from the normal supply system
|
Technical
|
611024
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
2.6.1.3
|
Generating set neutral conductor
|
Technical
|
611025
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
2.6.2
|
Overcurrent protection
|
Technical
|
611026
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
2.6.3
|
Generator output isolator
|
Technical
|
611027
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
2.7
|
ALTERNATIVE SUPPLY (STANDBY)
|
Technical
|
611028
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
2.7.1
|
General
|
Technical
|
611029
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
2.7.2
|
Operation
|
Technical
|
611030
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
2.7.3
|
Interlocking
|
Technical
|
611031
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
2.7.4
|
Changeover device with intermediate ?off? position
|
Technical
|
611032
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
2.7.5
|
Changeover device without an intermediate ?off? position
|
Technical
|
611033
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
2.7.6
|
Rating
|
Technical
|
611034
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
2.7.7
|
Access
|
Technical
|
611035
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
2.7.8
|
Identification
|
Technical
|
611036
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
2.7.9
|
Automatic changeover to normal supply
|
Technical
|
611037
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
2.7.10
|
Changeover device in the generator neutral
|
Technical
|
611038
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
2.7.10.1
|
In Australia
|
Technical
|
611039
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
2.7.11
|
Three pole/three pole changeover devices
|
Technical
|
611040
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
2.7.12
|
Three pole/four pole changeover devices
|
Technical
|
611041
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
2.7.13
|
Four pole/four pole changeover device
|
Technical
|
611042
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
2.8
|
EARTHING AND BONDING REQUIREMENTS
|
Technical
|
611043
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
2.8.1
|
General
|
Technical
|
611044
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
2.8.2
|
Earthing and bonding alterations to existing installations
|
Technical
|
611045
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
2.8.3
|
Generating set bonding system
|
Technical
|
611046
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
2.8.4
|
Generating set windings
|
Technical
|
611047
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
2.8.4.1
|
Multi-phase and single-phase three wire centre-tapped generating sets
|
Technical
|
611048
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
2.8.4.2
|
Single-phase portable generating sets
|
Technical
|
611049
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
2.8.5
|
Connection of generating set windings
|
Technical
|
611050
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
2.8.6
|
Arrangement of equipment
|
Technical
|
611051
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
2.8.7
|
Rating
|
Technical
|
611052
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
2.8.8
|
Provisions for securing isolating devices
|
Technical
|
611053
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
2.8.9
|
Indication of switch position
|
Technical
|
611054
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
2.9
|
GENERATOR SWITCHBOARDS
|
Technical
|
611055
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
2.1
|
LIGHTNING PROTECTION SYSTEMS
|
Technical
|
611056
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
2.11
|
GENERATING SETS CONNECTED AS NORMAL SUPPLY TO A MAIN SWITCHBOARD IN A PERMANENT ELECTRICAL INSTALLATION
|
Technical
|
611057
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
2.11.1
|
Generating set
|
Technical
|
611058
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
2.11.2
|
System of supply for generating set and main switchboard
|
Technical
|
611059
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
2.11.2.1
|
Overcurrent protection
|
Technical
|
611060
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
2.11.2.2
|
Connection to the electrical installation
|
Technical
|
611061
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
2.11.2.3
|
Earthing and equipotential bond connections
|
Technical
|
611062
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
2.11.2.4
|
Unsuitable electrical equipment
|
Technical
|
611063
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
2.11.2.5
|
Connection details
|
Technical
|
611064
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
2.11.3
|
Other systems of supply
|
Technical
|
611066
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
2.12.1
|
General
|
Technical
|
611067
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
2.12.2
|
System of supply for the generating set and switchboards
|
Technical
|
611068
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
2.12.2.1
|
Overcurrent protection
|
Technical
|
611069
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
2.12.2.2
|
Connection to switchboards
|
Technical
|
611070
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
3.1
|
GENERAL
|
Technical
|
611072
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
3.2.1
|
LOCATION - General
|
Technical
|
611073
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
3.2.2
|
Access space for generating sets
|
Technical
|
611074
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
3.2.3
|
Exit from generating set area
|
Technical
|
611075
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
3.2.3.1
|
General
|
Technical
|
611076
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
3.2.3.2
|
Number of openings
|
Technical
|
611077
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
3.2.3.3
|
Opening and locking of doors
|
Technical
|
611078
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
3.2.3.4
|
Size of doors and openings
|
Technical
|
611079
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
3.2.4
|
Ventilation
|
Technical
|
611080
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
3.2.5
|
Noise containment
|
Technical
|
611081
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
3.2.6
|
Lighting
|
Technical
|
611082
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
3.3
|
GUARDING OF LIVE PARTS
|
Technical
|
611083
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
3.3.1
|
General
|
Technical
|
611084
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
3.3.2
|
Walked on surfaces
|
Technical
|
611085
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
3.3.3
|
Outdoor locations
|
Technical
|
611086
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
3.4
|
TRANSFORMERS
|
Technical
|
611088
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
3.5.1
|
GENERATING SETS SUPPLYING SAFETY AND ESSENTIAL SERVICES - General
|
Technical
|
611089
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
3.5.2
|
GENERATING SETS SUPPLYING SAFETY AND ESSENTIAL SERVICES - Type
|
Technical
|
611090
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
3.5.3
|
GENERATING SETS SUPPLYING SAFETY AND ESSENTIAL SERVICES - Overcurrent protection
|
Technical
|
611091
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
3.5.4
|
GENERATING SETS SUPPLYING SAFETY AND ESSENTIAL SERVICES - Paralleling sources of supply
|
Technical
|
611092
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
3.5.5
|
GENERATING SETS SUPPLYING SAFETY AND ESSENTIAL SERVICES - Supply of other than safety services or essential services
|
Technical
|
611093
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
3.5.6
|
Automatic changeover to an emergency essential or supply system
|
Technical
|
611094
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
3.5.7
|
Switchgear
|
Technical
|
611095
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
4.1
|
GENERAL
|
Technical
|
611096
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
4.2
|
CONNECTION TO AN ELECTRICAL INSTALLATION
|
Technical
|
611097
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
4.2.1
|
General
|
Technical
|
611098
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
4.2.2
|
Connection to an installation
|
Technical
|
611099
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
4.2.3
|
Connection
|
Technical
|
611100
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
4.3
|
EARTHING AND BONDING
|
Technical
|
611101
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
4.3.1
|
General
|
Technical
|
611102
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
4.3.2
|
Connection of generating set windings
|
Technical
|
611103
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
4.3.2.1
|
Multi-phase and single-phase generating sets
|
Technical
|
611104
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
4.3.2.2
|
Earth electrode
|
Technical
|
841003
|
AS/NZS 3012:2019 +A1 Electrical installations - Construction and demolition sites
|
2.1.1
|
SUPPLY - Construction wiring
|
Technical
|
841004
|
AS/NZS 3012:2019 +A1 Electrical installations - Construction and demolition sites
|
2.1.2
|
SUPPLY - Appliances, luminaires and electrical equipment
|
Technical
|
841005
|
AS/NZS 3012:2019 +A1 Electrical installations - Construction and demolition sites
|
2.1.3
|
SUPPLY - Identification of source of supply
|
Technical
|
841006
|
AS/NZS 3012:2019 +A1 Electrical installations - Construction and demolition sites
|
2.1.4
|
SUPPLY - Connection devices
|
Technical
|
841007
|
AS/NZS 3012:2019 +A1 Electrical installations - Construction and demolition sites
|
2.1.5
|
SUPPLY - Polarization
|
Technical
|
841008
|
AS/NZS 3012:2019 +A1 Electrical installations - Construction and demolition sites
|
2.1.6
|
SUPPLY - Separate circuit requirements
|
Technical
|
841009
|
AS/NZS 3012:2019 +A1 Electrical installations - Construction and demolition sites
|
2.2
|
MAXIMUM DEMAND
|
Technical
|
841011
|
AS/NZS 3012:2019 +A1 Electrical installations - Construction and demolition sites
|
2.3.1.1
|
SWITCHBOARDS INSTALLED FOR THE PURPOSE OF CONSTRUCTION AND DEMOLITION - Location - General
|
Technical
|
841012
|
AS/NZS 3012:2019 +A1 Electrical installations - Construction and demolition sites
|
2.3.1.2
|
SWITCHBOARDS - Location - Multi-level buildings
|
Technical
|
841014
|
AS/NZS 3012:2019 +A1 Electrical installations - Construction and demolition sites
|
2.3.2.1
|
SWITCHBOARDS - Switchboard construction - General requirements
|
Technical
|
841015
|
AS/NZS 3012:2019 +A1 Electrical installations - Construction and demolition sites
|
2.3.2.2
|
SWITCHBOARDS - Switchboard construction - Assemblies for Construction sites (ACS) switchboard construction
|
Technical
|
841016
|
AS/NZS 3012:2019 +A1 Electrical installations - Construction and demolition sites
|
2.3.3
|
SWITCHBOARDS - Mounting of switchboards
|
Technical
|
841017
|
AS/NZS 3012:2019 +A1 Electrical installations - Construction and demolition sites
|
2.3.4
|
SWITCHBOARDS - Socket-outlets
|
Technical
|
841018
|
AS/NZS 3012:2019 +A1 Electrical installations - Construction and demolition sites
|
2.3.5
|
SWITCHBOARDS - Support of cables entering switchboards
|
Technical
|
841019
|
AS/NZS 3012:2019 +A1 Electrical installations - Construction and demolition sites
|
2.4.1
|
CONTROL AND PROTECTION - Control
|
Technical
|
841020
|
AS/NZS 3012:2019 +A1 Electrical installations - Construction and demolition sites
|
2.4.2
|
CONTROL AND PROTECTION - Securing of isolating switch
|
Technical
|
841021
|
AS/NZS 3012:2019 +A1 Electrical installations - Construction and demolition sites
|
2.4.3
|
CONTROL AND PROTECTION - Marking of isolating switches
|
Technical
|
841022
|
AS/NZS 3012:2019 +A1 Electrical installations - Construction and demolition sites
|
2.4.4
|
CONTROL AND PROTECTION - Size of marking
|
Technical
|
841023
|
AS/NZS 3012:2019 +A1 Electrical installations - Construction and demolition sites
|
2.4.5.1
|
CONTROL AND PROTECTION - Overload protection - Sub-mains
|
Technical
|
841024
|
AS/NZS 3012:2019 +A1 Electrical installations - Construction and demolition sites
|
2.4.5.2
|
CONTROL AND PROTECTION - Overload protection - Final sub-circuits
|
Technical
|
841027
|
AS/NZS 3012:2019 +A1 Electrical installations - Construction and demolition sites
|
2.4.6.3
|
CONTROL AND PROTECTION - Additional protection - Electrical equipment supplied by low-voltage generators
|
Technical
|
841028
|
AS/NZS 3012:2019 +A1 Electrical installations - Construction and demolition sites
|
2.4.6.4
|
CONTROL AND PROTECTION - Additional protection - Electrical equipment supplied by inverters
|
Technical
|
841029
|
AS/NZS 3012:2019 +A1 Electrical installations - Construction and demolition sites
|
2.4.6.5
|
CONTROL AND PROTECTION - Additional protection - Permanent wiring located where construction or demolition work may be c arried out
|
Technical
|
841030
|
AS/NZS 3012:2019 +A1 Electrical installations - Construction and demolition sites
|
2.4.7
|
CONTROL AND PROTECTION - Switching of single-phase socket-outlets
|
Technical
|
841031
|
AS/NZS 3012:2019 +A1 Electrical installations - Construction and demolition sites
|
2.5.1
|
CONSTRUCTION WIRING - Cables and fittings
|
Technical
|
841032
|
AS/NZS 3012:2019 +A1 Electrical installations - Construction and demolition sites
|
2.5.2
|
CONSTRUCTION WIRING - Installation of cables
|
Technical
|
841033
|
AS/NZS 3012:2019 +A1 Electrical installations - Construction and demolition sites
|
2.5.3
|
CONSTRUCTION WIRING - Protection against mechanical damage
|
Technical
|
841034
|
AS/NZS 3012:2019 +A1 Electrical installations - Construction and demolition sites
|
2.5.4
|
CONSTRUCTION WIRING - Marking
|
Technical
|
841035
|
AS/NZS 3012:2019 +A1 Electrical installations - Construction and demolition sites
|
2.5.5
|
CONSTRUCTION WIRING - Use of unarmoured cables
|
Technical
|
841036
|
AS/NZS 3012:2019 +A1 Electrical installations - Construction and demolition sites
|
2.5.6
|
CONSTRUCTION WIRING - Location and marking of overhead wiring (including aerial and catenary wiring)
|
Technical
|
841037
|
AS/NZS 3012:2019 +A1 Electrical installations - Construction and demolition sites
|
2.5.7
|
CONSTRUCTION WIRING - Type of aerial conductor
|
Technical
|
841038
|
AS/NZS 3012:2019 +A1 Electrical installations - Construction and demolition sites
|
2.5.8
|
CONSTRUCTION WIRING - Cables supported by a catenary
|
Technical
|
841039
|
AS/NZS 3012:2019 +A1 Electrical installations - Construction and demolition sites
|
2.6.1
|
FLEXIBLE CORDS, CORD EXTENSION SETS, FLEXIBLE CABLES AND ACCESSORIES - General
|
Technical
|
841040
|
AS/NZS 3012:2019 +A1 Electrical installations - Construction and demolition sites
|
2.6.2
|
FLEXIBLE CORDS, CORD EXTENSION SETS, FLEXIBLE CABLES AND ACCESSORIES - Minimum conductor size and core configuration
|
Technical
|
841041
|
AS/NZS 3012:2019 +A1 Electrical installations - Construction and demolition sites
|
2.6.3
|
FLEXIBLE CORDS, CORD EXTENSION SETS, FLEXIBLE CABLES AND ACCESSORIES - Type of flexible cord and cable
|
Technical
|
841042
|
AS/NZS 3012:2019 +A1 Electrical installations - Construction and demolition sites
|
2.6.4
|
FLEXIBLE CORDS, CORD EXTENSION SETS, FLEXIBLE CABLES AND ACCESSORIES - Colour
|
Technical
|
841043
|
AS/NZS 3012:2019 +A1 Electrical installations - Construction and demolition sites
|
2.6.5
|
FLEXIBLE CORDS, CORD EXTENSION SETS, FLEXIBLE CABLES AND ACCESSORIES - Current-carrying capacity
|
Technical
|
841044
|
AS/NZS 3012:2019 +A1 Electrical installations - Construction and demolition sites
|
2.6.6
|
FLEXIBLE CORDS, CORD EXTENSION SETS, FLEXIBLE CABLES AND ACCESSORIES - Accessories for connection
|
Technical
|
841045
|
AS/NZS 3012:2019 +A1 Electrical installations - Construction and demolition sites
|
2.6.7
|
FLEXIBLE CORDS, CORD EXTENSION SETS, FLEXIBLE CABLES AND ACCESSORIES - Maximum length
|
Technical
|
841046
|
AS/NZS 3012:2019 +A1 Electrical installations - Construction and demolition sites
|
2.6.8
|
FLEXIBLE CORDS, CORD EXTENSION SETS, FLEXIBLE CABLES AND ACCESSORIES - Limitations on the use of cord extension sets
|
Technical
|
841047
|
AS/NZS 3012:2019 +A1 Electrical installations - Construction and demolition sites
|
2.6.9
|
FLEXIBLE CORDS, CORD EXTENSION SETS, FLEXIBLE CABLES AND ACCESSORIES - Protection of flexible cords or cables
|
Technical
|
841048
|
AS/NZS 3012:2019 +A1 Electrical installations - Construction and demolition sites
|
2.6.10
|
FLEXIBLE CORDS, CORD EXTENSION SETS, FLEXIBLE CABLES AND ACCESSORIES - Portable socket-outlet assemblies (PSOAs)
|
Technical
|
841049
|
AS/NZS 3012:2019 +A1 Electrical installations - Construction and demolition sites
|
2.6.11
|
FLEXIBLE CORDS, CORD EXTENSION SETS, FLEXIBLE CABLES AND ACCESSORIES - Auxiliary socket-outlet panels
|
Technical
|
841050
|
AS/NZS 3012:2019 +A1 Electrical installations - Construction and demolition sites
|
2.6.12
|
FLEXIBLE CORDS, CORD EXTENSION SETS, FLEXIBLE CABLES AND ACCESSORIES - Electrical portable outlet devices (EPODS)
|
Technical
|
841051
|
AS/NZS 3012:2019 +A1 Electrical installations - Construction and demolition sites
|
2.7.2
|
LIGHTING AND LUMINAIRES - Mechanical protection
|
Technical
|
841052
|
AS/NZS 3012:2019 +A1 Electrical installations - Construction and demolition sites
|
2.7.3.1
|
LIGHTING AND LUMINAIRES - Emergency lighting - General
|
Technical
|
841053
|
AS/NZS 3012:2019 +A1 Electrical installations - Construction and demolition sites
|
2.7.3.2
|
LIGHTING AND LUMINAIRES - Verification
|
Technical
|
841054
|
AS/NZS 3012:2019 +A1 Electrical installations - Construction and demolition sites
|
2.7.4
|
LIGHTING AND LUMINAIRES - Hand-held luminaires
|
Technical
|
841055
|
AS/NZS 3012:2019 +A1 Electrical installations - Construction and demolition sites
|
2.7.5
|
LIGHTING AND LUMINAIRES - Edison screw type lampholders
|
Technical
|
841056
|
AS/NZS 3012:2019 +A1 Electrical installations - Construction and demolition sites
|
2.7.6
|
LIGHTING AND LUMINAIRES - Festoon lighting
|
Technical
|
841057
|
AS/NZS 3012:2019 +A1 Electrical installations - Construction and demolition sites
|
2.7.7
|
LIGHTING AND LUMINAIRES - Portable luminaires
|
Technical
|
841058
|
AS/NZS 3012:2019 +A1 Electrical installations - Construction and demolition sites
|
2.8.1
|
LIFT SHAFTS - General
|
Technical
|
841059
|
AS/NZS 3012:2019 +A1 Electrical installations - Construction and demolition sites
|
2.8.2
|
LIFT SHAFTS - Multiple lift shafts
|
Technical
|
841060
|
AS/NZS 3012:2019 +A1 Electrical installations - Construction and demolition sites
|
2.8.3
|
LIFT SHAFTS - Emergency lighting
|
Technical
|
841061
|
AS/NZS 3012:2019 +A1 Electrical installations - Construction and demolition sites
|
2.8.4
|
LIFT SHAFTS - False-car (Guided work platform)
|
Technical
|
841062
|
AS/NZS 3012:2019 +A1 Electrical installations - Construction and demolition sites
|
2.9
|
TRANSPORTABLE STRUCTURES
|
Technical
|
841063
|
AS/NZS 3012:2019 +A1 Electrical installations - Construction and demolition sites
|
3.2
|
FREQUENCY OF VERIFICATION (INSPECTION AND TESTING)
|
Technical
|
851001
|
AS 3011.1:2019 Secondary batteries installed in buildings Vented cells
|
2.1.1
|
Hydrogen emission
|
Technical
|
851002
|
AS 3011.1:2019 Secondary batteries installed in buildings Vented cells
|
2.1.2
|
Alarms
|
Technical
|
851003
|
AS 3011.1:2019 Secondary batteries installed in buildings Vented cells
|
2.1.3
|
Battery accommodation
|
Technical
|
851004
|
AS 3011.1:2019 Secondary batteries installed in buildings Vented cells
|
2.1.4
|
Arrangement of cells
|
Technical
|
851005
|
AS 3011.1:2019 Secondary batteries installed in buildings Vented cells
|
2.1.5
|
Ventilation
|
Technical
|
851006
|
AS 3011.1:2019 Secondary batteries installed in buildings Vented cells
|
2.2.1
|
BATTERY ROOM REQUIREMENTS - General
|
Technical
|
851007
|
AS 3011.1:2019 Secondary batteries installed in buildings Vented cells
|
2.2.2
|
Battery room layout and floor area
|
Technical
|
851008
|
AS 3011.1:2019 Secondary batteries installed in buildings Vented cells
|
2.2.3
|
Take-off battery terminals and outgoing busbars and cables
|
Technical
|
851009
|
AS 3011.1:2019 Secondary batteries installed in buildings Vented cells
|
2.2.4
|
Inter-tier and inter-row connections
|
Technical
|
851010
|
AS 3011.1:2019 Secondary batteries installed in buildings Vented cells
|
2.2.5
|
Inter-cell connectors
|
Technical
|
851011
|
AS 3011.1:2019 Secondary batteries installed in buildings Vented cells
|
2.2.6
|
Location of luminaires
|
Technical
|
851012
|
AS 3011.1:2019 Secondary batteries installed in buildings Vented cells
|
2.3.1
|
BATTERY ENCLOSURE REQUIREMENTS - Enclosure construction
|
Technical
|
851013
|
AS 3011.1:2019 Secondary batteries installed in buildings Vented cells
|
2.3.2
|
Take-off battery terminals and outgoing busbars and cables
|
Technical
|
851014
|
AS 3011.1:2019 Secondary batteries installed in buildings Vented cells
|
2.3.3
|
Battery compartment circuits
|
Technical
|
851015
|
AS 3011.1:2019 Secondary batteries installed in buildings Vented cells
|
3.1
|
INSTALLATION - GENERAL
|
Technical
|
851016
|
AS 3011.1:2019 Secondary batteries installed in buildings Vented cells
|
3.2
|
CONNECTIONS
|
Technical
|
851017
|
AS 3011.1:2019 Secondary batteries installed in buildings Vented cells
|
3.3.1
|
Overcurrent protection
|
Technical
|
851018
|
AS 3011.1:2019 Secondary batteries installed in buildings Vented cells
|
3.3.2
|
Warning notices
|
Technical
|
851019
|
AS 3011.1:2019 Secondary batteries installed in buildings Vented cells
|
3.3.3
|
Switchgear
|
Technical
|
851020
|
AS 3011.1:2019 Secondary batteries installed in buildings Vented cells
|
3.3.4
|
Earth-leakage detection
|
Technical
|
851021
|
AS 3011.1:2019 Secondary batteries installed in buildings Vented cells
|
3.3.5
|
Main isolating switch
|
Technical
|
851022
|
AS 3011.1:2019 Secondary batteries installed in buildings Vented cells
|
3.3.6
|
Section isolating equipment
|
Technical
|
851023
|
AS 3011.1:2019 Secondary batteries installed in buildings Vented cells
|
3.3.7
|
Fire safety and warning signs
|
Technical
|
861001
|
AS 3011.2:2019 Secondary batteries installed in buildings Sealed cells
|
2.1.1
|
Hydrogen emission
|
Technical
|
861002
|
AS 3011.2:2019 Secondary batteries installed in buildings Sealed cells
|
2.1.2
|
Alarms
|
Technical
|
861003
|
AS 3011.2:2019 Secondary batteries installed in buildings Sealed cells
|
2.1.3
|
Battery accommodation
|
Technical
|
861004
|
AS 3011.2:2019 Secondary batteries installed in buildings Sealed cells
|
2.1.4
|
Arrangement of cells
|
Technical
|
861005
|
AS 3011.2:2019 Secondary batteries installed in buildings Sealed cells
|
2.1.5
|
Ventilation
|
Technical
|
861006
|
AS 3011.2:2019 Secondary batteries installed in buildings Sealed cells
|
2.2.1
|
BATTERY ROOM REQUIREMENTS - General
|
Technical
|
861007
|
AS 3011.2:2019 Secondary batteries installed in buildings Sealed cells
|
2.2.2
|
Battery room layout and floor area
|
Technical
|
861008
|
AS 3011.2:2019 Secondary batteries installed in buildings Sealed cells
|
2.2.3
|
Take-off battery terminals and outgoing busbars and cables
|
Technical
|
861009
|
AS 3011.2:2019 Secondary batteries installed in buildings Sealed cells
|
2.2.4
|
Inter-tier and inter-row connections
|
Technical
|
861010
|
AS 3011.2:2019 Secondary batteries installed in buildings Sealed cells
|
2.2.5
|
Inter-cell connectors
|
Technical
|
861011
|
AS 3011.2:2019 Secondary batteries installed in buildings Sealed cells
|
2.2.6
|
Luminaires
|
Technical
|
861012
|
AS 3011.2:2019 Secondary batteries installed in buildings Sealed cells
|
2.3.1
|
BATTERY ENCLOSURE REQUIREMENTS - Enclosure construction
|
Technical
|
861013
|
AS 3011.2:2019 Secondary batteries installed in buildings Sealed cells
|
2.3.2
|
Take-off battery terminals and outgoing busbars and cables
|
Technical
|
861014
|
AS 3011.2:2019 Secondary batteries installed in buildings Sealed cells
|
2.3.3
|
Battery compartment circuits
|
Technical
|
861015
|
AS 3011.2:2019 Secondary batteries installed in buildings Sealed cells
|
3.1
|
INSTALLATION - GENERAL
|
Technical
|
861016
|
AS 3011.2:2019 Secondary batteries installed in buildings Sealed cells
|
3.2
|
CONNECTIONS
|
Technical
|
861017
|
AS 3011.2:2019 Secondary batteries installed in buildings Sealed cells
|
3.3.1
|
Overcurrent protection
|
Technical
|
861018
|
AS 3011.2:2019 Secondary batteries installed in buildings Sealed cells
|
3.3.2
|
Warning notices
|
Technical
|
861019
|
AS 3011.2:2019 Secondary batteries installed in buildings Sealed cells
|
3.3.3
|
Switchgear
|
Technical
|
861020
|
AS 3011.2:2019 Secondary batteries installed in buildings Sealed cells
|
3.3.4
|
Earth-leakage detection
|
Technical
|
861021
|
AS 3011.2:2019 Secondary batteries installed in buildings Sealed cells
|
3.3.5
|
Main isolating switch
|
Technical
|
861022
|
AS 3011.2:2019 Secondary batteries installed in buildings Sealed cells
|
3.3.6
|
Section isolating equipment
|
Technical
|
861023
|
AS 3011.2:2019 Secondary batteries installed in buildings Sealed cells
|
3.3.7
|
Fire safety and warning signs
|
Technical
|
311001
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
2.1
|
GENERAL
|
Technical
|
311002
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
2.2
|
CLASSIFICATION OF PATIENT AREAS
|
Technical
|
311003
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
2.2.1
|
Documentation
|
Technical
|
311004
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
2.2.2
|
Patient area boundaries
|
Technical
|
311005
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
2.2.3
|
Patient areas required to be wired as cardiac-protected electrical areas
|
Technical
|
311006
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
2.2.4
|
Patient areas required to be wired as body-protected electrical areas
|
Technical
|
311007
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
2.3
|
SUPPLY OF ELECTRICITY TO PATIENT AREAS
|
Technical
|
311008
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
2.4
|
LOW-VOLTAGE A.C. SUPPLIES
|
Technical
|
311009
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
2.4.1
|
Separation of circuits
|
Technical
|
311010
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
2.4.1.1
|
Body-protected electrical areas
|
Technical
|
311011
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
2.4.1.2
|
Cardiac-protected electrical areas
|
Technical
|
311012
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
2.4.1.3
|
Body-protected and cardiac-protected electrical areas
|
Technical
|
311013
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
2.4.2
|
Protection of wiring systems and electrical equipment against mechanical damage
|
Technical
|
311014
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
2.4.3
|
Leakage protective device protection required
|
Technical
|
311015
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
2.4.3.1
|
General
|
Technical
|
311016
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
2.4.3.1.1
|
Electrical points
|
Technical
|
311017
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
2.4.3.1.2
|
Extra-low-voltage (ELV) charging sockets-outlets
|
Technical
|
311018
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
2.4.3.2
|
Socket-outlets requiring LPD protection
|
Technical
|
311019
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
2.4.3.2.1
|
General
|
Technical
|
312020
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
2.4.3.2.2
|
Locations of socket-outlets requiring LPD protection
|
Unsafe
|
312021
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
2.4.3.2.3
|
Types of socket-outlets requiring LPD protection
|
Unsafe
|
312022
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
2.4.3.3
|
Permanently-wired medical electrical equipment requiring LPD protection
|
Unsafe
|
311023
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
2.4.4
|
Low-voltage uninterruptible supplies (UPS)
|
Technical
|
311024
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
2.4.4.1
|
General
|
Technical
|
312025
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
2.4.4.2
|
Leakage protective device protection of uninterruptible supplies (UPS)
|
Unsafe
|
311026
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
2.4.4.3
|
Uninterruptable power supply status indicators
|
Technical
|
311027
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
2.5
|
LOW-VOLTAGE D.C. SUPPLIES
|
Technical
|
311028
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
2.6
|
ACCESS TO CONTROLS AND INDICATORS
|
Technical
|
311029
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
2.7
|
SOCKET-OUTLETS
|
Technical
|
312030
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
2.7.1
|
Number of socket-outlets
|
Unsafe
|
311031
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
2.7.2
|
Socket-outlets requiring isolating switches
|
Technical
|
311032
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
2.7.3
|
Socket-outlets for cleaning equipment
|
Technical
|
311033
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
2.7.3.1
|
Location of socket-outlets identified ?CLEANING PURPOSES ONLY?
|
Technical
|
312034
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
2.7.3.2
|
Protection of socket-outlets identified ?CLEANING PURPOSES ONLY?
|
Unsafe
|
311035
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
2.7.4
|
Identification of socket-outlets
|
Technical
|
311036
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
2.7.4.1
|
Identification of socket-outlets protected by LPDs
|
Technical
|
311037
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
2.7.4.2
|
Switch indication
|
Technical
|
311038
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
2.7.4.3
|
Colour coding
|
Technical
|
311039
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
2.7.4.3.1
|
Low voltage (LV) socket-outlets
|
Technical
|
311040
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
2.7.4.3.2
|
Extra-low-voltage (ELV) socket-outlets
|
Technical
|
311041
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
2.7.4.4
|
Power available indication for RCD-protected socket-outlets
|
Technical
|
312042
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
2.7.5
|
Socket-outlet switches
|
Unsafe
|
311043
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
2.8
|
RESIDUAL CURRENT DEVICES (RCDs)
|
Technical
|
312044
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
2.8.1
|
Type of RCD
|
Unsafe
|
311045
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
2.8.2
|
Discrimination
|
Technical
|
311046
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
2.8.3
|
Number and disposition of electrical points controlled by RCDs
|
Technical
|
311047
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
2.8.4
|
Indication
|
Technical
|
311048
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
2.8.5
|
Identification of RCDs
|
Technical
|
311049
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
2.8.6
|
Permanently wired equipment
|
Technical
|
311050
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
2.8.7
|
Test facility
|
Technical
|
311051
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
2.8.8
|
Location of RCDs
|
Technical
|
311052
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
2.9
|
LOW-VOLTAGE ISOLATED SUPPLIES
|
Technical
|
312053
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
2.9.1
|
General
|
Unsafe
|
312054
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
2.9.2
|
Isolation transformers
|
Unsafe
|
311055
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
2.9.3
|
Overcurrent circuit-breaker
|
Technical
|
311056
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
2.9.4
|
Overload monitor
|
Technical
|
311057
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
2.9.5
|
Line isolation monitor
|
Technical
|
311058
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
2.9.5.1
|
General
|
Technical
|
311059
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
2.9.5.2
|
Identification of LIMs
|
Technical
|
311060
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
2.9.6
|
System prospective hazard current
|
Technical
|
311061
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
2.9.7
|
Number and disposition of electrical points protected by an isolated supply
|
Technical
|
311062
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
2.9.8
|
Permanently wired equipment
|
Technical
|
311063
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
2.9.9
|
Test facility
|
Technical
|
311064
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
2.1
|
ISOLATION SWITCHES
|
Technical
|
311065
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
2.11
|
EXTRA-LOW-VOLTAGE (ELV) SUPPLIES
|
Technical
|
311066
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
2.11.1
|
General
|
Technical
|
311067
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
2.11.2
|
Source of ELV supply
|
Technical
|
311068
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
2.12
|
IDENTIFICATION
|
Technical
|
311069
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
2.12.1
|
General
|
Technical
|
311070
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
2.12.2
|
Identification of patient areas
|
Technical
|
313071
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
2.13
|
TESTING AND VERIFICATION OF ELECTRICAL WORK
|
Testing
|
313072
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
2.14
|
ADDITIONAL DOCUMENTATION
|
Testing
|
311073
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
3.1
|
GENERAL
|
Technical
|
311074
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
3.2
|
EARTHING
|
Technical
|
311075
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
4.1
|
GENERAL
|
Technical
|
312076
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
4.2
|
EARTH-FREE ELV
|
Unsafe
|
311077
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
4.3
|
DISPOSITION OF ELECTRICAL POINTS CONTROLLED BY LPDs
|
Technical
|
311078
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
4.4
|
EARTHING AND EQUIPOTENTIAL BONDING
|
Technical
|
312079
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
4.4.1
|
General
|
Unsafe
|
311080
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
4.4.2
|
Equipotential earthing system
|
Technical
|
311081
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
4.4.2.1
|
General
|
Technical
|
311082
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
4.4.2.2
|
Provision of equipotential earthing system
|
Technical
|
311083
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
4.4.2.3
|
Form of equipotential earthing system
|
Technical
|
311084
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
4.4.2.4
|
Earthing of socket-outlets
|
Technical
|
312085
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
4.4.2.4.1
|
General
|
Unsafe
|
311086
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
4.4.2.4.2
|
Protective earthing conductor
|
Technical
|
312087
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
4.4.2.5
|
Earthing of permanently installed electrical equipment
|
Unsafe
|
311088
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
4.4.2.5.1
|
Points required to be earthed via the EP junction or node
|
Technical
|
311089
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
4.4.2.5.2
|
Method of connecting the earthing conductor to the equipment
|
Technical
|
311090
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
4.4.2.5.3
|
Method of connecting the earthing conductor to the EP junction or node
|
Technical
|
311091
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
4.4.2.5.4
|
Insulation and segregation of earthing conductors
|
Technical
|
311092
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
4.4.2.5.5
|
Maximum resistance of earthing conductors
|
Technical
|
311093
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
4.4.2.6
|
Equipotential earthing of non-electrical equipment and fittings
|
Technical
|
311094
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
4.4.2.7
|
Earthing connections
|
Technical
|
311095
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
4.4.2.8
|
Equipotential (EP) junction
|
Technical
|
311096
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
4.4.2.9
|
Equipotential (EP) test facility
|
Technical
|
311097
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
4.4.2.10
|
Equipotential (EP) test terminal
|
Technical
|
311098
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
4.4.3
|
Return earths
|
Technical
|
311099
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
5.1
|
GENERAL
|
Technical
|
311100
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
5.2
|
HOMECARE INSTALLATIONS
|
Technical
|
311101
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
5.2.1
|
Conformance with AS/NZS 3000
|
Technical
|
311102
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
5.2.2
|
Conformance with this Standard AUS
|
Technical
|
312103
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
5.2.2.1
|
Leakage protective device (LPD) protection
|
Unsafe
|
312104
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
5.2.2.2
|
Socket-outlets
|
Unsafe
|
311105
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
5.2.2.3
|
Circuit protection and identification
|
Technical
|
311106
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
5.2.3
|
Conformance with this Standard NZ
|
Technical
|
312107
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
5.2.3.1
|
Leakage protective device (LPD) protection
|
Unsafe
|
312108
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
5.2.3.2
|
Socket-outlets
|
Unsafe
|
311109
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
5.2.3.3
|
Circuit protection and identification
|
Technical
|
311110
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
5.3
|
DISABILITY AND AGED CARE INSTALLATIONS
|
Technical
|
311111
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
5.4
|
INSTALLATIONS FOR SELF-HARM PATIENTS
|
Technical
|
311112
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
5.4.1
|
General
|
Technical
|
311113
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
5.4.2
|
Identification
|
Technical
|
311114
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
6.1
|
INTRODUCTION
|
Technical
|
311115
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
6.2
|
ALTERATIONS
|
Technical
|
311116
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
6.2.1
|
General
|
Technical
|
311117
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
6.2.2
|
Patient areas not signposted as cardiac-protected or body-protected electrical areas
|
Technical
|
312118
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
6.2.3
|
Patient areas signposted as cardiac-protected or body-protected electrical areas
|
Technical
|
311119
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
6.2.4
|
Installation of new socket-outlets in patient areas wired as either body-protected or cardiac-protected
|
Technical
|
311120
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
6.2.5
|
Alterations to electrical installations in patient areas
|
Technical
|
311121
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
6.2.5.1
|
Alterations in cardiac-protected electrical areas
|
Technical
|
311122
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
6.2.5.2
|
Fixed electrical equipment rated at or above 2.0 kW
|
Technical
|
311123
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
6.2.5.3
|
Reclassification of existing cardiac-protected electrical areas as body-protected electrical areas.
|
Technical
|
311124
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
6.3
|
REPAIRS
|
Technical
|
311125
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
6.3.1
|
Patient areas not wired as cardiac-protected or body-protected electrical areas
|
Technical
|
311126
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
6.3.2
|
Patient areas wired as cardiac-protected or body-protected electrical areas AUS
|
Technical
|
311127
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
6.4
|
IDENTIFICATION
|
Technical
|
311128
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
7.1
|
GENERAL
|
Technical
|
311129
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
7.2
|
BODY-PROTECTED ELECTRICAL AREA SIGN
|
Technical
|
311130
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
7.3
|
CARDIAC-PROTECTED ELECTRICAL AREA SIGN
|
Technical
|
311131
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
8.1
|
GENERAL
|
Technical
|
311132
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
8.2
|
BODY-PROTECTED ELECTRICAL AREAS
|
Technical
|
311133
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
8.2.1
|
General
|
Technical
|
311134
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
8.2.1.1
|
Inspection
|
Technical
|
311135
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
8.2.1.2
|
Labelling
|
Technical
|
311136
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
8.2.1.3
|
Socket-outlets
|
Technical
|
311137
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
8.2.1.3.1
|
Colour coding
|
Technical
|
311138
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
8.2.1.3.2
|
Power-available lights
|
Technical
|
311139
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
8.2.1.3.3
|
Maximum number of socket-outlets per LPD
|
Technical
|
311140
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
8.2.1.3.4
|
Power ?ON? indicators
|
Technical
|
311141
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
8.2.1.4
|
Switches
|
Technical
|
311142
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
8.2.1.5
|
Wiring
|
Technical
|
311143
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
8.2.2
|
Earthing
|
Technical
|
313145
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
8.2.3.1
|
General
|
Testing
|
313146
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
8.2.3.2
|
Sensitivity test
|
Testing
|
313147
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
8.2.3.3
|
Maximum tripping time tests AUS
|
Testing
|
311148
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
8.2.3.4
|
Maximum tripping time tests NZ
|
Technical
|
311149
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
8.2.3.5
|
Residual current device (RCD) power-available indicator lights
|
Technical
|
313150
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
8.2.3.6
|
Audible and visible RCD trip indicators
|
Testing
|
311151
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
8.2.4
|
Line isolation monitors (LIMs)
|
Technical
|
313152
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
8.2.4.1
|
Prospective hazard current of the installation
|
Testing
|
313153
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
8.2.4.2
|
Prospective hazard current alarm
|
Testing
|
313154
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
8.2.5
|
Overload monitors
|
Testing
|
311155
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
8.2.6
|
Uninterruptible power supplies (UPSs)
|
Technical
|
311156
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
8.2.7
|
Documentation
|
Technical
|
311157
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
8.3
|
CARDIAC-PROTECTED ELECTRICAL AREAS
|
Technical
|
311158
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
8.3.1
|
General
|
Technical
|
311159
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
8.3.1.1
|
Inspection
|
Technical
|
311160
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
8.3.1.2
|
Labelling
|
Technical
|
311161
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
8.3.1.3
|
Socket-outlets
|
Technical
|
311162
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
8.3.1.3.1
|
Colour coding
|
Technical
|
311163
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
8.3.1.3.2
|
Power-available lights
|
Technical
|
311164
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
8.3.1.3.3
|
Maximum number of socket-outlets per LPD
|
Technical
|
311165
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
8.3.1.3.4
|
Power ?ON? indicators
|
Technical
|
311166
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
8.3.1.3.5
|
Switches
|
Technical
|
311167
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
8.3.1.3.6
|
Wiring
|
Technical
|
311168
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
8.3.1.3.7
|
Disposition of socket-outlets protected by RCDs
|
Technical
|
311169
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
8.3.2
|
Earthing
|
Technical
|
313170
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
8.3.2.1
|
Inspection
|
Testing
|
313171
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
8.3.2.2
|
Testing
|
Testing
|
311172
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
8.3.3
|
Residual current devices (RCDs)
|
Technical
|
313173
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
8.3.3.1
|
General
|
Testing
|
313174
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
8.3.3.2
|
Sensitivity test
|
Testing
|
313175
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
8.3.3.3
|
Maximum tripping time tests
|
Testing
|
313176
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
8.3.3.4
|
Maximum tripping time tests
|
Testing
|
311177
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
8.3.3.5
|
RCD power-available indicator lights
|
Technical
|
311178
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
8.3.3.6
|
Audiovisual RCD trip indicators
|
Technical
|
311179
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
8.3.4
|
Line isolation monitors (LIMs)
|
Technical
|
313180
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
8.3.4.1
|
Prospective hazard current of the installation
|
Testing
|
313181
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
8.3.4.2
|
Prospective hazard current alarm
|
Testing
|
313182
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
8.3.5
|
Overload monitors
|
Testing
|
311183
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
8.3.6
|
Uninterruptible power supplies (UPS)
|
Technical
|
311184
|
AS/NZS 3003:2018 +A1 Electrical installations - Patient areas
|
8.3.7
|
Documentation
|
Technical
|
411001
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
2.1.1
|
General requirements
|
Technical
|
411002
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
2.1.2
|
Agreements between supplier (manufacturer) and user
|
Technical
|
411005
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
2.2.2
|
Voltage classification
|
Technical
|
411006
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
2.2.3
|
Current in normal operation
|
Technical
|
411007
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
2.2.4
|
Short-circuit current
|
Technical
|
411008
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
2.2.4.1
|
Mechanical and thermal effects
|
Technical
|
411009
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
2.2.4.2
|
Types
|
Technical
|
411013
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
2.2.5
|
Rated frequency
|
Technical
|
411014
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
2.2.6
|
Corona
|
Technical
|
411015
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
2.2.6.1
|
General
|
Technical
|
411016
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
2.2.6.2
|
Radio and television interference
|
Technical
|
411017
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
2.2.6.3
|
Audible noise
|
Technical
|
411018
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
2.2.7
|
High voltage design practices with respect to EMF
|
Technical
|
411019
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
2.2.8
|
Overvoltages
|
Technical
|
411022
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
2.3.1
|
CIVIL AND STRUCTURAL REQUIREMENTS - General
|
Technical
|
411023
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
2.3.2
|
Equipment and structures
|
Technical
|
411024
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
2.3.2.1
|
General
|
Technical
|
411025
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
2.3.2.2
|
Permanent loads (G)
|
Technical
|
411026
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
2.3.2.3
|
Imposed and other loads (Q, W, E)
|
Technical
|
411027
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
2.3.2.4
|
Special loads
|
Technical
|
411028
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
2.3.3
|
Coincident temperatures
|
Technical
|
411030
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
2.3.5
|
Load combinations
|
Technical
|
411031
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
2.3.6
|
Deflections and serviceability limits
|
Technical
|
411032
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
2.4
|
CLIMATIC AND ENVIRONMENTAL CONDITIONS
|
Technical
|
411033
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
2.4.1
|
General
|
Technical
|
411034
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
2.4.2
|
Normal conditions
|
Technical
|
411035
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
2.4.2.1
|
Indoor
|
Technical
|
411036
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
2.4.2.2
|
Outdoor
|
Technical
|
411037
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
2.4.3
|
Special conditions
|
Technical
|
411038
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
2.4.3.1
|
General
|
Technical
|
411039
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
2.4.3.2
|
Altitude
|
Technical
|
411040
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
2.4.3.3
|
Pollution
|
Technical
|
411041
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
2.4.3.4
|
Temperature and humidity
|
Technical
|
411042
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
2.4.3.5
|
Vibration
|
Technical
|
411043
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
2.4.3.6
|
Seismic vibration
|
Technical
|
411044
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
2.4.3.7
|
The effect of wind
|
Technical
|
411045
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
2.5
|
SPECIAL REQUIREMENTS
|
Technical
|
411046
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
2.5.1
|
Effects of small animals and micro-organisms
|
Technical
|
411047
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
2.5.2
|
Noise level
|
Technical
|
411051
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
3.1
|
GENERAL
|
Technical
|
411052
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
3.2
|
SELECTION OF INSULATION LEVEL
|
Technical
|
411053
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
3.2.1
|
General
|
Technical
|
411055
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
3.2.3
|
Consideration of rated withstand voltages
|
Technical
|
411056
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
3.3
|
VERIFICATION OF WITHSTAND VALUES
|
Technical
|
411057
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
3.4
|
MINIMUM CLEARANCES OF LIVE PARTS
|
Technical
|
411058
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
3.4.1
|
General
|
Technical
|
411059
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
3.4.2
|
Minimum clearances in voltage range I
|
Technical
|
411061
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
3.5
|
MINIMUM CLEARANCES BETWEEN PARTS UNDER SPECIAL CONDITIONS
|
Technical
|
411062
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
3.6
|
TYPE TESTED EQUIPMENT
|
Technical
|
411063
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
4.1
|
GENERAL REQUIREMENTS
|
Technical
|
411064
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
4.1.1
|
Selection
|
Technical
|
411065
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
4.1.2
|
Equipment Safety
|
Technical
|
412066
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
4.1.3
|
Personnel safety
|
Unsafe
|
411067
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
4.1.4
|
Labels
|
Technical
|
411068
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
4.2
|
SPECIFIC REQUIREMENTS
|
Technical
|
411069
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
4.2.1
|
Switching devices
|
Technical
|
411070
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
4.2.2
|
Power transformers and reactors
|
Technical
|
411071
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
4.2.3
|
Gas-insulated metal-enclosed equipment (GIE), metal-enclosed switchgear, insulation-enclosed switchgear and other prefab ricated type-tested switchgear and fusegear assemblies
|
Technical
|
411072
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
4.2.4
|
Instrument transformers
|
Technical
|
411073
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
4.2.4.1
|
General
|
Technical
|
411074
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
4.2.4.2
|
Current transformers
|
Technical
|
411075
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
4.2.4.3
|
Voltage transformers
|
Technical
|
411076
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
4.2.5
|
Surge arresters
|
Technical
|
411077
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
4.2.6
|
Capacitors
|
Technical
|
411079
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
4.2.8
|
Insulators
|
Technical
|
411080
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
4.2.9
|
Insulated cables other than for overhead lines
|
Technical
|
411081
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
4.2.9.1
|
General requirements
|
Technical
|
411082
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
4.2.9.2
|
Temperature
|
Technical
|
411083
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
4.2.9.3
|
Stress due to temperature changes
|
Technical
|
411084
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
4.2.9.4
|
Flexible reeling and trailing cables
|
Technical
|
411085
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
4.2.9.5
|
Crossings and proximities
|
Technical
|
411086
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
4.2.9.6
|
Installation of cables
|
Technical
|
411087
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
4.2.9.7
|
Bending radius
|
Technical
|
411088
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
4.2.9.8
|
Tensile stress
|
Technical
|
411089
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
4.2.10
|
Conductors and accessories
|
Technical
|
411090
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
4.2.11
|
Rotating electrical machines
|
Technical
|
411091
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
4.2.12
|
Generating units
|
Technical
|
411092
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
4.2.13
|
Generating unit main connections
|
Technical
|
411093
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
4.2.14
|
Static converters
|
Technical
|
411094
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
4.2.15
|
Fuses
|
Technical
|
411095
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
4.2.15.1
|
Clearances
|
Technical
|
411096
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
4.2.15.2
|
Fuse replacement
|
Technical
|
411097
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
4.2.16
|
Electrical and mechanical interlocking
|
Technical
|
411099
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
5.1.1
|
MINIMUM REQUIREMENTS - General
|
Technical
|
411100
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
5.1.2
|
Circuit arrangement
|
Technical
|
411101
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
5.1.2.1
|
Design
|
Technical
|
411102
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
5.1.2.2
|
Protective measures
|
Technical
|
411103
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
5.1.3
|
Documentation
|
Technical
|
411104
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
5.1.4
|
Transport routes
|
Technical
|
411105
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
5.1.5
|
Aisles and access areas
|
Technical
|
411106
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
5.1.6
|
Lighting
|
Technical
|
411107
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
5.1.7
|
Operational safety
|
Technical
|
411108
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
5.1.8
|
Labelling
|
Technical
|
411109
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
5.2
|
OUTDOOR INSTALLATIONS OF OPEN DESIGN
|
Technical
|
411110
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
5.2.1
|
General
|
Technical
|
412111
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
5.2.2
|
Protective barrier clearances
|
Unsafe
|
412112
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
5.2.3
|
Protective obstacle clearances
|
Unsafe
|
412113
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
5.2.4
|
Boundary clearances
|
Technical
|
411114
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
5.2.5
|
Minimum height over access area
|
Technical
|
411115
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
5.2.6
|
Minimum clearances for maintenance
|
Technical
|
411116
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
5.2.7
|
Clearances to buildings within closed electrical operating areas
|
Technical
|
411117
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
5.2.8
|
External fences or walls and access doors
|
Technical
|
411118
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
5.3
|
INDOOR INSTALLATIONS OF OPEN DESIGN
|
Technical
|
411119
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
5.4
|
INSTALLATION OF PREFABRICATED TYPE-TESTED SWITCHGEAR
|
Technical
|
411120
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
5.4.1
|
General
|
Technical
|
411121
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
5.4.2
|
Additional requirements for gas-insulated metal enclosed equipment (GIE)
|
Technical
|
411122
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
5.4.2.1
|
Design
|
Technical
|
411123
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
5.4.2.2
|
Erection on site
|
Technical
|
411125
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
5.4.2.4
|
Earthing
|
Technical
|
411126
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
5.5
|
REQUIREMENTS FOR BUILDINGS
|
Technical
|
411127
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
5.5.1
|
Introduction
|
Technical
|
411128
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
5.5.2
|
Structural provisions
|
Technical
|
411129
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
5.5.2.1
|
General
|
Technical
|
411130
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
5.5.2.2
|
Specifications for walls
|
Technical
|
411131
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
5.5.2.3
|
Windows
|
Technical
|
411132
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
5.5.2.4
|
Roofs
|
Technical
|
411133
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
5.5.2.5
|
Floors
|
Technical
|
411134
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
5.5.3
|
Rooms for switchgear
|
Technical
|
411135
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
5.5.4
|
Service areas
|
Technical
|
411136
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
5.5.5
|
Doors
|
Technical
|
411137
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
5.5.6
|
Draining of insulating liquids
|
Technical
|
411138
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
5.5.7
|
Heating, ventilation and cooling
|
Technical
|
411139
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
5.5.7.1
|
General
|
Technical
|
411140
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
5.5.7.2
|
Ventilation of battery rooms
|
Technical
|
411141
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
5.5.7.3
|
Rooms for emergency generating units
|
Technical
|
411142
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
5.5.8
|
Buildings that require special consideration
|
Technical
|
411143
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
5.5.9
|
Confined spaces
|
Technical
|
411144
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
5.6
|
HIGH VOLTAGE/LOW VOLTAGE PREFABRICATED SUBSTATIONS
|
Technical
|
411145
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
5.7
|
ELECTRICAL INSTALLATIONS ON A MAST, POLE OR TOWER
|
Technical
|
411146
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
6.1
|
GENERAL
|
Technical
|
412147
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
6.2.1
|
PROTECTION AGAINST DIRECT CONTACT - General
|
Unsafe
|
411149
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
6.2.2
|
Measures for protection against direct contact
|
Technical
|
411150
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
6.2.2.1
|
Recognized protection types
|
Technical
|
411151
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
6.2.2.2
|
Design of protective measures
|
Technical
|
411152
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
6.2.3
|
Protection requirements
|
Technical
|
411153
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
6.2.3.1
|
Protection outside of closed electrical operating areas
|
Technical
|
411154
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
6.2.3.2
|
Protection inside closed electrical operating areas
|
Technical
|
411155
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
6.2.3.3
|
Protection during normal operation
|
Technical
|
411157
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
6.4
|
MEANS TO PROTECT PERSONS WORKING ON OR NEAR ELECTRICAL INSTALLATIONS
|
Technical
|
411158
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
6.4.1
|
Construction and working procedures
|
Technical
|
411159
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
6.4.2
|
Equipment for isolating installations or apparatus
|
Technical
|
411160
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
6.4.3
|
Devices to prevent inadvertent closing of isolating devices
|
Technical
|
411161
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
6.4.4
|
Devices for determining the de-energized state
|
Technical
|
411162
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
6.4.5
|
Devices for earthing and short-circuiting
|
Technical
|
411163
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
6.4.6
|
Equipment acting as protective barriers against adjacent live parts
|
Technical
|
411164
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
6.4.6.1
|
General
|
Technical
|
411165
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
6.4.6.2
|
Insertable insulated partitions
|
Technical
|
411166
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
6.4.6.3
|
Insertable partition walls
|
Technical
|
411167
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
6.4.7
|
Storage of personal protection equipment
|
Technical
|
411168
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
6.5
|
PROTECTION FROM DANGER RESULTING FROM ARC FAULT
|
Technical
|
411169
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
6.6
|
PROTECTION AGAINST DIRECT LIGHTNING STRIKES
|
Technical
|
411170
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
6.7
|
PROTECTION AGAINST FIRE AND EXPLOSION
|
Technical
|
411171
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
6.7.1
|
Risk
|
Technical
|
411172
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
6.7.1.1
|
General
|
Technical
|
411173
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
6.7.1.2
|
Fire and explosion risk zones
|
Technical
|
411174
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
6.7.1.3
|
Fire and explosion sources risk assessment
|
Technical
|
411175
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
6.7.1.4
|
Fire and explosion risk management
|
Technical
|
411176
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
6.7.1.5
|
Fire resistant barriers
|
Technical
|
411177
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
6.7.1.6
|
Protection of personnel within high voltage installations
|
Technical
|
411178
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
6.7.2
|
Buildings
|
Technical
|
411179
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
6.7.2.1
|
General
|
Technical
|
411180
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
6.7.2.2
|
Fire alarm systems
|
Technical
|
411181
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
6.7.2.3
|
Fire suppression systems
|
Technical
|
411182
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
6.7.3
|
Plant and equipment requirements
|
Technical
|
411183
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
6.7.4
|
Transformers, reactors
|
Technical
|
411184
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
6.7.4.1
|
General
|
Technical
|
411185
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
6.7.4.2
|
Fire mitigation options for transformers
|
Technical
|
411186
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
6.7.4.3
|
Transformer fire damage control measures
|
Technical
|
411187
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
6.7.4.4
|
Outdoor transformers
|
Technical
|
411188
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
6.7.4.5
|
Indoor transformers
|
Technical
|
411189
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
6.7.5
|
Cables
|
Technical
|
411190
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
6.7.6
|
Distribution substations
|
Technical
|
411191
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
6.7.6.1
|
Special requirements for distribution kiosk/padmount cubicles and walled high voltage installations
|
Technical
|
411192
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
6.7.6.2
|
Special requirements for distribution indoor high voltage installations
|
Technical
|
411193
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
6.8
|
PROTECTION AGAINST LEAKAGE OF INSULATING LIQUIDS AND SF6
|
Technical
|
411194
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
6.8.1
|
Oil containment
|
Technical
|
411195
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
6.8.2
|
SF6 leakage
|
Technical
|
411197
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
6.8.4
|
Fire protected high voltage installation examples for distribution substations
|
Technical
|
411198
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
6.9
|
IDENTIFICATION AND MARKING
|
Technical
|
411199
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
6.9.1
|
General
|
Technical
|
411200
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
6.9.2
|
Information plates and warning plates
|
Technical
|
411201
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
6.9.3
|
Electrical hazard warning
|
Technical
|
411202
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
6.9.4
|
Installations with incorporated capacitors
|
Technical
|
411203
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
6.9.5
|
Emergency signs for emergency exits
|
Technical
|
411204
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
6.9.6
|
Cable identification marks
|
Technical
|
411205
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
6.1
|
PROTECTION AGAINST UNAUTHORIZED ACCESS
|
Technical
|
411206
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
7.1
|
PROTECTION SYSTEMS
|
Technical
|
411207
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
7.2
|
MONITORING AND CONTROL SYSTEMS
|
Technical
|
411208
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
7.3
|
A.C. AND D.C. SUPPLY CIRCUITS
|
Technical
|
411209
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
7.3.1
|
General
|
Technical
|
411210
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
7.3.2
|
a.c. supply
|
Technical
|
411211
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
7.3.3
|
d.c. supply
|
Technical
|
411212
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
7.3.3.1
|
Capacity
|
Technical
|
411213
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
7.3.3.2
|
Monitoring voltage and current
|
Technical
|
411214
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
7.3.3.3
|
Sizing and selection of batteries
|
Technical
|
411215
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
7.3.3.4
|
Battery rooms and cubicles
|
Technical
|
411216
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
7.3.3.5
|
Protection against corrosion
|
Technical
|
411217
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
7.4
|
COMPRESSED AIR SYSTEMS
|
Technical
|
411218
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
7.4.1
|
Design
|
Technical
|
411219
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
7.4.2
|
Relative humidity
|
Technical
|
411220
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
7.4.3
|
Operating capacity
|
Technical
|
411221
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
7.4.4
|
Protection against corrosion
|
Technical
|
411222
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
7.4.5
|
Marking
|
Technical
|
411223
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
7.4.6
|
Isolation and drainage
|
Technical
|
411224
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
7.4.7
|
Arcing
|
Technical
|
411225
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
7.4.8
|
Accessible controls
|
Technical
|
411226
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
7.5
|
SF6 GAS HANDLING PLANT
|
Technical
|
411229
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
7.6.2
|
Electrical noise sources in high voltage installations
|
Technical
|
411230
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
7.6.3
|
Measures to be taken to reduce the effects of high frequency interference
|
Technical
|
411231
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
7.6.4
|
Measures to be taken to reduce the effects of low frequency interference
|
Technical
|
411232
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
7.6.5
|
Measures related to the selection of equipment
|
Technical
|
411233
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
7.6.5.1
|
Zones
|
Technical
|
411234
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
7.6.5.2
|
Internal circuitry
|
Technical
|
411235
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
7.6.5.3
|
Gas-insulated switchgear
|
Technical
|
411236
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
7.6.6
|
Other possible measures to reduce the effects of interference
|
Technical
|
411237
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
8.1
|
GENERAL
|
Technical
|
411238
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
8.2
|
FUNDAMENTAL REQUIREMENTS
|
Technical
|
411239
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
8.2.1
|
General
|
Technical
|
411240
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
8.2.2
|
Safety of people
|
Technical
|
411241
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
8.2.3
|
Protection of equipment
|
Technical
|
411242
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
8.2.4
|
Support operational security
|
Technical
|
411243
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
8.3
|
RISK MANAGEMENT AND DUE DILIGENCE
|
Technical
|
411244
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
8.3.1
|
General
|
Technical
|
411245
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
8.3.2
|
Touch and step voltage hazards and risks
|
Technical
|
411246
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
8.4
|
DESIGN
|
Technical
|
411247
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
8.4.1
|
Introduction
|
Technical
|
411248
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
8.4.2
|
Design process overview
|
Technical
|
411249
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
8.4.3
|
Data gathering
|
Technical
|
411250
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
8.4.4
|
Initial concept design
|
Technical
|
411251
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
8.4.4.1
|
General
|
Technical
|
411252
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
8.4.4.2
|
Fault current
|
Technical
|
411253
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
8.4.4.3
|
Earth fault duration
|
Technical
|
411254
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
8.4.4.4
|
Soil resistivity
|
Technical
|
411255
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
8.4.4.5
|
Layout practicalities
|
Technical
|
411256
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
8.4.4.6
|
Coordinated design
|
Technical
|
411257
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
8.4.4.7
|
Current injection
|
Technical
|
411258
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
8.4.4.8
|
Special considerations
|
Technical
|
411259
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
8.4.5
|
Determine design EPR
|
Technical
|
411260
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
8.4.6
|
Power frequency design
|
Technical
|
411261
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
8.4.6.1
|
General
|
Technical
|
411262
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
8.4.6.2
|
Earthing conductor layout
|
Technical
|
411263
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
8.4.6.3
|
Dimensioning of earthing conductors
|
Technical
|
411264
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
8.4.6.4
|
Transferred potentials
|
Technical
|
411265
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
8.4.6.5
|
Hazard location identification
|
Technical
|
411266
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
8.4.7
|
Safety criteria for design
|
Technical
|
411267
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
8.4.7.1
|
Safety criteria
|
Technical
|
411268
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
8.4.7.2
|
Risk quantification and individually derived safety criteria
|
Technical
|
411269
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
8.4.7.3
|
Guidance on standard safety criteria
|
Technical
|
411270
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
8.4.7.4
|
Safety criteria within other standards and guidelines
|
Technical
|
411271
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
8.4.8
|
Perform direct probabilistic design
|
Technical
|
411272
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
8.4.9
|
Mitigation/redesign
|
Technical
|
411273
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
8.4.10
|
Transient design
|
Technical
|
411274
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
8.5
|
CONSTRUCTION
|
Technical
|
411275
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
8.6
|
COMMISSIONING AND ONGOING MONITORING
|
Technical
|
411276
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
8.7
|
MAINTENANCE, MODIFICATION AND REFURBISHMENT
|
Technical
|
413277
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
8.8
|
TESTING
|
Testing
|
413278
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
8.9
|
DOCUMENTATION
|
Technical
|
413279
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
9.1
|
INSPECTIONS AND TESTS
|
Testing
|
413280
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
9.2
|
DOCUMENTATION AND RECORDS
|
Technical
|
411281
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
9.3
|
VERIFICATION OF SPECIFIED PERFORMANCES
|
Technical
|
411282
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
9.4
|
TESTS DURING INSTALLATION AND COMMISSIONING
|
Technical
|
411283
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
9.5
|
TRIAL RUN
|
Technical
|
411284
|
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
|
10
|
O P E R A T I O N A N D M A I N T E N A N C E M A N U A L
|
Technical
|
511001
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
4.1
|
General requirements
|
Technical
|
511002
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
4.2
|
Documentation
|
Technical
|
511003
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
4.3
|
Initial inspection
|
Technical
|
512004
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
4.4
|
Assurance of conformity of equipment
|
Unsafe
|
511005
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
4.4.1
|
Equipment with certificates according to IEC standards
|
Technical
|
512006
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
4.4.2
|
Equipment without certificates according to IEC standards
|
Unsafe
|
511007
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
4.4.3
|
Selection of repaired, second hand or existing equipment
|
Technical
|
511008
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
4.5
|
Qualifications of personnel
|
Technical
|
511009
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
5.1
|
Information requirements
|
Technical
|
511010
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
5.2
|
Zones
|
Technical
|
511011
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
5.3
|
Relationship between equipment protection levels (EPLs) and zones
|
Technical
|
511012
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
5.4.1
|
General
|
Technical
|
512013
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
5.4.2
|
Relationship between EPLs and types of protection
|
Unsafe
|
511014
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
5.4.3
|
Equipment for use in locations requiring EPL "Ga" or "Da"
|
Technical
|
511015
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
5.4.4
|
Equipment for use in locations requiring EPL "Gb" or "Db"
|
Technical
|
511016
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
5.4.5
|
Equipment for use in locations requiring EPL "Gc" or "Dc"
|
Technical
|
511017
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
5.5
|
Selection according to equipment grouping
|
Technical
|
511018
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
5.6.1
|
General
|
Technical
|
511019
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
5.6.2
|
Gas or vapour
|
Technical
|
511020
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
5.6.3.1
|
General
|
Technical
|
511021
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
5.6.3.2
|
Temperature limitations because of the presence of dust clouds
|
Technical
|
511022
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
5.6.3.3
|
Temperature limitation because of presence of dust layers
|
Technical
|
511023
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
5.6.3.4
|
Unavoidable dust layers
|
Technical
|
511024
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
5.7.1
|
General
|
Technical
|
511025
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
5.7.2
|
Ignition process
|
Technical
|
511026
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
5.8.1
|
General
|
Technical
|
511027
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
5.8.2
|
Ignition process
|
Technical
|
511028
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
5.9
|
Selection to cover external influences
|
Technical
|
511029
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
5.10.1
|
General
|
Technical
|
511030
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
5.10.2
|
Transportable and portable equipment
|
Technical
|
511031
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
5.10.3
|
Personal equipment
|
Technical
|
511032
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
5.11.1
|
General
|
Technical
|
511033
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
5.11.2
|
Environmental Factors for "Ex" machine installation
|
Technical
|
511034
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
5.11.3
|
Power and accessory connections, grounding
|
Technical
|
511035
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
5.11.4
|
Motors fed from a converter supply
|
Technical
|
511036
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
5.12
|
Luminaires
|
Technical
|
511037
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
5.13.1
|
General
|
Technical
|
511038
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
5.13.2
|
Specific requirements for explosive dust atmospheres
|
Technical
|
511039
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
5.13.3
|
Location
|
Technical
|
511040
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
5.14.1
|
Charging of secondary cells and batteries
|
Technical
|
511041
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
5.14.2
|
Ventilation
|
Technical
|
511042
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
5.15.1
|
General
|
Technical
|
511043
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
5.15.2
|
Passive RFID tags
|
Technical
|
511044
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
5.15.3
|
Mounting RFID tags
|
Technical
|
511045
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
5.16
|
Gas detection equipment
|
Technical
|
511046
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
6.1
|
Light metals as construction materials
|
Technical
|
511047
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
6.2
|
Danger from live parts
|
Technical
|
511048
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
6.3.2
|
TN type of system earthing
|
Technical
|
511049
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
6.3.3
|
TT type of system earthing
|
Technical
|
511050
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
6.3.4
|
IT type of system earthing
|
Technical
|
511051
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
6.3.5
|
SELV and PELV systems
|
Technical
|
511052
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
6.3.6
|
Electrical separation
|
Technical
|
511053
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
6.3.7
|
Non Ex electrical equipment above hazardous areas
|
Technical
|
511054
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
6.4.1
|
General
|
Technical
|
511055
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
6.4.2
|
Temporary bonding
|
Technical
|
511056
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
6.5.2
|
Avoidance of a build-up of electrostatic charge on construction and protecting parts for locations requiring EPL "Ga", " Gb" and "Gc"
|
Technical
|
511057
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
6.5.3
|
Avoidance of a build-up of electrostatic charge on construction and protecting parts for locations requiring EPL "Da", " Db" and "Dc"
|
Technical
|
511058
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
6.6
|
Lightning protection
|
Technical
|
511059
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
6.7.1
|
General
|
Technical
|
511060
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
6.7.2
|
Radio frequency received in hazardous areas
|
Technical
|
511061
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
6.8
|
Cathodically protected metallic parts
|
Technical
|
511062
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
6.9
|
Ignition by optical radiation
|
Technical
|
511063
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
7
|
Electrical protection
|
Technical
|
511064
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
8.2
|
Switch-off
|
Technical
|
511065
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
8.3
|
Electrical isolation
|
Technical
|
511066
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
9.1
|
General
|
Technical
|
511067
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
9.2
|
Aluminium conductors
|
Technical
|
511068
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
9.3.1
|
General
|
Technical
|
512069
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
9.3.2
|
Cables for fixed installations
|
Unsafe
|
512070
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
9.3.3
|
Flexible cables for fixed installations
|
Unsafe
|
512071
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
9.3.4
|
Flexible cables supplying transportable and portable equipment
|
Unsafe
|
511072
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
9.3.5
|
Single insulated wires
|
Technical
|
511073
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
9.3.6
|
Overhead lines
|
Technical
|
512074
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
9.3.7
|
Avoidance of damage
|
Unsafe
|
511075
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
9.3.8
|
Cable surface temperature
|
Technical
|
511076
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
9.3.9
|
Resistance to flame propagation
|
Technical
|
512077
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
9.4
|
Conduit systems
|
Unsafe
|
511078
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
9.5
|
Additional requirements
|
Technical
|
511079
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
9.6.1
|
Circuits traversing a hazardous area
|
Technical
|
511080
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
9.6.2
|
Terminations
|
Technical
|
511081
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
9.6.3
|
Unused cores
|
Technical
|
511082
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
9.6.4
|
Openings in walls
|
Technical
|
511083
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
9.6.5
|
Passage and collection of flammables
|
Technical
|
511084
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
9.6.6
|
Accumulation of dust
|
Technical
|
511085
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
10.1
|
General
|
Technical
|
511086
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
10.2
|
Selection of cable glands
|
Technical
|
511087
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
10.3
|
Connections of cables to equipment
|
Technical
|
511088
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
10.5
|
Unused openings
|
Technical
|
511089
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
10.6.1
|
General
|
Technical
|
511090
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
10.6.2
|
Selection of cable glands
|
Technical
|
511091
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
10.7
|
Additional requirements for type of protection "t" - Protection by enclosure
|
Technical
|
511092
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
10.8
|
Additional requirements for type of protection "nR" - Restricted breathing enclosure
|
Technical
|
511093
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
11.1
|
General
|
Technical
|
511094
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
11.2.1
|
Motors with a converter supply
|
Technical
|
511095
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
11.2.2
|
Reduced-voltage starting (soft starting)
|
Technical
|
511096
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
11.3.1
|
Mains-operated
|
Technical
|
511097
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
11.3.2
|
Winding temperature sensors
|
Technical
|
511098
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
11.3.3
|
Machines with rated voltage greater than 1 kV
|
Technical
|
511099
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
11.3.4
|
Motors with converter supply
|
Technical
|
511100
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
11.3.5
|
Reduced-voltage starting (soft starting)
|
Technical
|
511101
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
11.4.1
|
Motors with a converter supply
|
Technical
|
511102
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
11.4.2
|
Reduced-voltage starting (soft starting)
|
Technical
|
511103
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
11.5.1
|
Motors with a converter supply
|
Technical
|
511104
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
11.5.2
|
Reduced-voltage starting
|
Technical
|
511105
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
11.6.1
|
Motors with converter supply
|
Technical
|
511106
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
11.6.2
|
Reduced-voltage starting (soft starting)
|
Technical
|
511107
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
11.6.3
|
Machines with rated voltage greater than 1 kV
|
Technical
|
511108
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
12
|
Luminaires
|
Technical
|
511109
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
13.1
|
General
|
Technical
|
511110
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
13.2
|
Temperature monitoring
|
Technical
|
511111
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
13.3
|
Limiting temperature
|
Technical
|
511112
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
13.4
|
Safety device
|
Technical
|
511113
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
13.5
|
Electrical trace heating systems
|
Technical
|
511114
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
14.1
|
General
|
Technical
|
512115
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
14.3
|
Protection of flameproof joints
|
Unsafe
|
512116
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
14.4
|
Conduit systems
|
Unsafe
|
511117
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
15.1
|
General
|
Technical
|
511118
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
15.2
|
Maximum dissipated power of terminal box enclosures
|
Technical
|
511119
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
16.1
|
General
|
Technical
|
511120
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
16.2
|
Equipment
|
Technical
|
511121
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
16.2.2.1
|
General
|
Technical
|
511122
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
16.2.2.2
|
Electrical parameters of cables
|
Technical
|
511123
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
16.2.2.3
|
Earthing of conducting screens
|
Technical
|
511124
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
16.2.2.4
|
Cable armour bonding
|
Technical
|
511125
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
16.2.2.5.1
|
General
|
Technical
|
511126
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
16.2.2.5.2
|
Conductors
|
Technical
|
511127
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
16.2.2.5.3
|
Unused cores in cables
|
Technical
|
511128
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
16.2.2.6
|
Marking of cables
|
Technical
|
511129
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
16.2.2.7
|
Cables carrying more than one intrinsically safe circuit
|
Technical
|
511130
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
16.2.2.8
|
Types of cables carrying more than one intrinsically safe circuit and applicable fault considerations
|
Technical
|
511131
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
16.2.3
|
Earthing of intrinsically safe circuits
|
Technical
|
511132
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
16.2.4.1
|
General
|
Technical
|
511133
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
16.2.4.2
|
Descriptive system document
|
Technical
|
511134
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
16.2.4.3
|
Intrinsically safe circuits with only one source of power
|
Technical
|
511135
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
16.2.4.4
|
Intrinsically safe circuits with more than one associated apparatus
|
Technical
|
511136
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
16.3
|
Installations to meet the requirements of EPL "Ga" or "Da"
|
Technical
|
511137
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
16.4
|
Simple apparatus
|
Technical
|
511138
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
16.5.1
|
General
|
Technical
|
511139
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
16.5.3
|
Terminal boxes with more than one intrinsically safe circuit
|
Technical
|
511140
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
16.5.4
|
Terminal boxes with non-intrinsically safe and intrinsically safe circuits
|
Technical
|
511141
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
16.5.5
|
Plugs and sockets used for external connections
|
Technical
|
511142
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
16.6
|
Special applications
|
Technical
|
511143
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
17.1
|
General
|
Technical
|
511144
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
17.2.1
|
General
|
Technical
|
511145
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
17.2.2
|
Ducting
|
Technical
|
511146
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
17.2.3.1
|
General
|
Technical
|
511147
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
17.2.3.2.1
|
General
|
Technical
|
511148
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
17.2.3.2.2
|
Automatic switch-off
|
Technical
|
511149
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
17.2.3.2.3
|
Alarm
|
Technical
|
511150
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
17.2.3.3
|
Equipment with an internal source of release
|
Technical
|
511151
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
17.2.4
|
Multiple pressurized enclosures with a common safety device
|
Technical
|
511152
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
17.2.5
|
Purging
|
Technical
|
511153
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
17.2.6
|
Protective gas
|
Technical
|
511154
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
17.3.1
|
Sources of protective gas
|
Technical
|
511155
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
17.3.2
|
Automatic switch-off
|
Technical
|
511156
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
17.3.3
|
Alarm
|
Technical
|
511157
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
17.3.4
|
Common source of protective gas
|
Technical
|
511158
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
17.3.5
|
Switching on electrical supply
|
Technical
|
511159
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
17.4.1
|
Pressurized rooms
|
Technical
|
511160
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
17.4.2
|
Analyser houses
|
Technical
|
511161
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
18.1
|
General
|
Technical
|
511162
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
18.2
|
"nR" equipment
|
Technical
|
511163
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
18.3
|
Combinations of terminals and conductors for general connection and junction boxes
|
Technical
|
511164
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
18.4
|
Conductor terminations
|
Technical
|
511165
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
19.1
|
General
|
Technical
|
511166
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
19.2
|
External connections
|
Technical
|
511167
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
20
|
Additional requirements for type of protection "q" - Powder filling
|
Technical
|
511168
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
21
|
Additional requirements for type of protection "m" - Encapsulation
|
Technical
|
511169
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
22
|
Additional requirements for type of protection "op" - Optical radiation
|
Technical
|
511170
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
23
|
Additional requirements for type of protection "t" - Protection by enclosure
|
Technical
|
621001
|
AS/NZS 4777.1:2016 Grid connection of energy systems via inverters Installation requirements
|
2.1
|
GENERAL
|
Technical
|
621002
|
AS/NZS 4777.1:2016 Grid connection of energy systems via inverters Installation requirements
|
2.3
|
GENERAL REQUIREMENTS FOR INVERTER ENERGY SYSTEMS (IES)
|
Technical
|
621003
|
AS/NZS 4777.1:2016 Grid connection of energy systems via inverters Installation requirements
|
3.1
|
GENERAL
|
Technical
|
621005
|
AS/NZS 4777.1:2016 Grid connection of energy systems via inverters Installation requirements
|
3.2.1
|
CONNECTIONS - General
|
Technical
|
621006
|
AS/NZS 4777.1:2016 Grid connection of energy systems via inverters Installation requirements
|
3.2.2
|
CONNECTIONS - Connection to switchboard
|
Technical
|
621007
|
AS/NZS 4777.1:2016 Grid connection of energy systems via inverters Installation requirements
|
3.2.3
|
CONNECTIONS - Connector or coupling connections to the IES
|
Technical
|
621008
|
AS/NZS 4777.1:2016 Grid connection of energy systems via inverters Installation requirements
|
3.3.1
|
SELECTION AND INSTALLATION OF WIRING SYSTEMS - General
|
Technical
|
621009
|
AS/NZS 4777.1:2016 Grid connection of energy systems via inverters Installation requirements
|
3.3.2
|
SELECTION AND INSTALLATION OF WIRING SYSTEMS - Installation method
|
Technical
|
621010
|
AS/NZS 4777.1:2016 Grid connection of energy systems via inverters Installation requirements
|
3.3.3
|
SELECTION AND INSTALLATION OF WIRING SYSTEMS - Voltage rise
|
Technical
|
621011
|
AS/NZS 4777.1:2016 Grid connection of energy systems via inverters Installation requirements
|
3.4.1
|
CONTROL AND PROTECTION - General
|
Technical
|
621012
|
AS/NZS 4777.1:2016 Grid connection of energy systems via inverters Installation requirements
|
3.4.2
|
CONTROL AND PROTECTION - Overcurrent protection
|
Technical
|
621013
|
AS/NZS 4777.1:2016 Grid connection of energy systems via inverters Installation requirements
|
3.4.3
|
CONTROL AND PROTECTION - Isolation switches
|
Technical
|
621015
|
AS/NZS 4777.1:2016 Grid connection of energy systems via inverters Installation requirements
|
3.4.5
|
CONTROL AND PROTECTION - Residual current devices (RCDs)
|
Technical
|
621016
|
AS/NZS 4777.1:2016 Grid connection of energy systems via inverters Installation requirements
|
3.4.6
|
CONTROL AND PROTECTION - Demand response mode (DRM)
|
Technical
|
621017
|
AS/NZS 4777.1:2016 Grid connection of energy systems via inverters Installation requirements
|
3.4.7
|
CONTROL AND PROTECTION - IES operational settings
|
Technical
|
621019
|
AS/NZS 4777.1:2016 Grid connection of energy systems via inverters Installation requirements
|
4.1
|
GENERAL
|
Technical
|
621020
|
AS/NZS 4777.1:2016 Grid connection of energy systems via inverters Installation requirements
|
4.2
|
CONNECTORS OR COUPLING CONNECTIONS
|
Technical
|
621021
|
AS/NZS 4777.1:2016 Grid connection of energy systems via inverters Installation requirements
|
4.3.1
|
CABLING - General requirements
|
Technical
|
621022
|
AS/NZS 4777.1:2016 Grid connection of energy systems via inverters Installation requirements
|
4.3.2
|
CABLING - Cable identification
|
Technical
|
621023
|
AS/NZS 4777.1:2016 Grid connection of energy systems via inverters Installation requirements
|
4.4
|
OVERCURRENT PROTECTION
|
Technical
|
621024
|
AS/NZS 4777.1:2016 Grid connection of energy systems via inverters Installation requirements
|
4.5
|
ISOLATION DEVICES
|
Technical
|
621025
|
AS/NZS 4777.1:2016 Grid connection of energy systems via inverters Installation requirements
|
5.1.1
|
EARTH FAULT DETECTION - General
|
Technical
|
621026
|
AS/NZS 4777.1:2016 Grid connection of energy systems via inverters Installation requirements
|
5.1.2
|
EARTH FAULT DETECTION - Insulation monitoring
|
Technical
|
621027
|
AS/NZS 4777.1:2016 Grid connection of energy systems via inverters Installation requirements
|
5.1.3
|
EARTH FAULT DETECTION - Residual current detection for PV IES
|
Technical
|
621028
|
AS/NZS 4777.1:2016 Grid connection of energy systems via inverters Installation requirements
|
5.2
|
SEGREGATION OF CIRCUITS
|
Technical
|
621029
|
AS/NZS 4777.1:2016 Grid connection of energy systems via inverters Installation requirements
|
5.3.1
|
ADDITIONAL INSTALLATION REQUIREMENTS - Inverter installation
|
Technical
|
621030
|
AS/NZS 4777.1:2016 Grid connection of energy systems via inverters Installation requirements
|
5.3.2
|
ADDITIONAL INSTALLATION REQUIREMENTS - Equipment weatherproofing
|
Technical
|
621031
|
AS/NZS 4777.1:2016 Grid connection of energy systems via inverters Installation requirements
|
5.4.1
|
ADDITIONAL REQUIREMENTS FOR MULTIPLE MODE IES - General
|
Technical
|
621032
|
AS/NZS 4777.1:2016 Grid connection of energy systems via inverters Installation requirements
|
5.4.2
|
ADDITIONAL REQUIREMENTS FOR MULTIPLE MODE IES - Additional inverter requirements
|
Technical
|
621033
|
AS/NZS 4777.1:2016 Grid connection of energy systems via inverters Installation requirements
|
5.4.3
|
ADDITIONAL REQUIREMENTS FOR MULTIPLE MODE IES - Circuit arrangement
|
Technical
|
621034
|
AS/NZS 4777.1:2016 Grid connection of energy systems via inverters Installation requirements
|
5.4.4
|
ADDITIONAL REQUIREMENTS FOR MULTIPLE MODE IES - RCDs on multiple mode inverter system final subcircuits
|
Technical
|
621035
|
AS/NZS 4777.1:2016 Grid connection of energy systems via inverters Installation requirements
|
5.5.1
|
MULTIPLE INVERTER INSTALLATIONS - General
|
Technical
|
621036
|
AS/NZS 4777.1:2016 Grid connection of energy systems via inverters Installation requirements
|
5.5.2
|
MULTIPLE INVERTER INSTALLATIONS - Single inverter or group of inverters with capacity no more than 5 kVA per phase
|
Technical
|
621038
|
AS/NZS 4777.1:2016 Grid connection of energy systems via inverters Installation requirements
|
5.5.4
|
MULTIPLE INVERTER INSTALLATIONS - Inverter energy systems (IES) on different distribution switchboards
|
Technical
|
621039
|
AS/NZS 4777.1:2016 Grid connection of energy systems via inverters Installation requirements
|
6.1
|
S I G N S A N D L A B E L S - GENERAL
|
Technical
|
621040
|
AS/NZS 4777.1:2016 Grid connection of energy systems via inverters Installation requirements
|
6.2
|
SIGNS FOR THE SWITCHBOARD TO WHICH THE IES IS DIRECTLY CONNECTED
|
Technical
|
621041
|
AS/NZS 4777.1:2016 Grid connection of energy systems via inverters Installation requirements
|
6.3
|
SIGNS FOR OTHER SWITCHBOARDS
|
Technical
|
621042
|
AS/NZS 4777.1:2016 Grid connection of energy systems via inverters Installation requirements
|
6.4
|
SIGNS FOR INVERTER LOCATIONS
|
Technical
|
621043
|
AS/NZS 4777.1:2016 Grid connection of energy systems via inverters Installation requirements
|
6.5
|
ENERGY SOURCE LABELLING
|
Technical
|
621044
|
AS/NZS 4777.1:2016 Grid connection of energy systems via inverters Installation requirements
|
6.6
|
DEMAND RESPONSE MODE (DRM) LABELLING
|
Technical
|
621045
|
AS/NZS 4777.1:2016 Grid connection of energy systems via inverters Installation requirements
|
6.7
|
SIGNS FOR SHUTDOWN PROCEDURE
|
Technical
|
621046
|
AS/NZS 4777.1:2016 Grid connection of energy systems via inverters Installation requirements
|
6.8
|
SIGNS LOCATED ADJACENT TO INVERTER(S)
|
Technical
|
621047
|
AS/NZS 4777.1:2016 Grid connection of energy systems via inverters Installation requirements
|
6.9
|
SIGNS FOR MULTIPLE SYSTEMS
|
Technical
|
621048
|
AS/NZS 4777.1:2016 Grid connection of energy systems via inverters Installation requirements
|
6.1
|
SIGNS FOR MULTIPLE ENERGY SOURCES
|
Technical
|
621049
|
AS/NZS 4777.1:2016 Grid connection of energy systems via inverters Installation requirements
|
6.11
|
SIGNS FOR MULTIPLE MODE IES (INCLUDING SYSTEMS WITH STANDALONE FUNCTIONALITY)
|
Technical
|
621050
|
AS/NZS 4777.1:2016 Grid connection of energy systems via inverters Installation requirements
|
6.12
|
SIGNS FOR EMERGENCY SERVICES
|
Technical
|
621051
|
AS/NZS 4777.1:2016 Grid connection of energy systems via inverters Installation requirements
|
7.1
|
SYSTEM DOCUMENTATION AND COMMISSIONING - GENERAL
|
Technical
|
621052
|
AS/NZS 4777.1:2016 Grid connection of energy systems via inverters Installation requirements
|
7.2
|
SYSTEM DOCUMENTATION AND COMMISSIONING - MANUAL
|
Technical
|
621053
|
AS/NZS 4777.1:2016 Grid connection of energy systems via inverters Installation requirements
|
7.3.1
|
SYSTEM DOCUMENTATION AND COMMISSIONING - VERIFICATION - General
|
Technical
|
623054
|
AS/NZS 4777.1:2016 Grid connection of energy systems via inverters Installation requirements
|
7.3.2
|
VERIFICATION - Initial verification
|
Testing
|
623055
|
AS/NZS 4777.1:2016 Grid connection of energy systems via inverters Installation requirements
|
7.3.3
|
VERIFICATION - Periodic verification
|
Testing
|
621056
|
AS/NZS 4777.1:2016 Grid connection of energy systems via inverters Installation requirements
|
7.3.4
|
VERIFICATION - Alterations, additions and repairs
|
Technical
|
621057
|
AS/NZS 4777.1:2016 Grid connection of energy systems via inverters Installation requirements
|
7.4
|
VISUAL INSPECTION
|
Technical
|
623058
|
AS/NZS 4777.1:2016 Grid connection of energy systems via inverters Installation requirements
|
7.5
|
TESTING
|
Testing
|
621059
|
AS/NZS 4777.1:2016 Grid connection of energy systems via inverters Installation requirements
|
7.6
|
COMMISSIONING
|
Technical
|
641002
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
2.1.1
|
Configuration - General
|
Technical
|
641003
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
2.1.2
|
Configuration - PV system architectures
|
Technical
|
641004
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
2.1.3
|
Configuration - Array electrical diagrams
|
Technical
|
641006
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
2.1.5
|
Configuration - Strings constructed using d.c. conditioning units
|
Technical
|
641007
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
2.1.6
|
Configuration - Series-parallel configuration
|
Technical
|
641008
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
2.1.7
|
Configuration - Batteries connected to systems
|
Technical
|
641010
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
2.2.1
|
MECHANICAL DESIGN - General
|
Technical
|
641011
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
2.2.2
|
MECHANICAL DESIGN - Thermal aspects
|
Technical
|
641012
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
2.2.3
|
MECHANICAL DESIGN - Mechanical loads on PV structures
|
Technical
|
641013
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
2.2.5
|
MECHANICAL DESIGN - Wind
|
Technical
|
641014
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
2.2.6
|
MECHANICAL DESIGN - Snow/ice accumulation
|
Technical
|
641015
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
2.2.7
|
MECHANICAL DESIGN - Corrosion
|
Technical
|
641016
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
2.2.8
|
MECHANICAL DESIGN - Additional requirements for PV modules mounted on vehicles
|
Technical
|
641017
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
3.1
|
GENERAL
|
Technical
|
642018
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
3.2
|
PROTECTION AGAINST ELECTRIC SHOCK
|
Unsafe
|
641019
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
3.3.2
|
PROTECTION AGAINST OVERCURRENT - Requirement for overcurrent protection
|
Technical
|
641020
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
3.3.3
|
PROTECTION AGAINST OVERCURRENT - Overcurrent protection in PV systems connected to batteries
|
Technical
|
641021
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
3.3.4
|
PROTECTION AGAINST OVERCURRENT - String overcurrent protection
|
Technical
|
641023
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
3.3.6
|
PROTECTION AGAINST OVERCURRENT - Overcurrent protection location
|
Technical
|
641024
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
3.4
|
PROTECTION AGAINST EARTH FAULTS
|
Technical
|
641025
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
3.4.1
|
PROTECTION AGAINST EARTH FAULTS - General
|
Technical
|
641026
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
3.4.2
|
Systems with direct functional earthing of the PV array
|
Technical
|
641027
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
3.4.3
|
PROTECTION AGAINST EARTH FAULTS - Earth fault alarm (see Appendix H, Table H1)
|
Technical
|
641030
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
3.5.2
|
Protection against overvoltage
|
Technical
|
641032
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
4.1
|
GENERAL
|
Technical
|
641033
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
4.2
|
PV ARRAY MAXIMUM VOLTAGE
|
Technical
|
641034
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
4.3.1
|
COMPONENT REQUIREMENTS - General
|
Technical
|
641037
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
4.3.4
|
Circuit breakers
|
Technical
|
641040
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
4.3.7
|
Plugs, sockets and connectors
|
Technical
|
641042
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
4.3.9
|
Bypass diodes
|
Technical
|
641043
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
4.3.10
|
Blocking diodes
|
Technical
|
641044
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
4.3.11
|
Power conversion equipment (PCE)
|
Technical
|
641045
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
4.3.12
|
Small micro inverter installations
|
Technical
|
641050
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
4.5
|
COMMISSIONING
|
Technical
|
641051
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
5.1
|
EQUIPMENT MARKING
|
Technical
|
641052
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
5.2
|
REQUIREMENTS FOR LABELS AND SIGNS
|
Technical
|
641053
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
5.3.1
|
LABELLING/SIGNS FOR PV CABLES AND ENCLOSURES - Wiring identification
|
Technical
|
641054
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
5.3.2
|
LABELLING/SIGNS FOR PV CABLES AND ENCLOSURES - Signs for PV array and PV string junction boxes
|
Technical
|
641055
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
5.4.1
|
FIRE EMERGENCY INFORMATION - Voltage and current sign
|
Technical
|
641056
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
5.4.2
|
FIRE EMERGENCY INFORMATION - Warning sign
|
Technical
|
641057
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
5.5.1
|
LABELLING/SIGNS FOR DISCONNECTION DEVICES - General
|
Technical
|
641058
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
5.5.2
|
LABELLING/SIGNS FOR DISCONNECTION DEVICES - PV array disconnecting device
|
Technical
|
641059
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
5.5.3
|
LABELLING/SIGNS FOR DISCONNECTION DEVICES - Shutdown procedure
|
Technical
|
641060
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
5.5.4
|
LABELLING/SIGNS FOR DISCONNECTION DEVICES - Sign for systems over 600 V
|
Technical
|
641061
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
5.6
|
LABELLING OF FUSE HOLDERS
|
Technical
|
641062
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
5.7
|
DOCUMENTATION
|
Technical
|
641063
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
B2
|
D.C. SWITCH-DISCONNECTOR VOLTAGE RATING REQUIREMENTS
|
Technical
|
643064
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
D2
|
COMMISSIONING TESTS
|
Testing
|
643065
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
D3
|
PV ARRAY-D.C. VOLTAGE
|
Technical
|
641066
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
F8
|
SELECTION OF SPDs APPERTAINING TO PROTECTION LEVEL VP AND SYSTEM IMMUNITY
|
Technical
|
641067
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
F9
|
EARTHING OF SPDs
|
Technical
|
641068
|
AS/NZS 5033:2014 +A2 Installation and safety requirements for photovoltaic (PV) arrays
|
F10
|
CROSS-SECTION OF CONNECTING CONDUCTORS TO SPDs ON THE D.C.SIDE OF PV INSTALLATIONS
|
Technical
|
651001
|
AS/NZS 4509.1:2009 (R2017) Stand-alone power systems Part 1: Safety and installation
|
2.1
|
A.C. OUTPUT VOLTAGE
|
Technical
|
651002
|
AS/NZS 4509.1:2009 (R2017) Stand-alone power systems Part 1: Safety and installation
|
2.2
|
APPLICATION OF AS/NZS 3000
|
Technical
|
651003
|
AS/NZS 4509.1:2009 (R2017) Stand-alone power systems Part 1: Safety and installation
|
2.3
|
SIGNS
|
Technical
|
651004
|
AS/NZS 4509.1:2009 (R2017) Stand-alone power systems Part 1: Safety and installation
|
2.4
|
INFORMATION SIGN FOR EMERGENCY SERVICES
|
Technical
|
651005
|
AS/NZS 4509.1:2009 (R2017) Stand-alone power systems Part 1: Safety and installation
|
2.5
|
SHUTDOWN PROCEDURE
|
Technical
|
651006
|
AS/NZS 4509.1:2009 (R2017) Stand-alone power systems Part 1: Safety and installation
|
2.6
|
IDENTIFICATION AND LOCATION OF EQUIPMENT
|
Technical
|
651007
|
AS/NZS 4509.1:2009 (R2017) Stand-alone power systems Part 1: Safety and installation
|
2.7
|
METERS AND INFORMATIVE DISPLAYS
|
Technical
|
651008
|
AS/NZS 4509.1:2009 (R2017) Stand-alone power systems Part 1: Safety and installation
|
2.8
|
MECHANICAL AND THERMAL PROTECTION OF EQUIPMENT
|
Technical
|
651009
|
AS/NZS 4509.1:2009 (R2017) Stand-alone power systems Part 1: Safety and installation
|
3.1
|
CABLE PROTECTION
|
Technical
|
651010
|
AS/NZS 4509.1:2009 (R2017) Stand-alone power systems Part 1: Safety and installation
|
3.2
|
ELECTRICAL PROTECTION
|
Technical
|
651011
|
AS/NZS 4509.1:2009 (R2017) Stand-alone power systems Part 1: Safety and installation
|
3.3
|
EQUIPMENT LAYOUT
|
Technical
|
651012
|
AS/NZS 4509.1:2009 (R2017) Stand-alone power systems Part 1: Safety and installation
|
3.4.1
|
WIRING ISSUES - D.C. Losses
|
Technical
|
651013
|
AS/NZS 4509.1:2009 (R2017) Stand-alone power systems Part 1: Safety and installation
|
3.4.2
|
ELV Cabling Voltage Drop
|
Technical
|
651014
|
AS/NZS 4509.1:2009 (R2017) Stand-alone power systems Part 1: Safety and installation
|
3.4.3
|
Segregation Of Circuits
|
Technical
|
651015
|
AS/NZS 4509.1:2009 (R2017) Stand-alone power systems Part 1: Safety and installation
|
3.4.4
|
D.C. Cabling Inductance
|
Technical
|
651016
|
AS/NZS 4509.1:2009 (R2017) Stand-alone power systems Part 1: Safety and installation
|
4.4.2
|
Point of supply with earthed neutral
|
Technical
|
651017
|
AS/NZS 4509.1:2009 (R2017) Stand-alone power systems Part 1: Safety and installation
|
4.4.3
|
Separated supply
|
Technical
|
651018
|
AS/NZS 4509.1:2009 (R2017) Stand-alone power systems Part 1: Safety and installation
|
4.5.1
|
SYSTEMS FEEDING A SINGLE ELECTRICAL MAIN (INSTALLATION) SWITCHBOARD - General
|
Technical
|
651019
|
AS/NZS 4509.1:2009 (R2017) Stand-alone power systems Part 1: Safety and installation
|
4.5.2
|
Isolation and protection of consumers mains
|
Technical
|
651020
|
AS/NZS 4509.1:2009 (R2017) Stand-alone power systems Part 1: Safety and installation
|
4.5.3
|
Earthing
|
Technical
|
651021
|
AS/NZS 4509.1:2009 (R2017) Stand-alone power systems Part 1: Safety and installation
|
4.5.4
|
Protection
|
Technical
|
651022
|
AS/NZS 4509.1:2009 (R2017) Stand-alone power systems Part 1: Safety and installation
|
4.6.1
|
A.C. SYSTEMS SUPPLYING SEVERAL BUILDINGS - General
|
Technical
|
651023
|
AS/NZS 4509.1:2009 (R2017) Stand-alone power systems Part 1: Safety and installation
|
4.6.2
|
Earthing
|
Technical
|
651024
|
AS/NZS 4509.1:2009 (R2017) Stand-alone power systems Part 1: Safety and installation
|
5.1.1
|
PHOTOVOLTAIC ARRAYS - Installation
|
Technical
|
651025
|
AS/NZS 4509.1:2009 (R2017) Stand-alone power systems Part 1: Safety and installation
|
5.1.2
|
Sizing
|
Technical
|
651026
|
AS/NZS 4509.1:2009 (R2017) Stand-alone power systems Part 1: Safety and installation
|
5.2.1
|
WIND TURBINE GENERATORS - General
|
Technical
|
651027
|
AS/NZS 4509.1:2009 (R2017) Stand-alone power systems Part 1: Safety and installation
|
5.2.3
|
Footings
|
Technical
|
651028
|
AS/NZS 4509.1:2009 (R2017) Stand-alone power systems Part 1: Safety and installation
|
5.2.4
|
Tower
|
Technical
|
651029
|
AS/NZS 4509.1:2009 (R2017) Stand-alone power systems Part 1: Safety and installation
|
5.3.2
|
HYDRO GENERATORS - Installation
|
Technical
|
651030
|
AS/NZS 4509.1:2009 (R2017) Stand-alone power systems Part 1: Safety and installation
|
6.1
|
GENERAL
|
Technical
|
651031
|
AS/NZS 4509.1:2009 (R2017) Stand-alone power systems Part 1: Safety and installation
|
6.2
|
INSTALLATION OF GENERATING SETS
|
Technical
|
651032
|
AS/NZS 4509.1:2009 (R2017) Stand-alone power systems Part 1: Safety and installation
|
6.3
|
AUTOMATIC-START WARNING
|
Technical
|
651033
|
AS/NZS 4509.1:2009 (R2017) Stand-alone power systems Part 1: Safety and installation
|
6.4.1
|
FUEL STORAGE - General requirements
|
Technical
|
651034
|
AS/NZS 4509.1:2009 (R2017) Stand-alone power systems Part 1: Safety and installation
|
6.4.2
|
Australian requirements
|
Technical
|
651035
|
AS/NZS 4509.1:2009 (R2017) Stand-alone power systems Part 1: Safety and installation
|
7.1
|
GENERAL
|
Technical
|
651036
|
AS/NZS 4509.1:2009 (R2017) Stand-alone power systems Part 1: Safety and installation
|
7.2
|
LOCATION OF BATTERIES
|
Technical
|
651037
|
AS/NZS 4509.1:2009 (R2017) Stand-alone power systems Part 1: Safety and installation
|
7.3.1
|
EQUIPMENT ROOM OR BATTERY ENCLOSURE - General
|
Technical
|
651038
|
AS/NZS 4509.1:2009 (R2017) Stand-alone power systems Part 1: Safety and installation
|
7.3.2
|
Lighting
|
Technical
|
651039
|
AS/NZS 4509.1:2009 (R2017) Stand-alone power systems Part 1: Safety and installation
|
7.3.3
|
Socket-outlets
|
Technical
|
651040
|
AS/NZS 4509.1:2009 (R2017) Stand-alone power systems Part 1: Safety and installation
|
7.3.4
|
Fences
|
Technical
|
651041
|
AS/NZS 4509.1:2009 (R2017) Stand-alone power systems Part 1: Safety and installation
|
7.4
|
LOCATION OF BATTERY PROTECTION EQUIPMENT
|
Technical
|
651042
|
AS/NZS 4509.1:2009 (R2017) Stand-alone power systems Part 1: Safety and installation
|
7.5.1
|
INSTALLATION - Mandatory requirements
|
Technical
|
651043
|
AS/NZS 4509.1:2009 (R2017) Stand-alone power systems Part 1: Safety and installation
|
8.1
|
TEMPERATURE SENSING
|
Technical
|
651044
|
AS/NZS 4509.1:2009 (R2017) Stand-alone power systems Part 1: Safety and installation
|
8.3
|
BATTERY CHARGERS
|
Technical
|
651045
|
AS/NZS 4509.1:2009 (R2017) Stand-alone power systems Part 1: Safety and installation
|
9.1
|
CABLING
|
Technical
|
651046
|
AS/NZS 4509.1:2009 (R2017) Stand-alone power systems Part 1: Safety and installation
|
9.3.2
|
Inverters with separation
|
Technical
|
651047
|
AS/NZS 4509.1:2009 (R2017) Stand-alone power systems Part 1: Safety and installation
|
9.3.2
|
Inverters without separation
|
Technical
|
651048
|
AS/NZS 4509.1:2009 (R2017) Stand-alone power systems Part 1: Safety and installation
|
9.4.1
|
CONNECTION OF GENERATORS TO INVERTERS - General
|
Technical
|
651049
|
AS/NZS 4509.1:2009 (R2017) Stand-alone power systems Part 1: Safety and installation
|
9.4.2
|
Connecting a generating set in parallel with an interactive inverter
|
Technical
|
651050
|
AS/NZS 4509.1:2009 (R2017) Stand-alone power systems Part 1: Safety and installation
|
10.1
|
GENERAL
|
Technical
|
651051
|
AS/NZS 4509.1:2009 (R2017) Stand-alone power systems Part 1: Safety and installation
|
10.2
|
WIRING
|
Technical
|
653052
|
AS/NZS 4509.1:2009 (R2017) Stand-alone power systems Part 1: Safety and installation
|
10.3
|
D.C. POLARITY
|
Testing
|
651053
|
AS/NZS 4509.1:2009 (R2017) Stand-alone power systems Part 1: Safety and installation
|
10.4
|
PRE-COMMISSIONING CHECKS
|
Technical
|
653054
|
AS/NZS 4509.1:2009 (R2017) Stand-alone power systems Part 1: Safety and installation
|
10.5
|
SYSTEM FUNCTIONAL TEST
|
Testing
|
651055
|
AS/NZS 4509.1:2009 (R2017) Stand-alone power systems Part 1: Safety and installation
|
11.1
|
GENERAL
|
Technical
|
651056
|
AS/NZS 4509.1:2009 (R2017) Stand-alone power systems Part 1: Safety and installation
|
11.2
|
SYSTEM MANUAL
|
Technical
|
651057
|
AS/NZS 4509.1:2009 (R2017) Stand-alone power systems Part 1: Safety and installation
|
11.3
|
SYSTEM AND BATTERY RECORD BOOK
|
Technical
|
651058
|
AS/NZS 4509.1:2009 (R2017) Stand-alone power systems Part 1: Safety and installation
|
11.4
|
GENERATING SET LOGBOOK
|
Technical
|
661001
|
AS/ NZS 3439.1:2002 Low-voltage switchgear and controlgear assemblies
|
4
|
Electrical characteristics of ASSEMBLIES
|
Technical
|
661002
|
AS/ NZS 3439.1:2002 Low-voltage switchgear and controlgear assemblies
|
4.1
|
Rated voltages
|
Technical
|
661003
|
AS/ NZS 3439.1:2002 Low-voltage switchgear and controlgear assemblies
|
4.1.1
|
Rated operational voltage (of a circuit of an ASSEMBLY)
|
Technical
|
661004
|
AS/ NZS 3439.1:2002 Low-voltage switchgear and controlgear assemblies
|
4.1.2
|
Rated insulation voltage (Ui) (of a circuit of an ASSEMBLY)
|
Technical
|
661005
|
AS/ NZS 3439.1:2002 Low-voltage switchgear and controlgear assemblies
|
4.1.3
|
Rated impulse withstand voltage (Uimp ) (of a circuit of an ASSEMBLY)
|
Technical
|
661006
|
AS/ NZS 3439.1:2002 Low-voltage switchgear and controlgear assemblies
|
4.2
|
Rated current (In) (of a circuit of an ASSEMBLY)
|
Technical
|
661007
|
AS/ NZS 3439.1:2002 Low-voltage switchgear and controlgear assemblies
|
4.3
|
Rated short-time current (Icw) (of a circuit of an ASSEMBLY)
|
Technical
|
661008
|
AS/ NZS 3439.1:2002 Low-voltage switchgear and controlgear assemblies
|
4.4
|
Rated peak withstand current (Ipk) (of a circuit of an ASSEMBLY)
|
Technical
|
661009
|
AS/ NZS 3439.1:2002 Low-voltage switchgear and controlgear assemblies
|
4.5
|
Rated conditional short-circuit current (Icc) (of a circuit of an ASSEMBLY)
|
Technical
|
661010
|
AS/ NZS 3439.1:2002 Low-voltage switchgear and controlgear assemblies
|
4.6
|
Rated fused short-circuit current (Icf) (of a circuit of an ASSEMBLY)
|
Technical
|
661011
|
AS/ NZS 3439.1:2002 Low-voltage switchgear and controlgear assemblies
|
4.7
|
Rated diversity factor
|
Technical
|
661012
|
AS/ NZS 3439.1:2002 Low-voltage switchgear and controlgear assemblies
|
4.8
|
Rated frequency
|
Technical
|
661013
|
AS/ NZS 3439.1:2002 Low-voltage switchgear and controlgear assemblies
|
5.1
|
Information to be given regarding the ASSEMBLY - Nameplates
|
Technical
|
661014
|
AS/ NZS 3439.1:2002 Low-voltage switchgear and controlgear assemblies
|
5.2
|
Markings
|
Technical
|
661015
|
AS/ NZS 3439.1:2002 Low-voltage switchgear and controlgear assemblies
|
5.3
|
Instructions for installation, operation and maintenance
|
Technical
|
661016
|
AS/ NZS 3439.1:2002 Low-voltage switchgear and controlgear assemblies
|
6.1
|
Normal service conditions
|
Technical
|
661017
|
AS/ NZS 3439.1:2002 Low-voltage switchgear and controlgear assemblies
|
6.1.1
|
Ambient air temperature
|
Technical
|
661018
|
AS/ NZS 3439.1:2002 Low-voltage switchgear and controlgear assemblies
|
6.1.2
|
Atmospheric conditions
|
Technical
|
661019
|
AS/ NZS 3439.1:2002 Low-voltage switchgear and controlgear assemblies
|
6.1.3
|
Altitude
|
Technical
|
661020
|
AS/ NZS 3439.1:2002 Low-voltage switchgear and controlgear assemblies
|
6.2
|
Special service conditions
|
Technical
|
661021
|
AS/ NZS 3439.1:2002 Low-voltage switchgear and controlgear assemblies
|
6.3
|
Conditions during transport, storage and erection
|
Technical
|
661022
|
AS/ NZS 3439.1:2002 Low-voltage switchgear and controlgear assemblies
|
7.1.1
|
Mechanical design - General
|
Technical
|
661023
|
AS/ NZS 3439.1:2002 Low-voltage switchgear and controlgear assemblies
|
7.1.2.1
|
Clearances, creepage distances and isolating distances
|
Technical
|
661024
|
AS/ NZS 3439.1:2002 Low-voltage switchgear and controlgear assemblies
|
7.1.2.2
|
Isolation of withdrawable parts
|
Technical
|
661025
|
AS/ NZS 3439.1:2002 Low-voltage switchgear and controlgear assemblies
|
7.1.2.3
|
Dielectric properties
|
Technical
|
661026
|
AS/ NZS 3439.1:2002 Low-voltage switchgear and controlgear assemblies
|
7.1.3
|
Terminals for external conductors
|
Technical
|
661027
|
AS/ NZS 3439.1:2002 Low-voltage switchgear and controlgear assemblies
|
7.2.1
|
Degree of protection
|
Technical
|
661028
|
AS/ NZS 3439.1:2002 Low-voltage switchgear and controlgear assemblies
|
7.2.2
|
Measures to take account of atmospheric humidity
|
Technical
|
661029
|
AS/ NZS 3439.1:2002 Low-voltage switchgear and controlgear assemblies
|
7.3
|
Temperature rise
|
Technical
|
661030
|
AS/ NZS 3439.1:2002 Low-voltage switchgear and controlgear assemblies
|
7.4
|
Protection against electric shock
|
Technical
|
661031
|
AS/ NZS 3439.1:2002 Low-voltage switchgear and controlgear assemblies
|
7.4.1.1
|
Protection by safety extra-low voltage
|
Technical
|
661032
|
AS/ NZS 3439.1:2002 Low-voltage switchgear and controlgear assemblies
|
7.4.2
|
Protection against direct contact
|
Technical
|
662033
|
AS/ NZS 3439.1:2002 Low-voltage switchgear and controlgear assemblies
|
7.4.2.1
|
Protection by insulation of live parts
|
Unsafe
|
661034
|
AS/ NZS 3439.1:2002 Low-voltage switchgear and controlgear assemblies
|
7.4.2.2
|
Protection by barriers or enclosures
|
Technical
|
661035
|
AS/ NZS 3439.1:2002 Low-voltage switchgear and controlgear assemblies
|
7.4.3
|
Protection against indirect contact
|
Technical
|
661036
|
AS/ NZS 3439.1:2002 Low-voltage switchgear and controlgear assemblies
|
7.4.3.1
|
Protection by using protective circuits
|
Technical
|
661037
|
AS/ NZS 3439.1:2002 Low-voltage switchgear and controlgear assemblies
|
7.4.3.2
|
Protection by measures other than using protective circuits
|
Technical
|
661038
|
AS/ NZS 3439.1:2002 Low-voltage switchgear and controlgear assemblies
|
7.4.4
|
Discharging of electrical charges
|
Technical
|
661039
|
AS/ NZS 3439.1:2002 Low-voltage switchgear and controlgear assemblies
|
7.4.5
|
Operating and maintenance gangways within ASSEMBLIES
|
Technical
|
661040
|
AS/ NZS 3439.1:2002 Low-voltage switchgear and controlgear assemblies
|
7.4.6
|
Requirements related to accessibility in service by authorized personnel
|
Technical
|
661041
|
AS/ NZS 3439.1:2002 Low-voltage switchgear and controlgear assemblies
|
7.5.1
|
Short-circuit protection and short-circuit withstand strength - General
|
Technical
|
661042
|
AS/ NZS 3439.1:2002 Low-voltage switchgear and controlgear assemblies
|
7.5.2
|
Information concerning short-circuit withstand strength
|
Technical
|
661043
|
AS/ NZS 3439.1:2002 Low-voltage switchgear and controlgear assemblies
|
7.5.3
|
Relationship between peak withstand current and short-time withstand current
|
Technical
|
661044
|
AS/ NZS 3439.1:2002 Low-voltage switchgear and controlgear assemblies
|
7.5.4
|
Co-ordination of short-circuit protective devices
|
Technical
|
661045
|
AS/ NZS 3439.1:2002 Low-voltage switchgear and controlgear assemblies
|
7.5.5
|
Circuits within an ASSEMBLY
|
Technical
|
661046
|
AS/ NZS 3439.1:2002 Low-voltage switchgear and controlgear assemblies
|
7.6.1
|
Switching devices and components installed in ASSEMBLIES - Seleection of
|
Technical
|
661047
|
AS/ NZS 3439.1:2002 Low-voltage switchgear and controlgear assemblies
|
7.6.2
|
Installation
|
Technical
|
661048
|
AS/ NZS 3439.1:2002 Low-voltage switchgear and controlgear assemblies
|
7.6.3
|
Fixed parts
|
Technical
|
661049
|
AS/ NZS 3439.1:2002 Low-voltage switchgear and controlgear assemblies
|
7.6.4
|
Removable parts and withdrawable parts
|
Technical
|
661050
|
AS/ NZS 3439.1:2002 Low-voltage switchgear and controlgear assemblies
|
7.6.5
|
Identification
|
Technical
|
661051
|
AS/ NZS 3439.1:2002 Low-voltage switchgear and controlgear assemblies
|
7.7
|
Internal separation of ASSEMBLIES
|
Technical
|
661052
|
AS/ NZS 3439.1:2002 Low-voltage switchgear and controlgear assemblies
|
7.7.1
|
By barriers or partitions (standard construction)
|
Technical
|
661053
|
AS/ NZS 3439.1:2002 Low-voltage switchgear and controlgear assemblies
|
7.7.2
|
By alternative means to standard construction
|
Technical
|
661054
|
AS/ NZS 3439.1:2002 Low-voltage switchgear and controlgear assemblies
|
7.8.1
|
Electrical connections inside an ASSEMBLY: bars and insulated conductors - General
|
Technical
|
661055
|
AS/ NZS 3439.1:2002 Low-voltage switchgear and controlgear assemblies
|
7.8.2
|
Dimensions and rating of busbars and insulated conductors
|
Technical
|
661056
|
AS/ NZS 3439.1:2002 Low-voltage switchgear and controlgear assemblies
|
7.8.3
|
Wiring
|
Technical
|
661057
|
AS/ NZS 3439.1:2002 Low-voltage switchgear and controlgear assemblies
|
7.9.1
|
Requirements for electronic equipment supply circuits - Input voltage variations
|
Technical
|
661058
|
AS/ NZS 3439.1:2002 Low-voltage switchgear and controlgear assemblies
|
7.9.2
|
Overvoltages
|
Technical
|
661059
|
AS/ NZS 3439.1:2002 Low-voltage switchgear and controlgear assemblies
|
7.9.3
|
Waveform
|
Technical
|
661060
|
AS/ NZS 3439.1:2002 Low-voltage switchgear and controlgear assemblies
|
7.9.4
|
Temporary variations in voltage and frequency
|
Technical
|
661061
|
AS/ NZS 3439.1:2002 Low-voltage switchgear and controlgear assemblies
|
7.10.1
|
Electromagnetic compatibility (EMC) - EMC environment
|
Technical
|
661062
|
AS/ NZS 3439.1:2002 Low-voltage switchgear and controlgear assemblies
|
7.10.2
|
Requirement for testing
|
Technical
|
661063
|
AS/ NZS 3439.1:2002 Low-voltage switchgear and controlgear assemblies
|
7.10.3
|
Immunity
|
Technical
|
661064
|
AS/ NZS 3439.1:2002 Low-voltage switchgear and controlgear assemblies
|
7.10.4
|
Emission
|
Technical
|
661065
|
AS/ NZS 3439.1:2002 Low-voltage switchgear and controlgear assemblies
|
7.11
|
Description of the types of electrical connections of functional units
|
Technical
|
661066
|
AS/ NZS 3439.1:2002 Low-voltage switchgear and controlgear assemblies
|
8.1
|
Test specifications - Classification of tests
|
Technical
|
661067
|
AS/ NZS 3439.1:2002 Low-voltage switchgear and controlgear assemblies
|
8.1.1
|
Type tests
|
Technical
|
661068
|
AS/ NZS 3439.1:2002 Low-voltage switchgear and controlgear assemblies
|
8.1.2
|
Routine tests
|
Technical
|
661069
|
AS/ NZS 3439.1:2002 Low-voltage switchgear and controlgear assemblies
|
8.1.3
|
Testing of devices and self-contained components incorporated in the ASSEMBLY
|
Technical
|
663070
|
AS/ NZS 3439.1:2002 Low-voltage switchgear and controlgear assemblies
|
8.2.1
|
Type tests - Verification of temperature-rise limits
|
Testing
|
663071
|
AS/ NZS 3439.1:2002 Low-voltage switchgear and controlgear assemblies
|
8.2.2
|
Verification of dielectric properties - General
|
Testing
|
663072
|
AS/ NZS 3439.1:2002 Low-voltage switchgear and controlgear assemblies
|
8.2.3
|
Verification of short-circuit withstand strength
|
Testing
|
663073
|
AS/ NZS 3439.1:2002 Low-voltage switchgear and controlgear assemblies
|
8.2.4
|
Verification of the effectiveness of the protective circuit
|
Testing
|
663074
|
AS/ NZS 3439.1:2002 Low-voltage switchgear and controlgear assemblies
|
8.2.5
|
Verification of clearances and creepage distances
|
Testing
|
663075
|
AS/ NZS 3439.1:2002 Low-voltage switchgear and controlgear assemblies
|
8.2.6
|
Verification of mechanical operation
|
Testing
|
663076
|
AS/ NZS 3439.1:2002 Low-voltage switchgear and controlgear assemblies
|
8.2.7
|
Verification of degree of protection and internal separation
|
Testing
|
663077
|
AS/ NZS 3439.1:2002 Low-voltage switchgear and controlgear assemblies
|
8.2.8
|
EMC tests
|
Testing
|
663078
|
AS/ NZS 3439.1:2002 Low-voltage switchgear and controlgear assemblies
|
8.3.1
|
Routine tests - Inspection of the ASSEMBLY including inspection of wiring and, if necessary, electrical operation test
|
Testing
|
663079
|
AS/ NZS 3439.1:2002 Low-voltage switchgear and controlgear assemblies
|
8.3.2
|
Dielectric test
|
Testing
|
663080
|
AS/ NZS 3439.1:2002 Low-voltage switchgear and controlgear assemblies
|
8.3.3
|
Checking of protective measures and of the electrical continuity of the protective circuits
|
Testing
|
663081
|
AS/ NZS 3439.1:2002 Low-voltage switchgear and controlgear assemblies
|
8.3.4
|
Verification of insulation resistance
|
Testing
|
671001
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
5.2.1
|
Voltage ratings - Rated voltage (Un) (of the ASSEMBLY)
|
Technical
|
671002
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
5.2.2
|
Rated operational voltage (Ue) (of a circuit of an ASSEMBLY)
|
Technical
|
671003
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
5.2.3
|
Rated insulation voltage (Ui) (of a circuit of an ASSEMBLY)
|
Technical
|
671004
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
5.2.4
|
Rated impulse withstand voltage (Uimp) (of the ASSEMBLY)
|
Technical
|
671005
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
5.3.1
|
Current ratings - Rated current of the ASSEMBLY (InA)
|
Technical
|
671006
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
5.3.2
|
Rated current of a circuit (Inc)
|
Technical
|
671007
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
5.3.3
|
Rated peak withstand current (Ipk)
|
Technical
|
671008
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
5.3.4
|
Rated short-time withstand current (Icw) (of a circuit of an ASSEMBLY)
|
Technical
|
671009
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
5.3.5
|
Rated conditional short-circuit current of an ASSEMBLY (Icc)
|
Technical
|
671010
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
5.4
|
Rated diversity factor (RDF)
|
Technical
|
671011
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
5.5
|
Rated frequency (fn)
|
Technical
|
671012
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
5.6
|
Other characteristics
|
Technical
|
671013
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
6.1
|
Information - ASSEMBLY designation marking
|
Technical
|
671014
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
6.2.1
|
Documentation - Information relating to the ASSEMBLY
|
Technical
|
671015
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
6.2.2
|
Instructions for handling, installation, operation and maintenance
|
Technical
|
671016
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
6.3
|
Device and/or component identification
|
Technical
|
671017
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
7.1.1
|
Ambient air temperature
|
Technical
|
671018
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
7.1.2
|
Humidity conditions
|
Technical
|
671019
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
7.1.3
|
Pollution degree
|
Technical
|
671020
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
7.1.4
|
Altitude
|
Technical
|
671021
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
7.2
|
Special service conditions
|
Technical
|
671022
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
7.3
|
Conditions during transport, storage and installation
|
Technical
|
671023
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
8.1.1
|
Strength of materials and parts - General
|
Technical
|
671024
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
8.1.2
|
Protection against corrosion
|
Technical
|
671025
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
8.1.3
|
Properties of insulating materials
|
Technical
|
671026
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
8.1.4
|
Resistance to ultra-violet radiation
|
Technical
|
671027
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
8.1.5
|
Mechanical strength
|
Technical
|
671028
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
8.1.6
|
Lifting provision
|
Technical
|
671029
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
8.2.1
|
Degree of protection provided by an ASSEMBLY enclosure - Protection against mechanical impact
|
Technical
|
671030
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
8.2.2
|
Protection against contact with live parts, ingress of solid foreign bodies and water
|
Technical
|
671031
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
8.2.3
|
ASSEMBLY with removable parts
|
Technical
|
671032
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
8.3.1
|
Clearances and creepage distances - General
|
Technical
|
671033
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
8.3.2
|
Clearances
|
Technical
|
671034
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
8.3.3
|
Creepage distances
|
Technical
|
671035
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
8.4.1
|
Protection against electric shock - General
|
Technical
|
672036
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
8.4.2
|
Basic protection
|
Unsafe
|
671037
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
8.4.3
|
Fault protection
|
Technical
|
671038
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
8.4.4
|
Protection by total insulation
|
Technical
|
671039
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
8.4.5
|
Limitation of steady-state touch current and charge
|
Technical
|
671040
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
8.4.6
|
Operating and servicing conditions
|
Technical
|
671041
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
8.5.1
|
Incorporation of switching devices and components - Fixed parts
|
Technical
|
671042
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
8.5.2
|
Removable parts
|
Technical
|
671043
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
8.5.3
|
Selection of switching devices and components
|
Technical
|
671044
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
8.5.4
|
Installation of switching devices and components
|
Technical
|
671045
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
8.5.5
|
Accessibility
|
Technical
|
671046
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
8.5.6
|
Barriers
|
Technical
|
671047
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
8.5.7
|
Direction of operation and indication of switching positions
|
Technical
|
671048
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
8.5.8
|
Indicator lights and push-buttons
|
Technical
|
671049
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
8.6.1
|
Internal electrical circuits and connections - Main circuits
|
Technical
|
671050
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
8.6.2
|
Auxiliary circuits
|
Technical
|
671051
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
8.6.3
|
Bare and insulated conductors
|
Technical
|
671052
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
8.6.4
|
Selection and installation of non-protected live conductors to reduce the possibility of short-circuits
|
Technical
|
671053
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
8.6.5
|
Identification of the conductors of main and auxiliary circuits
|
Technical
|
671054
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
8.6.6
|
Identification of the protective conductor (PE, PEN) and of the neutral conductor (N) of the main circuits
|
Technical
|
671055
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
8.7
|
Cooling
|
Technical
|
671056
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
8.8
|
Terminals for external conductors
|
Technical
|
671057
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
9.1.1
|
Performance requirements - Dielectric properties - General
|
Technical
|
671058
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
9.1.2
|
Power-frequency withstand voltage
|
Technical
|
671059
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
9.1.3
|
Impulse withstand voltage
|
Technical
|
671060
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
9.1.4
|
Protection of surge protective devices
|
Technical
|
671061
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
9.2
|
Temperature rise limits
|
Technical
|
671062
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
9.3.1
|
Short-circuit protection and short-circuit withstand strength - General
|
Technical
|
671063
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
9.3.2
|
Information concerning short-circuit withstand strength
|
Technical
|
671064
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
9.3.3
|
Relationship between peak current and short-time current
|
Technical
|
671065
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
9.3.4
|
Co-ordination of protective devices
|
Technical
|
671066
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
9.4
|
Electromagnetic compatibility (EMC)
|
Technical
|
671067
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
10.1
|
Design verification - General
|
Technical
|
671068
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
10.2.1
|
Strength of materials and parts
|
Technical
|
671069
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
10.2.2
|
Resistance to corrosion
|
Technical
|
671070
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
10.2.3
|
Properties of insulating materials
|
Technical
|
671071
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
10.2.4
|
Resistance to ultra-violet (UV) radiation
|
Technical
|
671072
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
10.2.5
|
Lifting
|
Technical
|
671073
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
10.2.6
|
Mechanical impact
|
Technical
|
671074
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
10.2.7
|
Marking
|
Technical
|
671075
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
10.3
|
Degree of protection of ASSEMBLIES
|
Technical
|
671076
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
10.4
|
Clearances and creepage distances
|
Technical
|
671077
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
10.5.1
|
Protection against electric shock and integrity of protective circuits - Effectiveness of the protective circuit
|
Technical
|
671078
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
10.5.2
|
Effective earth continuity between the exposed conductive parts of the ASSEMBLY and the protective circuit
|
Technical
|
671079
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
10.5.3
|
Short-circuit withstand strength of the protective circuit
|
Technical
|
671080
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
10.6.1
|
Incorporation of switching devices and components - General
|
Technical
|
671081
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
10.6.2
|
Electromagnetic compatibility
|
Technical
|
671082
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
10.7
|
Internal electrical circuits and connections
|
Technical
|
671083
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
10.8
|
Terminals for external conductors
|
Technical
|
671084
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
10.9.1
|
Dielectric properties - General
|
Technical
|
671085
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
10.9.2
|
Power-frequency withstand voltage
|
Technical
|
671086
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
10.9.3
|
Impulse withstand voltage
|
Technical
|
671087
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
10.9.4
|
Testing of enclosures made of insulating material
|
Technical
|
671088
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
10.9.5
|
External operating handles of insulating material
|
Technical
|
671089
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
10.10.1
|
Verification of temperature rise - General
|
Technical
|
671090
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
10.10.2
|
Verification by testing
|
Technical
|
671091
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
10.10.3
|
Derivation of ratings for similar variants
|
Technical
|
671092
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
10.10.4
|
Verification assessment
|
Technical
|
671093
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
10.11.1
|
Short-circuit withstand strength - General
|
Technical
|
671094
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
10.11.2
|
Circuits of ASSEMBLIES which are exempted from the verification of the shortcircuit withstand strength
|
Technical
|
671095
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
10.11.3
|
Verification by comparison with a reference design - Utilising a check list
|
Technical
|
671096
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
10.11.4
|
Verification by comparison with a reference design - Utilising calculation
|
Technical
|
673097
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
10.11.5
|
Verification by test
|
Testing
|
671098
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
10.12
|
Electromagnetic compatibility (EMC)
|
Technical
|
671099
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
10.13
|
Mechanical operation
|
Technical
|
671100
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
11.1
|
Routine verification - General
|
Technical
|
671101
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
11.2
|
Degree of protection of enclosures
|
Technical
|
671102
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
11.3
|
Clearances and creepage distances
|
Technical
|
671103
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
11.4
|
Protection against electric shock and integrity of protective circuits
|
Technical
|
671104
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
11.5
|
Incorporation of built-in components
|
Technical
|
671105
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
11.6
|
Internal electrical circuits and connections
|
Technical
|
671106
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
11.7
|
Terminals for external conductors
|
Technical
|
671107
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
11.8
|
Mechanical operation
|
Technical
|
671108
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
11.9
|
Dielectric properties
|
Technical
|
671109
|
AS/ NZS 61439.1:2016 Low-voltage switchgear and controlgear assemblies
|
11.1
|
Wiring, operational performance and function
|
Technical
|
511171
|
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection
|
14.2
|
Solid obstacles
|
Technical
|
121150
|
Electricity Safety (General) Regulations 2019
|
202(a)
|
General wiring methods for electrical installations - Regulations
|
Technical
|
121151
|
Electricity Safety (General) Regulations 2019
|
202(b)
|
General wiring methods for electrical installations - Wiring Rules
|
Technical
|
121152
|
Electricity Safety (General) Regulations 2019
|
202(c)
|
General wiring methods for electrical installations - AS 2067
|
Technical
|
121153
|
Electricity Safety (General) Regulations 2019
|
202(d)
|
General wiring methods for electrical installations - AS/NZS 7000
|
Technical
|
121154
|
Electricity Safety (General) Regulations 2019
|
203(1)
|
Electrical installations installed before commencement of these regulations
|
Technical
|
121155
|
Electricity Safety (General) Regulations 2019
|
204(1)
|
Design and installation method - part 1 solution
|
Technical
|
121156
|
Electricity Safety (General) Regulations 2019
|
204(2)
|
Design and installation method - part 1 solution
|
Technical
|
122156
|
Electricity Safety (General) Regulations 2019
|
204(2)
|
Design and installation method - part 1 solution
|
Unsafe
|
121157
|
Electricity Safety (General) Regulations 2019
|
204(3)
|
Design and installation method - part 1 solution
|
Technical
|
121158
|
Electricity Safety (General) Regulations 2019
|
204(4)
|
Design and installation method - part 1 solution
|
Technical
|
121159
|
Electricity Safety (General) Regulations 2019
|
204(5)
|
Design and installation method - part 1 solution
|
Technical
|
121160
|
Electricity Safety (General) Regulations 2019
|
204(6)(a)
|
Design and installation method - part 1 solution
|
Technical
|
121161
|
Electricity Safety (General) Regulations 2019
|
204(6)(b)
|
Design and installation method - part 1 solution
|
Technical
|
121162
|
Electricity Safety (General) Regulations 2019
|
204(7)
|
Design and installation method - part 1 solution
|
Technical
|
121163
|
Electricity Safety (General) Regulations 2019
|
204(8)
|
Design and installation method - part 1 solution
|
Technical
|
121164
|
Electricity Safety (General) Regulations 2019
|
204(9)
|
Design and installation method - part 1 solution
|
Technical
|
121165
|
Electricity Safety (General) Regulations 2019
|
205
|
High voltage electrical installation work - verification of design
|
Technical
|
121166
|
Electricity Safety (General) Regulations 2019
|
206
|
Electrical installation work in patient areas
|
Technical
|
121167
|
Electricity Safety (General) Regulations 2019
|
207
|
Control of electrical installations
|
Technical
|
121168
|
Electricity Safety (General) Regulations 2019
|
208
|
Earthing systems
|
Technical
|
121169
|
Electricity Safety (General) Regulations 2019
|
209
|
Main Earthing conductor
|
Technical
|
121170
|
Electricity Safety (General) Regulations 2019
|
210
|
Connection of consumer billing meters and supply network neutral conductors
|
Technical
|
121171
|
Electricity Safety (General) Regulations 2019
|
211
|
Premises with consumer electricity generation systems
|
Technical
|
121172
|
Electricity Safety (General) Regulations 2019
|
212
|
Battery Systems
|
Technical
|
121173
|
Electricity Safety (General) Regulations 2019
|
213
|
Electric security fences
|
Technical
|
121174
|
Electricity Safety (General) Regulations 2019
|
214
|
Electricity supplies-construction and demolition sites
|
Technical
|
121175
|
Electricity Safety (General) Regulations 2019
|
215
|
Multiple occupancy buildings and subdivisions
|
Technical
|
121176
|
Electricity Safety (General) Regulations 2019
|
216
|
Wiring found passing through individual occupier's portions
|
Technical
|
121177
|
Electricity Safety (General) Regulations 2019
|
217
|
Wiring passing through other allotments
|
Technical
|
121178
|
Electricity Safety (General) Regulations 2019
|
218(1)
|
Properties with multiple points of supply
|
Technical
|
121179
|
Electricity Safety (General) Regulations 2019
|
218(2)
|
Properties with multiple points of supply
|
Technical
|
121180
|
Electricity Safety (General) Regulations 2019
|
218(3)
|
Properties with multiple points of supply
|
Technical
|
121181
|
Electricity Safety (General) Regulations 2019
|
218(4)
|
Properties with multiple points of supply
|
Technical
|
121182
|
Electricity Safety (General) Regulations 2019
|
218(5)
|
Properties with multiple points of supply
|
Technical
|
121183
|
Electricity Safety (General) Regulations 2019
|
218(7)
|
Properties with multiple points of supply
|
Technical
|
121184
|
Electricity Safety (General) Regulations 2019
|
219(1)
|
Route of underground lines - record of underground route
|
Technical
|
121185
|
Electricity Safety (General) Regulations 2019
|
219(2)
|
Route of underground lines - ensure record of underground route is fixed per ES(G)R 219(a)
|
Technical
|
121186
|
Electricity Safety (General) Regulations 2019
|
219(3)
|
Route of underground lines - record of underground route margin of error
|
Technical
|
121187
|
Electricity Safety (General) Regulations 2019
|
219(4)
|
Route of underground lines - underground electric line on public land
|
Technical
|
121188
|
Electricity Safety (General) Regulations 2019
|
220
|
Minimum depths of high voltage underground lines and underground lines on public land and on private land not owned or l eased by the owner of the line
|
Technical
|
121189
|
Electricity Safety (General) Regulations 2019
|
221
|
Mechanical protection of underground lines above the ground on public land and on private land not owned or leased by th e owner of the line
|
Technical
|
121190
|
Electricity Safety (General) Regulations 2019
|
222
|
Consumer's mains not to enter or cross contiguous property
|
Technical
|
121191
|
Electricity Safety (General) Regulations 2019
|
223
|
Protection of underground consumer's mains
|
Technical
|
121192
|
Electricity Safety (General) Regulations 2019
|
224
|
Construction of underground consumer's mains
|
Technical
|
121193
|
Electricity Safety (General) Regulations 2019
|
225
|
Mechanical cover of consumer's mains
|
Technical
|
121194
|
Electricity Safety (General) Regulations 2019
|
226
|
Construction of underground consumer's mains within a structure
|
Technical
|
121195
|
Electricity Safety (General) Regulations 2019
|
227
|
Construction of underground consumer's mains on the exterior of a building or structure
|
Technical
|
123196
|
Electricity Safety (General) Regulations 2019
|
228
|
Insulation resistance of underground consumer's mains
|
Testing
|
121197
|
Electricity Safety (General) Regulations 2019
|
229
|
Minimum distances between aerial lines and the ground or water
|
Technical
|
121198
|
Electricity Safety (General) Regulations 2019
|
230
|
Minimum distance from the ground for substations
|
Technical
|
121199
|
Electricity Safety (General) Regulations 2019
|
231
|
Construction and maintenance of poles and towers
|
Technical
|
121200
|
Electricity Safety (General) Regulations 2019
|
232
|
Marking of electric lines
|
Technical
|
122201
|
Electricity Safety (General) Regulations 2019
|
234
|
Private electric lines in hazardous bushfire risk areas
|
Unsafe
|
121202
|
Electricity Safety (General) Regulations 2019
|
235
|
Existing private service lines in hazardous bushfire risk areas-alternative compliance
|
Technical
|
121203
|
Electricity Safety (General) Regulations 2019
|
236
|
Private aerial lines-construction requirements
|
Technical
|
121204
|
Electricity Safety (General) Regulations 2019
|
237
|
Emergency restoration of private electric aerial lines in high bushfire risk areas
|
Technical
|
121205
|
Electricity Safety (General) Regulations 2019
|
238
|
High voltage conductors must not be supported along the facade of a building or structure
|
Technical
|
121206
|
Electricity Safety (General) Regulations 2019
|
239
|
Low voltage conductors supported along the facade of a building or structure
|
Technical
|
123207
|
Electricity Safety (General) Regulations 2019
|
240
|
General testing requirements for low voltage electrical installation work
|
Testing
|
123208
|
Electricity Safety (General) Regulations 2019
|
241
|
Testing of underground consumer's mains
|
Testing
|
123209
|
Electricity Safety (General) Regulations 2019
|
242
|
Testing of electrical installation work in patient areas
|
Testing
|
123210
|
Electricity Safety (General) Regulations 2019
|
243
|
Testing of photovoltaic arrays
|
Testing
|
123211
|
Electricity Safety (General) Regulations 2019
|
244
|
Testing of battery systems
|
Testing
|
123212
|
Electricity Safety (General) Regulations 2019
|
245
|
Testing of grid-connected inverter energy systems
|
Testing
|
123213
|
Electricity Safety (General) Regulations 2019
|
246
|
Testing of high voltage electrical installation work
|
Testing
|
123214
|
Electricity Safety (General) Regulations 2019
|
247
|
Persons authorised to carry out testing
|
Testing
|
123215
|
Electricity Safety (General) Regulations 2019
|
248
|
Results of testing of high-voltage electrical installation work
|
Testing
|
121216
|
Electricity Safety (General) Regulations 2019
|
249
|
Electrical installation work that must be inspected
|
Technical
|
121217
|
Electricity Safety (General) Regulations 2019
|
250
|
Inspection of prescribed electrical installation work
|
Technical
|
121218
|
Electricity Safety (General) Regulations 2019
|
251
|
Certificates of inspection
|
Technical
|
121219
|
Electricity Safety (General) Regulations 2019
|
252
|
Details to be accurate and legible - certificate of inspection
|
Technical
|
121220
|
Electricity Safety (General) Regulations 2019
|
253
|
Obligations of licensed electrical inspectors
|
Technical
|
121221
|
Electricity Safety (General) Regulations 2019
|
254
|
Notification of completion of certificate of inspection
|
Technical
|
121222
|
Electricity Safety (General) Regulations 2019
|
255
|
Licensed electrical inspectors must retain a copy of certificates of inspection
|
Technical
|
121223
|
Electricity Safety (General) Regulations 2019
|
256
|
Licensed electrical inspectors must not inspect their own work
|
Technical
|
121224
|
Electricity Safety (General) Regulations 2019
|
257
|
Licensed electrical inspectors must not inspect work if involved with the design of the work
|
Technical
|
121225
|
Electricity Safety (General) Regulations 2019
|
258
|
Installation work responsible person must not use an employee to inspect any work they are responsible for
|
Technical
|
121226
|
Electricity Safety (General) Regulations 2019
|
259
|
Notification of defects by inspectors
|
Technical
|
121227
|
Electricity Safety (General) Regulations 2019
|
260
|
Inspector must note defects on certificate of inspection
|
Technical
|
121228
|
Electricity Safety (General) Regulations 2019
|
261
|
Certificates of compliance
|
Technical
|
121229
|
Electricity Safety (General) Regulations 2019
|
262
|
Details to be accurate and legible - certificate of compliance
|
Technical
|
121230
|
Electricity Safety (General) Regulations 2019
|
263
|
Notification of completion of certificate of compliance
|
Technical
|
121231
|
Electricity Safety (General) Regulations 2019
|
264
|
Installation work responsible person must retain a copy of certificates of compliance
|
Technical
|
121232
|
Electricity Safety (General) Regulations 2019
|
301
|
Safety services
|
Technical
|
121233
|
Electricity Safety (General) Regulations 2019
|
302
|
Service lines and directly connected installations
|
Technical
|
121234
|
Electricity Safety (General) Regulations 2019
|
303
|
Installation of protective equipment
|
Technical
|
121235
|
Electricity Safety (General) Regulations 2019
|
304
|
Suppliers must ensure use of double insulation
|
Technical
|
121236
|
Electricity Safety (General) Regulations 2019
|
305
|
Supply of electricity to premises
|
Technical
|
121237
|
Electricity Safety (General) Regulations 2019
|
401
|
Reporting of serious electrical incidents
|
Technical
|
121238
|
Electricity Safety (General) Regulations 2019
|
402
|
Reporting of other electrical incidents-accidental contact and electric shock
|
Technical
|
121239
|
Electricity Safety (General) Regulations 2019
|
403
|
Reporting of serious electrical incidents-fire control authorities
|
Technical
|
121240
|
Electricity Safety (General) Regulations 2019
|
404
|
Reporting of electrical incidents (other than serious electrical incidents)-fire control authorities
|
Technical
|
121241
|
Electricity Safety (General) Regulations 2019
|
405
|
Records to be maintained
|
Technical
|
121242
|
Electricity Safety (General) Regulations 2019
|
501(1)
|
Safety standards-high voltage electrical installations
|
Technical
|
121243
|
Electricity Safety (General) Regulations 2019
|
501(2)
|
Safety standards-high voltage electrical installations
|
Technical
|
121244
|
Electricity Safety (General) Regulations 2019
|
501(3)
|
Safety standards-high voltage electrical installations
|
Technical
|
121245
|
Electricity Safety (General) Regulations 2019
|
502(1)
|
Safety standards- complex electrical installations
|
Technical
|
121246
|
Electricity Safety (General) Regulations 2019
|
502(2)
|
Safety standards- complex electrical installations
|
Technical
|
121247
|
Electricity Safety (General) Regulations 2019
|
502(3)
|
Safety standards- complex electrical installations
|
Technical
|
121248
|
Electricity Safety (General) Regulations 2019
|
504
|
Safety standard-embedded networks
|
Technical
|
121249
|
Electricity Safety (General) Regulations 2019
|
505
|
Safety standard-patient areas
|
Technical
|
121250
|
Electricity Safety (General) Regulations 2019
|
506
|
Private aerial line maintenance
|
Technical
|
121251
|
Electricity Safety (General) Regulations 2019
|
507
|
Supervision of apprentices carrying out electrical installation work
|
Technical
|
121252
|
Electricity Safety (General) Regulations 2019
|
509
|
Electrical installation work carried out on energised electrical equipment may only be permitted in particular circumsta nces
|
Technical
|
121253
|
Electricity Safety (General) Regulations 2019
|
510
|
Preliminary steps before carrying out electrical installation work on energised electrical equipment
|
Technical
|
121254
|
Electricity Safety (General) Regulations 2019
|
511
|
How electrical installation work is to be carried out on energised electrical equipment
|
Technical
|
122254
|
Electricity Safety (General) Regulations 2019
|
511
|
How electrical installation work is to be carried out on energised electrical equipment
|
Unsafe
|
681001
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
3.1
|
General
|
Technical
|
681002
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
3.2.3.2
|
Electrical Hazard - Decisive voltage classification
|
Technical
|
681003
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
3.2.3.3
|
Battery system prospective fault current/short circuit current
|
Technical
|
681004
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
3.2.4.2.2
|
Working distance
|
Technical
|
681005
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
3.2.4.2.3
|
Arcing time
|
Technical
|
681006
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
3.2.4.3
|
Multiplying factor
|
Technical
|
681007
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
3.2.4.4
|
Selecting personal protective equipment
|
Technical
|
681008
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
4.2.1
|
Pre-assembled integrated BESSs - Installation requirements - General
|
Technical
|
681009
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
4.2.2.1
|
Location - General
|
Technical
|
681010
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
4.2.2.2
|
Restricted locations
|
Technical
|
681011
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
4.2.3.1
|
Environmental requirements - General
|
Technical
|
681012
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
4.2.3.2
|
IP Rating
|
Technical
|
681013
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
4.2.4.1
|
Protection against spread of fire - General
|
Technical
|
681014
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
4.2.4.2
|
Barrier to habitable rooms
|
Technical
|
681015
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
4.2.5
|
Pre-assembled integrated BESS room requirements
|
Technical
|
681016
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
4.2.6
|
Seismic (earthquake) forces
|
Technical
|
681017
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
4.3.1.1
|
Electrical hazards - additional connections to the pre-assembled integrated BESS
|
Technical
|
681018
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
4.3.1.2
|
Grid port connections for the pre-assembled integrated BESS
|
Technical
|
681019
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
4.3.1.3.1
|
Earthing of the pre-assembled integrated BESS - General
|
Technical
|
681020
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
4.3.1.3.2
|
Earth fault protection - monitoring alarm
|
Technical
|
681021
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
4.3.2
|
Energy hazard - Arc flash
|
Technical
|
681022
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
4.3.3
|
Mechanical hazard
|
Technical
|
681023
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
4.3.4
|
Fire hazard
|
Technical
|
681024
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
4.3.5
|
Explosive gas hazard
|
Technical
|
681025
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
4.3.6
|
Chemical hazard
|
Technical
|
681026
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
4.3.7
|
Toxic fume hazard
|
Technical
|
681027
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
4.3.8
|
Battery alarm system
|
Technical
|
681028
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
4.4.1.1
|
Documentation - General
|
Technical
|
681029
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
4.4.1.2
|
System manual
|
Technical
|
681030
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
4.4.2.1
|
Verification - General
|
Technical
|
683031
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
4.4.2.2
|
Initial verification and visual inspection
|
Testing
|
681032
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
4.4.2.3
|
Alterations and repairs
|
Technical
|
683033
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
4.4.2.4
|
Testing
|
Testing
|
681034
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
4.4.3.1
|
Commissioning - General
|
Technical
|
681035
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
4.4.3.2
|
Induction
|
Technical
|
681036
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
5.1
|
General requirments for pre-assembled battery systems
|
Technical
|
681037
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
5.2.1
|
Installation requirements - General
|
Technical
|
681038
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
5.2.2.1
|
Location - General
|
Technical
|
681039
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
5.2.2.2
|
Restricted locations
|
Technical
|
681040
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
5.2.3.1
|
Environmental requirements - General
|
Technical
|
681041
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
5.2.3.2
|
IP Rating
|
Technical
|
681042
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
5.2.4.1
|
Protection against the spread of fire - General
|
Technical
|
681043
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
5.2.4.2
|
Barrier to habitable rooms
|
Technical
|
681044
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
5.2.5
|
Pre-assembled battery system room requirements
|
Technical
|
681045
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
5.2.6
|
Seismic (earthquake) forces
|
Technical
|
681046
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
5.3.1
|
Electrical hazards - General
|
Technical
|
681047
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
5.3.1.2.1
|
Overcurrent protection from battery system - General
|
Technical
|
681048
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
5.3.1.2.2
|
Requirements for circuit breakers
|
Technical
|
681049
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
5.3.1.2.3
|
Requirements for HRC fuses and holders
|
Technical
|
681050
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
5.3.1.2.5
|
Location of overcurrent protective devices
|
Technical
|
681051
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
5.3.1.3.1
|
Isolation of the pre-assembled battery system from the PCE - General
|
Technical
|
681052
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
5.3.1.3.2
|
Disconnection methods
|
Technical
|
681053
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
5.3.1.3.3
|
Requirements for battery system - Switch disconnector
|
Technical
|
681054
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
5.3.1.3.4
|
Additional requirements for an adjacent and physically separate disconnection device
|
Technical
|
681055
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
5.3.1.3.5
|
Additional requirements for a disconnection device integrated into PCE
|
Technical
|
681056
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
5.3.1.3.7
|
location of isolating devices
|
Technical
|
681057
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
5.3.1.3.8
|
BESS with multiple PCEs
|
Technical
|
681058
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
5.3.1.3.9
|
Parallel battery systems
|
Technical
|
681059
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
5.3.1.4.1
|
Battery system wiring to PCE - General
|
Technical
|
681060
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
5.3.1.4.2
|
Type of cable
|
Technical
|
681061
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
5.3.1.4.3
|
Mechanical protection
|
Technical
|
681062
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
5.3.1.4.4
|
Voltage drop
|
Technical
|
681063
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
5.3.1.4.5
|
Current-carrying capacity
|
Technical
|
681064
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
5.3.1.4.6
|
Parallel battery systems
|
Technical
|
681065
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
5.3.1.4.7
|
Protection from overcurrent from PCE
|
Technical
|
681066
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
5.3.1.5
|
Segregation of circuits
|
Technical
|
681067
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
5.3.1.6.1
|
Earthing of battery systems - General
|
Technical
|
681068
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
5.3.1.6.3
|
Earth connection requirements - Direct earthed
|
Technical
|
681069
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
5.3.1.6.4
|
Earth connection requirements - Resistive earthed
|
Technical
|
681070
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
5.3.1.6.5
|
Battery system connected to a non-separated PCE
|
Technical
|
681071
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
5.3.1.6.6
|
Battery system earth location
|
Technical
|
681072
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
5.3.1.6.7
|
Size of earth cable
|
Technical
|
681073
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
5.3.1.7.1
|
Earthing system - General
|
Technical
|
681074
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
5.3.1.7.2
|
Battery system not earthed - Bonding
|
Technical
|
681075
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
5.3.1.7.3
|
Battery system is directly earthed
|
Technical
|
681076
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
5.3.1.7.4
|
Battery system is resistively earthed
|
Technical
|
681077
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
5.3.1.8
|
Earth fault alarm - Monitoring alarm
|
Technical
|
681078
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
5.3.2
|
Energy hazard - Arc flash
|
Technical
|
681079
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
5.3.3
|
Mechanical hazard
|
Technical
|
681080
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
5.3.4
|
Fire hazard
|
Technical
|
681081
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
5.3.5
|
Explosive gas hazard
|
Technical
|
681082
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
5.3.6
|
Chemical hazard
|
Technical
|
681083
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
5.3.7
|
Toxic fume hazard
|
Technical
|
681084
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
5.3.8
|
Battery alarm system
|
Technical
|
681085
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
5.4.1.1
|
Documentation - General
|
Technical
|
681086
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
5.4.1.2
|
System manual
|
Technical
|
683087
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
5.4.2.1
|
Verification - General
|
Testing
|
683088
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
5.4.2.2
|
Initial verification and visual inspection
|
Testing
|
681089
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
5.4.2.3
|
Alterations and repairs
|
Technical
|
683090
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
5.4.2.4
|
Testing
|
Testing
|
681091
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
5.4.3.1
|
Commissioning - General
|
Technical
|
681092
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
5.4.3.2
|
Induction
|
Technical
|
681093
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.1
|
General
|
Technical
|
681094
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.2.2.1
|
Location - General
|
Technical
|
681095
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.2.2.2
|
Restricted locations
|
Technical
|
681096
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.2.3.1
|
Environmental requirements - General
|
Technical
|
681097
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.2.3.2
|
IP Rating
|
Technical
|
681098
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.2.4.1
|
Protection against the spread of fire - General
|
Technical
|
681099
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.2.4.2
|
Barrier to habitable rooms
|
Technical
|
681100
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.2.5.1
|
Battery system and BESS enclosure requirements - General
|
Technical
|
681101
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.2.5.2.1
|
Battery system enclosure - General
|
Technical
|
681102
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.2.5.2.2
|
Design, layout and construction
|
Technical
|
681103
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.2.5.3
|
BESS enclosure
|
Technical
|
681104
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.2.5.4
|
Installation of battery system enclosure
|
Technical
|
681105
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.2.6.1
|
Battery system room requirements - general
|
Technical
|
681106
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.2.6.2
|
Battery system room layout
|
Technical
|
681107
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.2.6.3
|
Location of luminaires
|
Technical
|
681108
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.2.7
|
Battery cell or module stands
|
Technical
|
681109
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.2.8
|
Seismic (earthquake) forces
|
Technical
|
681110
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.3.1.1
|
Electrical hazards - General
|
Technical
|
681111
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.3.1.2.1
|
Overcurrent protection from battery system - General
|
Technical
|
681112
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.3.1.2.2
|
Requirements for circuit breakers
|
Technical
|
681113
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.3.1.2.3
|
Requirements for HRC fuses and holders
|
Technical
|
681114
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.3.1.2.4
|
Battery systems that include overcurrent protection
|
Technical
|
681115
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.3.1.2.5
|
Location of overcurrent protective devices
|
Technical
|
681116
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.3.1.2.6
|
Battery systems not requiring a battery management system
|
Technical
|
681117
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.3.1.3.1
|
Isolation of the battery system from the PCE - General
|
Technical
|
681118
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.3.1.3.2
|
Disconnection methods
|
Technical
|
681119
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.3.1.3.3
|
Requirements for battery system - Switch disconnector
|
Technical
|
681120
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.3.1.3.4
|
Additional requirements for an adjacent and physically separate disconnection device
|
Technical
|
681121
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.3.1.3.5
|
Additional requirements for a disconnection device integrated into PCE
|
Technical
|
681122
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.3.1.3.6
|
Additional requirements for a disconnection device integrated into battery system
|
Technical
|
681123
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.3.1.3.7
|
location of isolating devices
|
Technical
|
681124
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.3.1.3.8
|
BESS with multiple PCEs
|
Technical
|
681125
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.3.1.3.9
|
Parallel battery systems
|
Technical
|
681126
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.3.1.3.10
|
Battery system: interconnection isolating requirements
|
Technical
|
681127
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.3.1.4.1
|
Screening from touch of live parts - General
|
Technical
|
681128
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.3.1.4.2
|
Battery systems operating at DVC-B level and DVC-C level
|
Technical
|
681129
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.3.1.4.3
|
Battery terminal systems and outgoing busbars
|
Technical
|
681130
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.3.1.4.4
|
Inter tier and inter row connections
|
Technical
|
681131
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.3.1.5.1
|
Battery system wiring to PCE - General
|
Technical
|
681132
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.3.1.5.2
|
Type of cable
|
Technical
|
681133
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.3.1.5.3
|
Mechanical protection
|
Technical
|
681134
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.3.1.5.4
|
Voltage drop
|
Technical
|
681135
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.3.1.5.5
|
Current-carrying capacity
|
Technical
|
681136
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.3.1.5.6
|
Parallel battery systems
|
Technical
|
681137
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.3.1.5.7
|
Protection from overcurrent from PCE
|
Technical
|
681138
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.3.1.6
|
Segregation of circuits
|
Technical
|
681139
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.3.1.7.1
|
Earthing of battery systems - General
|
Technical
|
681140
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.3.1.7.2
|
Floating/separated
|
Technical
|
681141
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.3.1.7.3
|
Earth connection requirements - Direct earthed
|
Technical
|
681142
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.3.1.7.4
|
Earth connection requirements - Resistive earthed
|
Technical
|
681143
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.3.1.7.5
|
Battery system connected to a non-separated PCE
|
Technical
|
681144
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.3.1.7.6
|
Battery system earth location
|
Technical
|
681145
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.3.1.7.7
|
Size of earth cable
|
Technical
|
681146
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.3.1.8.1
|
Earthing system - General
|
Technical
|
681147
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.3.1.8.2
|
Battery system not earthed - Bonding
|
Technical
|
681148
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.3.1.8.3
|
Battery system is directly earthed
|
Technical
|
681149
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.3.1.8.4
|
Battery system is resistively earthed
|
Technical
|
681150
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.3.1.9
|
Earth fault alarm - Monitoring alarm
|
Technical
|
681151
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.3.2.1
|
Energy hazard - Arc flash
|
Technical
|
681152
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.3.2.2
|
Arc flash risk assessment
|
Technical
|
681153
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.3.2.3
|
Battery system installed within a residential or domestic installation
|
Technical
|
681154
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.3.2.4
|
Battery system installed within a non domestic or non-residential installation
|
Technical
|
681155
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.3.2.5
|
Arc flash boundary
|
Technical
|
681156
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.3.3.1
|
Mechanical hazard - General
|
Technical
|
681157
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.3.3.2
|
Additional requirements for battery system and BESS enclosures
|
Technical
|
681158
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.3.3.3
|
Additional requirements for battery system rooms
|
Technical
|
681159
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.3.3.4
|
Moving parts
|
Technical
|
681160
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.3.4.1
|
Fire hazard - General
|
Technical
|
681161
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.3.4.2.1
|
Fire hazard level 1 installation requirements - Domestic and residential electrical installation
|
Technical
|
681162
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.3.4.2.2
|
Non-domestic and non-residential electrical installation
|
Technical
|
681163
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.3.4.3.1
|
Fire hazard level 2 installation requirements - Domestic and residential electrical installation
|
Technical
|
681164
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.3.4.3.2
|
Non-domestic and non-residential electrical installation
|
Technical
|
681165
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.3.4.4
|
Battery management system (BMS)
|
Technical
|
681166
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.3.4.5
|
Excess temperature
|
Technical
|
681167
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.3.4.6
|
Minimum temperature
|
Technical
|
681168
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.3.4.7
|
Overcurrent
|
Technical
|
681169
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.3.4.8
|
Overvoltage
|
Technical
|
681170
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.3.4.9
|
Over-discharge
|
Technical
|
681171
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.3.4.10
|
Protection against mechanical damage from external sources
|
Technical
|
681172
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.3.5.1
|
Explosive gas hazard - General
|
Technical
|
681173
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.3.5.2.1
|
Ventilation - General
|
Technical
|
681174
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.3.5.2.2
|
Sealed valve regulated lead acid cells
|
Technical
|
681175
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.3.5.2.3
|
Rate of ventilation (lead acid)
|
Technical
|
681176
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.3.5.2.4
|
Charging rate
|
Technical
|
681177
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.3.5.2.5
|
Method of ventilation - Natural ventilation
|
Technical
|
681178
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.3.5.2.6
|
Method of ventilation - Mechanical ventilation
|
Technical
|
681179
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.3.5.2.7
|
Arrangement of ventilation
|
Technical
|
681180
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.3.5.2.8
|
Other battery system chemistries
|
Technical
|
681181
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.3.5.3
|
Additional requirements for battery system enclosures
|
Technical
|
681182
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.3.5.4
|
Additional requirements for installation of battery system enclosures or BESS enclosures
|
Technical
|
681183
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.3.5.5
|
Additional requirements for battery system rooms
|
Technical
|
681184
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.3.6.1
|
Chemical hazard - General
|
Technical
|
681185
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.3.6.2
|
Puncturing
|
Technical
|
681186
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.3.6.3
|
Containment
|
Technical
|
681187
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.3.6.4
|
Additional requirements for enclosures and rooms
|
Technical
|
681188
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.3.7.1
|
Toxic fume hazard - General
|
Technical
|
681189
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.3.7.2
|
Battery system rooms and enclosures requirements
|
Technical
|
681190
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.3.8
|
Battery alarm system
|
Technical
|
681191
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.4.1.1
|
Documentation - General
|
Technical
|
681192
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.4.1.2
|
System manual
|
Technical
|
683193
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.4.2.1
|
Verification - General
|
Testing
|
683194
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.4.2.2
|
Initial verification and visual inspection
|
Testing
|
681195
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.4.2.3
|
Alterations and repairs
|
Technical
|
683196
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.4.2.4
|
Testing
|
Testing
|
681197
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.4.3.1
|
Commissioning - General
|
Technical
|
681198
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
6.4.3.2
|
Induction
|
Technical
|
681199
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
7.1
|
Labels and safety signage - General
|
Technical
|
681200
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
7.2
|
Requirements for signs and labels
|
Technical
|
681201
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
7.3
|
Battery type general labelling
|
Technical
|
681202
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
7.4
|
Signs for battery system location
|
Technical
|
681203
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
7.5
|
Restricted access
|
Technical
|
681204
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
7.6
|
Voltage and current
|
Technical
|
681205
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
7.7
|
Safety data sheet (SDS)
|
Technical
|
681206
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
7.8
|
Explosive gas hazard
|
Technical
|
681207
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
7.9
|
Toxic fume hazard
|
Technical
|
681208
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
7.1
|
Chemical hazard
|
Technical
|
681209
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
7.11
|
Arc flash
|
Technical
|
681210
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
7.12.1
|
Disconnection devices General
|
Technical
|
681211
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
7.12.2
|
Battery system isolation device
|
Technical
|
681212
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
7.12.3
|
Multiple isolation device
|
Technical
|
681213
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
7.12.4
|
Disconnectors for DVC-B and DVC-C systems
|
Technical
|
681214
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
7.13.1
|
Overcurrent devices - General
|
Technical
|
681215
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
7.13.2
|
Multiple overcurrent devices
|
Technical
|
681216
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
7.13.3
|
Fuse holders
|
Technical
|
681217
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
7.14
|
Battery system cables
|
Technical
|
681218
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
7.15
|
Segregation of circuits
|
Technical
|
681219
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
7.16
|
Shutdown procedure
|
Technical
|
681220
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
7.17
|
Battery labelling
|
Technical
|
681221
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
7.18
|
Other equipment labelling
|
Technical
|
681222
|
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
|
7.19
|
Spill containment
|
Technical
|
122151
|
Electricity Safety (General) Regulations 2019
|
202(b)
|
General wiring methods for electrical installations - Wiring Rules
|
Unsafe
|
122154
|
Electricity Safety (General) Regulations 2019
|
203(1)
|
Electrical installations installed before commencement of these regulations
|
Unsafe
|
211918
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
4.1.5
|
Electrical equipment - Air extraction systems
|
Technical
|
211919
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
6.3.4.5.1
|
SWIMMING POOLS, PADDLING POOLS AND SPA POOLS OR TUBS - Selection and installation of electrical equipment - Luminaires, appliances and other electrical equipment - General
|
Technical
|
211920
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
6.3.4.5.2
|
SWIMMING POOLS, PADDLING POOLS AND SPA POOLS OR TUBS -Selection and installation of electrical equipment - Zone 0 Lumina ires
|
Technical
|
211921
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
6.3.4.5.3
|
SWIMMING POOLS, PADDLING POOLS AND SPA POOLS OR TUBS - Selection and installation of electrical equipment - Zone 0 Appli ances and other electrical equipment
|
Technical
|
211922
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
6.3.4.5.4
|
SWIMMING POOLS, PADDLING POOLS AND SPA POOLS OR TUBS - Selection and installation of electrical equipment - Zone 1 Lumin aires, appliances and other electrical equipment
|
Technical
|
211923
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
6.3.4.5.5
|
SWIMMING POOLS, PADDLING POOLS AND SPA POOLS OR TUBS - Selection and installation of electrical equipment - Zone 2 Lumin aires, appliances and other electrical equipment
|
Technical
|
211924
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
6.4.4.5.1
|
FOUNTAINS AND WATER FEATURES - Selection and installation of electrical equipment - Luminaires, appliances and other ele ctrical equipment - General
|
Technical
|
211925
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
6.4.4.5.2
|
FOUNTAINS AND WATER FEATURES - Selection and installation of electrical equipment - Zone 0 Luminaires
|
Technical
|
211926
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
6.4.4.5.3
|
FOUNTAINS AND WATER FEATURES - Selection and installation of electrical equipment - Zone 0 Appliances and other electric al equipment
|
Technical
|
211927
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
6.4.4.5.4
|
FOUNTAINS AND WATER FEATURES - Selection and installation of electrical equipment - Zone1 Luminaires, appliances and oth er electrical equipment
|
Technical
|
841079
|
AS/NZS 3012:2019 +A1 Electrical installations - Construction and demolition sites
|
3.3.1
|
CONSTRUCTION WIRING AND TRANSPORTABLE STRUCTURES - Initial verification
|
Technical
|
841080
|
AS/NZS 3012:2019 +A1 Electrical installations - Construction and demolition sites
|
3.3.2
|
CONSTRUCTION WIRING AND TRANSPORTABLE STRUCTURES - Periodic verification
|
Technical
|
841081
|
AS/NZS 3012:2019 +A1 Electrical installations - Construction and demolition sites
|
3.4
|
VERIFICATION - RCDS
|
Testing
|
841083
|
AS/NZS 3012:2019 +A1 Electrical installations - Construction and demolition sites
|
3.5.2
|
VERIFICATION - Protective earthing continuity
|
Testing
|
841084
|
AS/NZS 3012:2019 +A1 Electrical installations - Construction and demolition sites
|
3.5.3
|
VERIFICATION - Insulation resistance or leakage current
|
Testing
|
841085
|
AS/NZS 3012:2019 +A1 Electrical installations - Construction and demolition sites
|
3.5.4
|
VERIFICATION - Arc welding equipment
|
Testing
|
841086
|
AS/NZS 3012:2019 +A1 Electrical installations - Construction and demolition sites
|
3.6
|
CONNECTION BETWEEN GENERATOR WINDINGS, FRAME AND EQUIPOTENTIAL BONDING SYSTEM
|
Testing
|
841087
|
AS/NZS 3012:2019 +A1 Electrical installations - Construction and demolition sites
|
3.7.1
|
ACTIONS RESULTING FROM INSPECTION AND TEST - Construction wiring
|
Technical
|
841088
|
AS/NZS 3012:2019 +A1 Electrical installations - Construction and demolition sites
|
3.7.2
|
ACTIONS RESULTING FROM INSPECTION AND TEST - Non-compliant equipment
|
Technical
|
841089
|
AS/NZS 3012:2019 +A1 Electrical installations - Construction and demolition sites
|
3.7.3
|
ACTIONS RESULTING FROM INSPECTION AND TEST - Compliant equipment
|
Technical
|
841090
|
AS/NZS 3012:2019 +A1 Electrical installations - Construction and demolition sites
|
3.8
|
PORTABLE GENERATOR SETS AND INVERTERS
|
Technical
|
841091
|
AS/NZS 3012:2019 +A1 Electrical installations - Construction and demolition sites
|
3.9
|
DOCUMENTATION
|
Technical
|
211163
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
2.6.3.2.3
|
Additional protection by residual current devices - Non-domestic and non-residential installations
|
Technical
|
211557
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
5.4.1.1
|
EARTHING OF EQUIPMENT - General - Exposed conductive parts
|
Technical
|
211568
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
5.4.8
|
EARTHING OF EQUIPMENT - Variable frequency devices
|
Technical
|
211666
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
6.4.3.2.1
|
FOUNTAINS AND WATER FEATURES - Protection against electric shock - Application of protective measures against electric s hock - Supply
|
Technical
|
211682
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
6.5.3.3
|
SAUNAS - Protection against electric shock - Additional protection by RCD
|
Technical
|
211791
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
7.3.3.1
|
ELECTRICITY GENERATION SYSTEMS - Control - Basic protection and fault protection
|
Technical
|
213902
|
AS/NZS 3000:2018 +A1+A2 Electrical Installations
|
8.3.6.3
|
TESTING - Insulation resistance - Results
|
Testing
|
842014
|
AS/NZS 3012:2019 +A1 Electrical installations - Construction and demolition sites
|
2.3.2.1
|
SWITCHBOARDS - Switchboard construction - General requirements
|
Unsafe
|
841025
|
AS/NZS 3012:2019 +A1 Electrical installations - Construction and demolition sites
|
2.4.6.1
|
CONTROL AND PROTECTION - Additional protection - Final sub-circuits of construction wiring
|
Technical
|
841026
|
AS/NZS 3012:2019 +A1 Electrical installations - Construction and demolition sites
|
2.4.6.2
|
CONTROL AND PROTECTION - Appliances, luminaires and other electrical equipment supplied by final subcircuits of permanen t installation wiring
|
Technical
|
611110
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
4.2.4
|
Current limiting of the incoming supply
|
Technical
|
611111
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
4.2.5
|
Enclosure of live parts
|
Technical
|
611112
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
4.2.6
|
Marking
|
Technical
|
611113
|
AS/NZS 3010:2017 +A1Electrical installations - Generating sets
|
4.2.7
|
Control of socket outlets
|
Technical
|
111022
|
Electricity Safety Act 1998
|
38
|
Electrical workers
|
Unsafe
|
111023
|
Electricity Safety Act 1998
|
38
|
Electrical workers
|
Technical
|
111024
|
Electricity Safety Act 1998
|
45(3)
|
Inspection of electrical installation work
|
Technical
|
111025
|
Electricity Safety Act 1998
|
45(4)
|
Inspection of electrical installation work - certificate of inspection obligations
|
Technical
|